MAURY USCG vessel records Sign in
← All vessels

TWILIGHT

TWILIGHT is a passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1985, most recently in March 2026, along with 114 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 12 March 2026.

Built
Not recorded
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI6641
Flag
UNITED STATES
367048520
Maury page id
psix-59644

Inspections, by type

…with no type recorded2
Years with a record 39 calendar years (1985–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.5 ft × 12.5 ft × 3.1 ft
Registered tonnagegross 9 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNot recorded
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWORTON, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Gross Ton
6 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI6641MMSI 367048520 · active · compulsorily equipped · granted 16 March 2026, expires 14 March 2036
WSJ5285MMSI 367048520 · expired · compulsorily equipped · granted 9 June 2005, cancelled 8 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 69

12 March 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8326792
13 March 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8090055
3 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8073812
14 March 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7879715
9 March 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7651990
10 March 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7409311
8 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7393509
6 December 2021 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7380331
25 March 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7164773
1 April 2020 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6944546
12 March 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6921396
3 January 2020 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6882123
14 March 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6643127
24 January 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6617925
15 March 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6392727
16 March 2017 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6085960
12 January 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6081069
14 March 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5833172
21 March 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4824691
8 February 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4244774
29 August 2011 Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4131731
26 March 2010 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3711863
3 February 2010 Hull Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3675547
23 March 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3438623
2 June 2008 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3225239
10 April 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3181310
15 October 2007 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3080530
22 March 2007 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2892744
15 February 2007 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2870744
15 March 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2610253
10 December 2005 Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 2553297
28 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2329282
25 January 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2280370
30 March 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2033853
1 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1599516
8 January 2002 Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1476587
21 March 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1468629
20 October 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1468605
26 April 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1379053
30 March 1999 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1126265
11 January 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809556
6 May 1998 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1125915
18 April 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792687
19 March 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1372216
19 March 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422996
4 September 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1411530
4 April 1997 Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1380838
1 April 1996 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1077728
7 September 1995 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448706
30 March 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 861368
6 April 1994 Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1025702
6 April 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1171096
15 April 1993 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1140074
9 March 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1146834
6 October 1992 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1257675
10 August 1992 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1269118
24 June 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 958353
30 March 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1470626
17 March 1992 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 954558
2 April 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1217146
25 January 1991 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1223218
23 April 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 920946
28 March 1990 Drydock Extension · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1214550
30 March 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1350298
30 November 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1035541
23 July 1987 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1029595
23 July 1987 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1348359
1 April 1986 Initial Certification · Credit Drydock
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1306920
10 May 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1289717

Deficiency record · 114

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 March 2025 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel operator was unable to provide training log.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2025
Resolved 12 March 2026
Resolution: Verified during Annual Inspection
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 March 2025 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. Life float did not have person capacity marked properly.
Action required: 10 - Deficiency Rectified
Due 13 March 2025
Resolved 13 March 2025
Resolution: Operator properly marked life floats in presents of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2024 Resolved
46 CFR 176.808(c) Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Vessel's ring buoy light had an expired battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2024
Resolution: Owner purchased new waterlight batteries.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Bilge high level alarm in engine compartment is inop. 46CFR182.530(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2023
Resolution: Bilge High level has been fixed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 February 2022 Resolved
