MAURY USCG vessel records
← All vessels

SEAPORT ELITE II

Built
2002
Last inspected
30 January 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN2834
597123
Flag
UNITED STATES
Maury page id
psix-597123

Documentation record

Registered dimensions (L × B × D)107.3 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)107.3 ft × 24.0 ft × 6.0 ft
ITC tonnagegross 279 / net 88
BuilderMID CITY STEEL FABRICATING · LACROSSE, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it279 - Convention (Subpart B), Gross Ton
79 - Regulatory (Subpart C or D), Gross Ton
88 - Convention (Subpart B), Net Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

30 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8303870
9 December 2025 Vessel Attendance · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8268592
8 January 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8037530
30 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7854182
12 December 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7830603
8 December 2022 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7592043
13 October 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7576505
21 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7379994
21 December 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7361833
13 October 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7331974
29 December 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7117389
13 October 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7076026
7 February 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6904633
30 January 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6895630
16 January 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6890689
9 January 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6885812
1 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6851111
9 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6831119
17 January 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6611547
23 October 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6566296
10 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6536813
21 February 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358607
9 January 2018 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6331434
11 December 2017 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6322532
10 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6284631
9 January 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066768
18 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6024523
6 June 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5898816
19 January 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5799603
13 January 2016 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5796770

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2025 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Battery charging did not have an ammeter installed. Install ammeter to the satisfaction of the attending marine inspector. 46 CFR 183.350(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2025
Resolved 22 January 2025
Resolution: Received objective evidance, see attached photos.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2025 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Wire connections for the sewage, potable water, and gray water tank level indicators were not enclosed. Install enclosures for the wire connections to the satisfaction of the attending marine inspector. 46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2025
Resolved 22 January 2025
Resolution: Received objective evidance, see attached photos. Conducted a def check 28JAN2025 to confirm proper installation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2023 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. At the time of inspection, the gasket around the hatch to the main engine room was found to be wasted and torn, such that CO2 vapor emitted from the vessel's fixed firefighting system would not be contained in the event of that system's deployment. 46 CFR 177.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2023
Resolved 14 December 2023
Resolution: Received objective evidance (photo) from operator correcting 835 issue.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 December 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Upper deck signage was found on forward seating area, not at either stair entranceways.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 21 December 2022
Resolution: Operator sent pics of two new max capacity signs posted on both stairways to top deck. Pics uploaded into MISLE.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 8 December 2022 Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. Placard of instructions, precautions, and warnings missing. Instructions found IAW 33CFR159.57.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 19 December 2022
Resolution: Operator sent pictures of acceptable sewage system instructions and placard. Pics added to corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 October 2022 Resolved
Each vessel constructed of a material other than wood and certificated to operate on a lakes, bays, and sounds route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. The vessel’s IBAs were removed to allow for annual servicing. Vessel is limited to a route of no more than one mile from land until primary lifesaving is serviced and reinstalled onboard the vessel.
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 8 December 2022
Resolution: IBAs were re-installed back on board
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 November 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 10 October 2017 Resolved
THE VESSEL'S 50-PERSON AND 30-PERSON INFLATABLE BUOYANT APPARATUS HAVE BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL'S OPERATION IS LIMITED TO LAKES, BAYS, AND SOUNDS NOT MORE THAN ONE NAUTICAL MILE FROM SHORE UNTIL THE IBAs HAVE BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 1 November 2017
Resolution: Inspected vessel's IBA's, no deficencies noted.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 18 October 2016 Resolved
THE VESSEL'S 50-PERSON AND 30-PERSON IBAs HAVE BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL IS LIMITED TO OPERATION WITHIN ONE NAUTICAL MILE FROM SHORE ONLY UNTIL THE IBAs HAVE BEEN REINSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 28 October 2016
Resolution: Received photos of proper reinstallation of both IBAs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.