SEAPORT ELITE II

SEAPORT ELITE II is a 2002 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 2002, most recently in January 2026, along with 29 deficiencies and 1 casualty investigation in 2019.

Records from 2002 to 2026. Most recent: inspection, 30 January 2026.

Built
2002
Last inspected
30 January 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN2834
597123
Flag
UNITED STATES
367521170
Maury page id
psix-597123

Inspections, by type

…with no type recorded2
Years with a record 21 calendar years (2002–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)107.3 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)107.3 ft × 24.0 ft × 6.0 ft
ITC tonnagegross 279 / net 88
BuilderMID CITY STEEL FABRICATING · LACROSSE, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it279 - Convention (Subpart B), Gross Ton
79 - Regulatory (Subpart C or D), Gross Ton
88 - Convention (Subpart B), Net Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2834MMSI 367521170 · active · compulsorily equipped · granted 2 July 2022, expires 2 July 2032
WDG2974MMSI 367521170 · expired · compulsorily equipped · granted 13 March 2012, cancelled 14 May 2022
WDB2989MMSI 366882140 · expired · compulsorily equipped · granted 15 February 2003, cancelled 20 April 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

30 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8303870
9 December 2025 Vessel Attendance · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8268592
8 January 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8037530
30 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7854182
12 December 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7830603
8 December 2022 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7592043
13 October 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7576505
21 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7379994
21 December 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7361833
13 October 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7331974
29 December 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7117389
13 October 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7076026
7 February 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6904633
30 January 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6895630
16 January 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6890689
9 January 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6885812
1 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6851111
9 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6831119
17 January 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6611547
23 October 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6566296
10 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6536813
21 February 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358607
9 January 2018 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6331434
11 December 2017 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6322532
10 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6284631
9 January 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066768
18 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6024523
6 June 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5898816
19 January 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5799603
13 January 2016 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5796770
29 October 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5753250
16 October 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5006373
24 March 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4821975
18 January 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4240801
25 February 2008 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3153069
13 February 2008 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3195350
11 May 2007 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2944521
24 October 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2807269
26 May 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2659698
3 February 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2578700
24 May 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2366991
25 January 2005 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2280401
14 December 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2267829
21 May 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2073790
3 February 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1999822
21 February 2003 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1749726
13 January 2003 Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1730801
13 December 2002 Damage Survey · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1718737
9 December 2002 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1725952
8 July 2002 Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1716381