An internal Structural examination conducted in compliance with 176.600 and consists of a complete examinsation of the vessel's main strength members. The keel from the stem aft approximately 12' was found wasted. Submit proposal to repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2022
Resolution: repairs have been made to the vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 February 2022 Resolved
An internal Structural examination conducted in compliance with 176.600 and consists of a complete examinsation of the vessel's main strength members. Beam supporting overhead of steering compartment was found rotten and needing replacement. Submit proposal to repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2022
Resolution: Repairs to vessel have been made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2020 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Deficiency: Upon inspection, a steady leak in engine's wet exhaust was observed. Provide written specifications describing the details of any repairs (repair proposal) to address deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2020
Resolved 4 May 2020
Resolution: provided the attending MI with photo of part replacement and video of wet exhaust operation; All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required. Deficiency: Vessel is missing (1) 2:A fire extinguisher. Provide proof of evidence that meets the minimum requirement for vessel's portable extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2020
Resolved 1 April 2020
Resolution: Verified the purchase (receipt) and mounting (photos) of new fire extinguisher in the vessel; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2020 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Deficiency: No alcohol test device were available during the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 4 May 2020
Resolution: Provided proof of alcohol test kits (photo); All sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2020 Resolved
Employers must ensure that they and their crewmembers meet the requirements for required Chemical testing. Deficiency: Vessel failed to provide proof of compliance with Chemical testing requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 4 May 2020
Resolution: Provided proof of enrollment from Health Enhancement Center (copy of letter); All sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 March 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and publications. Deficiency: Coast Pilot and Light List out of date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 4 May 2020
Resolution: Provided proof of having up-to-date required publications (photos); all sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2019 Resolved
Alcohol test strips onboard are expired. Replace with current testin strips/device.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 4 May 2020
Resolution: Provided proof of alcohol test kits (photo); All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 March 2019 Resolved
Vessel must have at least 03 2.5gal fire buckets onboard. Vessel only had 02. Buckets must have lanyard and stenciled properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Vessel is Old T and met the hand pump requirement; no buckets is required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2019 Resolved
Replace/Renew wasted grabline on lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2020
Resolved 13 March 2020
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2018 Resolved
Lifering waterlight battery expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2018
Resolved 27 March 2018
Resolution: Vessel provided non-expired battery.
Lifesaving › Lifefloat › Serviceable
Issued 15 March 2018 Resolved
Repair cracked and worn areas on lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2018
Resolved 27 March 2018
Resolution: Lifefloat was properly repaired.
Documentation › Certificates/Documents › FCC SSL
Issued 15 March 2018 Resolved
FCC Station Liicense not onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2018
Resolved 27 March 2018
Resolution: Vessel rep. provided copy of current FCC Station License.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 March 2017 Resolved
Vessel's high water alarm inoperable. Ensure proper operation of bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 May 2017
Resolution: Verified proper operation of hi-water alarm.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 March 2017 Resolved
Provide service report attesting to installation and performance of the fixed fire fighting system in engine compartment.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 31 March 2017
Resolution: Verified proper servicing of fire boy system.
Lifesaving › Lifefloat › Serviceable
Issued 16 March 2017 Resolved
Lifefloat platform attachement point damaged exposing foam floatation material. Repair/renew as needed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 31 March 2017
Resolution: Verified repair of damaged life float.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2017 Resolved
Make permanent seperation of adult and child life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 31 March 2017
Resolution: Verified proper seperation of lifejackets.
Documentation › Certificates/Documents › FCC SSL
Issued 14 March 2016 Resolved
FCC Station License expired. Provide new license on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 7 August 2017
Resolution: Cleared by Attending marine inspector.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 March 2016 Resolved
Compass light not operating. Repair/replace to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 7 August 2017
Resolution: Cleared by attending marine inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 28 March 2014 Resolved
Provide for inspection 11 Adult Lifejackets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Resolution: 11 new lifejackets were labeled with vessel name and onboard ready for inspection.
Lifesaving › Lifebuoys › Size
Issued 28 March 2014 Resolved
Replace Lifebouy with 24 inch lifebouy.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Resolution: A 24 inch orange lifebouy was purchased, labeled with vessel name and solas tape ready for insepction.
Lifesaving › Lifefloat › Markings
Issued 28 March 2014 Resolved
Repair lifefloat with approved repair kit and relabel.
Condition: Improper/Lack of Maintenance
Due 10 April 2014
Resolved 26 June 2014
Resolution: Verified pictures of painted repairs on lifefloat, all sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 March 2010 Resolved
Company has no record of completed background checks on safety sensitive employees who worked in the marine industry.
Due 6 April 2010
Resolved 6 April 2010
Resolution: [name withheld] has submitted all required documentation required for compliance at this present time.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 26 March 2010 Resolved
Employer has a way to be tested without having to maintain testing kits on vessel.
Due 6 April 2010
Resolved 6 April 2010
Resolution: Company has made arrangements to have testing done by community facility.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 26 March 2010 Resolved
Employer needs to file the annual MIS report information is provided by Health Enhancement Consortium.
