MAURY USCG vessel records Sign in
← All vessels

MARITIME SUZANNE

MARITIME SUZANNE is a 2002 tank ship. The Coast Guard has recorded 26 inspections since 2002, most recently in December 2017, along with 4 deficiencies and 5 operational controls.

Records from 2002 to 2017. Most recent: inspection, 28 December 2017.

Built
2002
Last inspected
28 December 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9221023 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
596651
Flag
HONG KONG
—
Maury page id
psix-596651

Inspections, by type

…with no type recorded8
Years with a record 12 calendar years (2002–2017)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29211 - Regulatory (Subpart C or D), Gross Ton
11658 - Regulatory (Subpart C or D), Net Ton
29211 - Convention (Subpart B), Gross Ton
11658 - Convention (Subpart B), Net Ton
56069 - Displacement, Ton
44363 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

28 December 2017 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6324897
18 October 2016 Ballast Water Examination · Deficiency Check · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6020228
10 September 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5720081
17 August 2015 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5220248
26 July 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5196248
26 October 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5011054
20 October 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5008579
9 October 2014 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5002515
15 July 2011 Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 4082588
7 September 2010 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3844242
28 March 2008 ISPS II Exam · MARPOL Annex I Examination · COC-CHEM Annual · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3172792
7 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3074661
5 October 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3073617
3 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3071940
5 March 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2880637
1 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2865614
27 January 2007 ISPS II Exam · COC-TVE Renew · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2862403
19 September 2005 COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2496484
20 May 2005 In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2366228
17 May 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2360488
3 September 2004 COC-CHEM Renew
Type not classified · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2184494
26 August 2004 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2177075
20 January 2004 Certificate of Compliance · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1989561
27 March 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1763693
26 March 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1764306
27 September 2002 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1681736

Deficiency record · 4

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 18 October 2016 Resolved
1930-tank washing equipment-THE EQUIPMENT AND OPERATIONS OF SHIPS CERTIFIED TO CARRY NLS IN BULK IDENTIFIED IN CHAP 17 OF THE IBC CODE SHALL BE IN COMPLIANCE WITH THE IBC CODE AND BE SURVEYED AND CERTIFIED AS PROVIDED FOR THAT CODE. THE TANK WASHING WATER SUPPULY LINE FOR TANK 3S HAS A SOFT PATCH FOR A TEMP REPAIR AND INDENTATION FROM PREVIOUS DAMAGE. -MARPOL ANNEX II/11 -40c
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 October 2016
Resolved 21 October 2016
Resolution: Pipe section replaced and tested; TEST SAT.
Construction/Loadline › Structures › Door
Issued 26 October 2014 Resolved
Code: 1270 Cite: ICLL(1966) II/12(1) Action Taken: 40ac All access openings in bulkheads at ends of enclosed superstructures shall be weathertight when closed. Both the port and starboard weathertight doors on the 2nd Poop Deck were found to not be weathertight.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2015
Resolution: Deficiency was resolved to the satisfaction of the attending Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 October 2014 Resolved
Code: 1299 Cite: ICLL(1966) II/25(3) Action Taken: 40ac Guard rails fitted on superstructure and freeboard deck shall have at least three courses. Chains fitted between two fixed stanchions and/or bulwarks are acceptable in lieu of guard rails. Above the dehumidifier room on the port side, no chains are provided in lieu of guard rails. Deteriorated rails were found in way of PV breaker.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2015
Resolution: Deficiency was resolved to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Structures › Ventilators
Issued 26 October 2014 Resolved
Code: 0510 Cite: 74SOLAS(2001) II-2/3.3 Action Taken: 40ac In combination carriers all cargo spaces and any enclosed spaces adjacent to cargo spaces shall be capable of mechanically ventilated. The mechanical ventilation for the sample locker room on the starboard side of the cargo deck was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2015
Resolution: Deficiency was resolved to the satisfaction of the attending Coast Guard Marine Inspector.

Ownership record