Due 6 April 2010
Resolved 6 April 2010
Resolution: MIS report submitted to Headquarters.
Engineering › Sea-water System (primary cooling) › Valve
Issued 3 February 2010 Resolved
Replace ball valve for engine cooling system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2010
Resolution: Ball valve replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 3 February 2010 Resolved
Submit repair proposal for repair of the two knees portside aft as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2010
Resolution: Knees repaired iaw the proposal.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 3 February 2010 Resolved
Submit repair proposal for the dutchman starboard side forward as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2010
Resolution: Wasted dutchman replaced with good wood.
Documentation › Certificates/Documents › FCC SSL
Issued 23 March 2009 Resolved
FCC Safety Certificate expired. Show proof that an FCC representative has serviced radio and issued a current FCC Safety Certificate within 30 days to the satisfaction of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 3 April 2009
Resolution: A valid FCC Safety Certificate was obtained and the radio was serviced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 March 2009 Resolved
Deck rail doesn't extend across the stern of the vessel. Deck rail is also missing from starboard side amidships. Extend deck rail across the stern & starboard side amidships prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2009
Resolution: Deck rail extended across the stern and starboard side amidships.
Navigation › Piloting/Steering › US Coast Pilot
Issued 23 March 2009 Resolved
Old T regulations not available on vessel. Obtain a copy of Old T regulations and maintain on board within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 3 April 2009
Resolution: Vessel was unable to locate a copy of Old T regualtions, obtain a current edition of New T regs.
Engineering › Steering Gear System › Rudder
Issued 10 April 2008 Resolved
Vessel has excessive flow of water from the rudder post due to inadequate packing.
Condition: Improper/Lack of Maintenance
Due 10 April 2008
Resolved 10 April 2008
Resolution: Vessel personnel installed and tightened new packing in rudder post.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 March 2007 Resolved
Required to have drug/alcohol test kit on board or arrangements with local facility with two hour response, 24 hours a day, 365 days a testing.
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 29 March 2007
Resolution: Rcvd copy fm company that meets the requirements.
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 March 2007 Resolved
Have U.S. Coast Pilot pub on board.
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 29 March 2007
Resolution: Had copy of download section of U.S. Coast Pilot on board for operating area.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 March 2007 Resolved
Replace existing life ring float light line with 18' buoyant line.
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 30 April 2007
Resolution: Correct lenth and type of line was on life ring.
Lifesaving › Lifefloat › Painter
Issued 22 March 2007 Resolved
Replace life float existing painter w/100' buoyant dark line.
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 30 April 2007
Resolution: Visited vsl on 30 April 07 and view that correct line was in place.
Engineering › Bilge Water Management System › Pump
Issued 22 March 2007 Resolved
Replace rule 1500 bilge pumps with UL approved bilge pumps
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 30 April 2007
Resolution: Visited vsl on 30 April 2007 and viewed UL approved 2000 bilge pumps.
Engineering › Bilge Water Management System › Valve
Issued 22 March 2007 Resolved
Install valves at overboard thru hull fittings on both bilge pumps.
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 30 April 2007
Resolution: Visited vsl on 30 April 07 and viewed valves at thru hull fittings.
Engineering › Fuel Oil Service System
Issued 30 March 2004 Resolved
Label emergency fuel shut off.
Due 4 May 2004
Resolved 4 May 2004
Resolution: Shut-off labeled.
Electrical › Electrical Distribution System (service)
Issued 30 March 2004 Resolved
Install cover where electrical gauge has been removed.
Due 29 April 2004
Resolved 4 May 2004
Resolution: Cover installed.
Communications › Alarms/Indicators
Issued 1 April 2002 Resolved
PROVIDE VISUAL INDICATING LIGHT FOR HIGH WATER ALARM. LEGACY COMPONENT DESC: Bilge Alarm
Due 1 May 2002
Resolved 31 March 2003
Resolution: VISUAL INDICATING LIGHT INSTALLED FOR HIGH WATER ALARM.
Construction/Loadline › Penetrations
Issued 8 January 2002 Resolved
PLUG TWO THRU HOLES IN ENGINE COMPARTMENT. ITEM TO BE COMPLETED PRIOR TO REFLOATING VESSEL. LEGACY COMPONENT DESC: Bottom Plug
Due 23 March 2002
Resolved 8 March 2002
Construction/Loadline
Issued 20 October 2000 Resolved
REPAIR AREAS OF ROT ON CABIN TOP AND AROUND WINDOWS.
Condition: Unknown
Due 1 March 2001
Resolved 11 January 2002
Construction/Loadline
Issued 20 October 2000 Resolved
RENEW ROTTED DECK PANELS.
Condition: Unknown
Due 1 March 2001
Resolved 11 January 2002
Construction/Loadline
Issued 20 October 2000 Resolved
REPAIR FWD TOE BOARDS PORT AND STBD.
Condition: Unknown
Due 1 March 2001
Resolved 11 January 2002
Construction/Loadline
Issued 20 October 2000 Resolved
CLEAN AND REPAIR HULL AND GUNWALE STBD FWD.
Condition: Unknown
Due 1 March 2001
Resolved 11 January 2002
Lifesaving
Issued 26 April 2000 Resolved
PROVIDE 18 FT LINE ON LIFE FLOAT WATER LIGHT
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 26 April 2000 Resolved
PROVIDE COVERED LIGHT IN FWD COMP.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 26 April 2000 Resolved
PROVIDE DOUBLE HOSE CLAMPS ON EXHAUST COOLING SUPPLY HOSE.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 26 April 2000 Resolved
PROVIDE SAE J1942 OR EQUIVILANT HOSE ON FUEL RUN OVER 30".
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 26 April 2000 Resolved
PROVIDE TAMPER SEAL ON B-1 FIRE EXT.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 30 March 1999 Resolved
CONDUCT UNDERWAY DRELLS AND OPERATIONS TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1999
Resolved 29 April 1999
Unknown
Issued 30 March 1999 Resolved
VESSEL RESTRICTED TO 1 MILE FROM CG STATION STILL POND UNTIL WATER LEAKAGE IS RE-EVALUATED.
Condition: Unknown
Due 27 April 1999
Resolved 29 April 1999
Lifesaving
Issued 19 March 1998 Resolved
CHILD PFD STORAGE AREA NOT LABELED CORRECTLY.
Condition: Unknown
Due 23 March 1998
Resolved 25 March 1998
Lifesaving
Issued 19 March 1998 Resolved
RING BUOY MISSING RETRO TAPE.
Condition: Unknown
Due 23 March 1998
Resolved 25 March 1998
Lifesaving
Issued 19 March 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Documentation
Issued 19 March 1998 Resolved
NAVIGATION RULES OUTDATED. APPLICABLE T-REGS NOT ABOARD.
Condition: Unknown
Due 26 March 1998
Resolved 20 April 1998
Construction/Loadline
Issued 4 September 1997 Resolved
arrest and repair rot in starboard sheer plank at stem. No passengers may be carried after 12 DEC 97 until repairs have been completed.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Construction/Loadline
Issued 4 September 1997 Resolved
arrest and repair rot in first plank under sheer on starboard side in way of the 6th vertical frame forward of transom. No passengers may be carriedafter 12 DEC 97 until repair is complete.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Engineering
Issued 4 September 1997 Resolved
Make shaft in way of propeller available for inspection. No passengers maybe carried after 12 DEC 97 unitl shaft is inspected.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Construction/Loadline
Issued 4 September 1997 Resolved
arrest and repair rot in transom in way of sheer above the letter "W". No passengers may be carried after 12 DEC 97 until repairs have been completed.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Construction/Loadline
Issued 4 September 1997 Resolved
crop rot and rnew removed area of 4th bottom frame froward of transom. No passenger may be carried after 12 DEC 97 until repair has been completed.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Engineering
Issued 4 April 1997 Resolved
REPAIR ENGINE OIL LEAK AT OIL FILTER AREA.
Condition: Unknown
Due 4 May 1997
Resolved 5 May 1997
Documentation
Issued 4 April 1997 Resolved
PROVIDE PROOF OF ENROLLMENT IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 4 May 1997
Resolved 5 May 1997
Engineering
Issued 4 April 1997 Resolved
GROUND FUEL TANK TO COMMON GROUND PRIOR TO NEXT REFUEL.
Condition: Unknown
Due 4 May 1997
Resolved 5 May 1997
Engineering
Issued 4 April 1997 Resolved
REPAIR ENGINE COOLING SYSTEM LEAK.
Condition: Unknown
Due 4 May 1997
Resolved 5 May 1997
Lifesaving
Issued 4 April 1997 Resolved
REPLACE LIFE FLOAT PADDLES WITH (2) 4-FOOT PADDLES.
Condition: Unknown
Due 4 May 1997
Resolved 22 April 1997
Lifesaving
Issued 4 April 1997 Resolved
REPLACE GRAB LINE ON RING BUOY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 May 1997
Resolved 22 April 1997
Documentation
Issued 4 April 1997 Resolved
OBTAIN UPDATED FCC SAFETY CERTIFICATE._x001C_ OBTAIN UPDATED FCC OPERATORS LICENSE.
Condition: Unknown
Due 4 May 1997
Resolved 17 April 1997
Lifesaving
Issued 1 April 1996 Resolved
PROVIDE A APPROVED LIFE FLOAT, PADDLES AND WEAK LINK WITH PAINTER PRIOR TO OPERATING GREATER THAN ONE MILE FROM SHORE.
Condition: Unknown
Due 18 July 1996
Resolved 30 July 1996
Documentation
Issued 9 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Lifesaving
Issued 9 March 1993 Resolved
BUOYANT APPARATUS MUST HAVE MINOR REPAIR MADE TO SMALL CRACK PRIOR TO USE OF VESSEL.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Construction/Loadline
Issued 6 October 1992 Resolved
Locate and Eliminate source of incoming water in the stern area.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Engineering
Issued 24 June 1992 Resolved
FUEL TANK VENT FLAME SCREENS MISSING.
Condition: Unknown
Due 24 July 1992
Resolved 14 January 1993
Construction/Loadline
Issued 24 June 1992 Resolved
VERTICAL PLANKING LOCATED IN TRANSOM AREA BETWEEN FRAMES OUTBOARD OF FUEL TANK PORTSIDE ARE DETERIORATING AND REQUIRE REPLACING.
Condition: Unknown
Due 24 July 1992
Resolved 14 January 1993
Construction/Loadline
Issued 24 June 1992 Resolved
REPLACE 4TH LONGINTUDINAL PLANK UP FROM KEEL, BEGINNING 6" FORWARD OF FRAME#3 (COUNTING FROM BOW) EXTENDING AFT TO EXISTING BUTT JOINT.
Condition: Unknown
Due 24 July 1992
Resolved 14 January 1993
Engineering
Issued 30 March 1992 Resolved
INSTALL EMERGENCY FUEL SHUT OFF VALVES
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Engineering
Issued 30 March 1992 Resolved
REPLACE RUBBER FUEL HOSES WITH APPROVED COPPER LINE
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Documentation
Issued 30 March 1992 Resolved
PROVIDE PROOF OF DOCUMENTATION RENEWAL
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 30 March 1992 Resolved
REPAIR/REPLACE WASHBOARD AREA OF ACCESS LADDER
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 30 March 1992 Resolved
REPAIR CHIME ON PORT SIDE JOINING DECK FRAMES 4 & 5 FROM THE TRANSOM AREA
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 30 March 1992 Resolved
REPLACE DECK BEAMS 4 & 5 FROM TRANSOM DUE TO DETERIORATION
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Engineering
Issued 30 March 1992 Resolved
INSTALL FLAME SCREEN ON RAYCOR FILTER
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Engineering
Issued 28 March 1990 Resolved
MARK AFT FUEL SHUT-OFF
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Navigation
Issued 28 March 1990 Resolved
PROVIDE RULES OF THE ROAD
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Documentation
Issued 28 March 1990 Resolved
MOUNT CERTIFICATE OF INSPECTION UNDER GLASS
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Navigation
Issued 28 March 1990 Resolved
PROVIDE 1990 TIDE TABLES FOR OPERATING AREA
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Navigation
Issued 28 March 1990 Resolved
PROPERLY ALIGN ANCHOR LIGHT ON HORIZONTAL PLANE OF VESSEL
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Navigation
Issued 30 March 1989 Resolved
PROVIDE PROPER RUNNING LIGHTS AND MASTHEAD LIGHTS THAT ARE UL APPROVED OR MEET ABYC STANDARD A-16
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Navigation
Issued 30 March 1989 Resolved
PROVIDE 1989 TIDE TABLES
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Lifesaving
Issued 30 March 1989 Resolved
PLACE VESSEL NAME ON LIFEFLOAT AND CAPACITY (7 PERSONS)
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Engineering
Issued 30 March 1989 Resolved
PROVIDE INDICATOR LIGHT FOR FLOAT ACTIVATED BILGE PUMP TO SHOW THAT PUMP IS OPERATING
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Engineering
Issued 30 March 1989 Resolved
RENEW FLEXIBLE PORTION OF EXHAUST WHERE CUT AFT OF ENGINE BOX
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Engineering
Issued 30 March 1989 Resolved
RENEW FLOAT ACTIVATED SWITCH FOR ONE BILGE PUMP. BOTH PUMPS SHALL BE WIRED TO CIRCUIT BREAKER PANEL OR WITH OTHER APPROPRIATE MEANS OF CIRCUIT PROTECTION
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Electrical
Issued 30 March 1989 Resolved
PROPERLY END CABLE FROM BATTERY CHARGER IN JUNCTION BOS OR REMOVE WIRE FROMCHARGE
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Unknown
Issued 23 July 1987 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
RENEW ENGINE EXHAUST LINE WHERE LEAKING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
RENEW OR REFASTEN LEAKING BUTT BLOCKS ON STBD SIDE. ONE BUTT BLOCK IS BENEATH TILLER ARM & JUST FORWARD OF FUEL TANK. SECOND BUTT BLOCK IS ON STBD SIDE OF KEEL AND APPROXIMATELY 2' AFT OF SHAFT LOG.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
ELIMINATE LEAKAGE AROUND KEEL IN WAY OF STANCHAIN SUPPORTING AFT DECK. PROVIDE ADDITIONAL CAULKING AND/OR FASTENERS OR CARRIAGE BOLTS AS NECESSARY
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
PROVIDE EXHAUST VENT LINE WHICH IS RIGID AND FIRE PROOF.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
RENEW MAIN PROPULSION SHAFT CUTLASS BEARING PRIOR TO 1OCT87.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
PROVIDE ENGINE COMPARTMENT EXHAUST FAN/ENGINE START INTERLOCK (46CFR 182. 15-45.)
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
RENEW COPPER TUBING FUEL LINE FROM FUEL TANK TO SHUT-OFF VALVE. ENSURE IT IS PROPERLY SUPPORTED.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
SAFELY RE-ROUTE OR TRIM ENGINE COMPARTMENT EXHAUST FAN WIRING AWAY FROM BILGES AND EXHAUST.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
VESSEL IS LIMITED TO NO MORE THAN 16 ADULTS AMONG PASSENGERS AND CREW.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
INSTALL PROPER CAP ON UNUSED HULL PENETRATION.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
CROP AND REPLACE FILLER BLOCK AT AFT END OF SHAFT LOG.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
REMOVE OLD DIESEL FUEL RETURN LINE. PROPERLY CAP OLD FITTING IN TANK TOP TO WHICH OLD DIESEL FUEL RETURN LINE IS CONNECTED.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
ELIMINATE SHORT (3") LENGTH OF NON-APPROVED FLEXIBLE FUEL HOSE ADJACENT TO SHUT-OFF COCK IN STERN. MAKE PROPER CONNECTION BY FLARING EXISTING COPPER TUBING INTO COMPRESSION FITTING.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 23 July 1987 Resolved
REPLACE UNAPPROVED FLEXIBLE FUEL HOSE WITH CG APPROVED FLEXIBLE FUEL HOSE OR COPPER TUBING.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.