Deficiency record · 29

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2025 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Battery charging did not have an ammeter installed. Install ammeter to the satisfaction of the attending marine inspector. 46 CFR 183.350(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2025
Resolved 22 January 2025
Resolution: Received objective evidance, see attached photos.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2025 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Wire connections for the sewage, potable water, and gray water tank level indicators were not enclosed. Install enclosures for the wire connections to the satisfaction of the attending marine inspector. 46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2025
Resolved 22 January 2025
Resolution: Received objective evidance, see attached photos. Conducted a def check 28JAN2025 to confirm proper installation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2023 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. At the time of inspection, the gasket around the hatch to the main engine room was found to be wasted and torn, such that CO2 vapor emitted from the vessel's fixed firefighting system would not be contained in the event of that system's deployment. 46 CFR 177.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2023
Resolved 14 December 2023
Resolution: Received objective evidance (photo) from operator correcting 835 issue.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 December 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Upper deck signage was found on forward seating area, not at either stair entranceways.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 21 December 2022
Resolution: Operator sent pics of two new max capacity signs posted on both stairways to top deck. Pics uploaded into MISLE.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 8 December 2022 Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. Placard of instructions, precautions, and warnings missing. Instructions found IAW 33CFR159.57.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 19 December 2022
Resolution: Operator sent pictures of acceptable sewage system instructions and placard. Pics added to corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 October 2022 Resolved
Each vessel constructed of a material other than wood and certificated to operate on a lakes, bays, and sounds route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. The vessel’s IBAs were removed to allow for annual servicing. Vessel is limited to a route of no more than one mile from land until primary lifesaving is serviced and reinstalled onboard the vessel.
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 8 December 2022
Resolution: IBAs were re-installed back on board
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 November 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 10 October 2017 Resolved
THE VESSEL'S 50-PERSON AND 30-PERSON INFLATABLE BUOYANT APPARATUS HAVE BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL'S OPERATION IS LIMITED TO LAKES, BAYS, AND SOUNDS NOT MORE THAN ONE NAUTICAL MILE FROM SHORE UNTIL THE IBAs HAVE BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 1 November 2017
Resolution: Inspected vessel's IBA's, no deficencies noted.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 18 October 2016 Resolved
THE VESSEL'S 50-PERSON AND 30-PERSON IBAs HAVE BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL IS LIMITED TO OPERATION WITHIN ONE NAUTICAL MILE FROM SHORE ONLY UNTIL THE IBAs HAVE BEEN REINSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 28 October 2016
Resolution: Received photos of proper reinstallation of both IBAs.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 29 October 2015 Resolved
The vessel's inflatable buoyant apparatus have been removed for annual servicing. The vessel's route is limited to not more than one mile from shore until the primary lifesaving equipment has been reinstalled to the satisfaction of an attending marine inspector.
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 6 November 2015
Resolution: Received IBA servicing certificates.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 21 October 2014 Resolved
Vessel representative informed Sector Boston that all IBA's onboard vessel will be removed for servicing on 10/21/2014 and returned NLT 11/04/2014. Vessel is restricted to one nautical mile from shore until IBA's are returned from servicing and approved by Marine Inspector.
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 24 October 2014
Resolution: IBA''s have been serviced and have been placed back onboard vessel.
Electrical › Electric Supply System (service) › Battery Charger
Issued 24 March 2014 Resolved
Direct current supply failed. Batter and battery charger in pilot house is inoperable. Bilge alarms and emergency lighting disabled due to D/C failure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2014
Resolved 25 March 2014
Resolution: Installed new compatible battery charger and battery for 2nd deck 12 volt system.
Construction/Loadline › Hull › Bottom Plating
Issued 25 January 2005 Resolved
Provide repair proposal for area in bow thruster tunnel. Steel wasted in various locations in excess of 50%. Include sketch and details of materials to be used.
Action required: 705 - Other - as specified
Resolved 4 February 2005
Construction/Loadline › Structures › Superstructure
Issued 21 May 2004 Resolved
Broken glass. Port side window near gang way.
Condition: Damaged By Earlier Event
Due 18 June 2004
Resolved 3 August 2004
Engineering › Bilge Water Management System
Issued 21 February 2003 Resolved
PROVIDE POSITIVE SHUTOFF VALVES AT HULL PENETRATIONS FOR TWO ENGINE ROOM ELECTRIC SUBMERSIBLE BILGE PUMPS PRIOR TO CARRYING PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2003
Resolution: SHUTOFF VALVES WERE PLACED AT THE HULL PENETRATIONS FOR THE TWO ENGINE ROOM BILGE PUMPS.
Documentation › Certificates/Documents
Issued 21 February 2003 Resolved
POST STABILITY LETTER WHEN RECEIVED. LEGACY COMPONENT DESC: Stability Letter
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 23 July 2003
Operations/Management
Issued 21 February 2003 Resolved
RENEW RED CROSS CERTIFICATION FOR CPR AND FIRST AID.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 7 April 2003
Documentation › Manuals/Policy Documentation
Issued 21 February 2003 Resolved
PROVIDE CURRENT COPY OF COAST PILOT.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 26 August 2003
Documentation › Markings/Placards
Issued 21 February 2003 Resolved
MARK UPPER DECK FOR ALLOWED NUMBER OF PASSENGERS AS PER STABILITY LETTER. LEGACY COMPONENT DESC: Capacity Marking
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 3 March 2003
Resolution: UPPER DECK MARKED FOR NUMBER OF PASSENGERS ALLOWED (70).
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 February 2003 Resolved
PROVIDE 6 ADULT TYPE-I PFD'S.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 3 March 2003
Resolution: 6 ADULT TYPE-I PFD''S PURCHASED.
Documentation › Certificates/Documents
Issued 21 February 2003 Resolved
PROVIDE VALID FCC STATION LICENSE.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 23 July 2003
Electrical › Lighting (emergency)
Issued 21 February 2003 Resolved
REPLACE EMERGENCY LIGHT ON MAIN DECK, STARBOARD SIDE, FORWARD. (BURNED OUT BULB)
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 22 July 2003
Electrical › Electrical Distribution System (service)
Issued 21 February 2003 Resolved
MARK ELECTRICAL CLOSET WITH SAFETY WARNING REGARDING HIGH VOLTAGE AND PROVIDE SAFETY MAT FOR SAME. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 3 March 2003
Resolution: ELECTRICAL CLOSET MARKED WITH "DANGER HIGH VOLTAGE" STICKER. NON-CONDUCTIVE SAFETY MAT PROVIDED.
Engineering › Bilge Water Management System
Issued 21 February 2003 Resolved
LABEL BILGE MANIFOLD.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 3 March 2003
Resolution: BILGE MANIFOLD LABELED WITH NUMBERS FOR EACH COMPARTMENT. BILGE DIAGRAM ALSO LABELED.
Electrical
Issued 21 February 2003 Resolved
REPLACE PLASTIC WIRE TIES WITH METAL WIRE TIES IN ALL APPLICABLE COMPARTMENTS.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 23 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 December 2002 Resolved
Provide repair proposal
Condition: Damaged By Earlier Event
Due 13 January 2003
Resolved 14 January 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 December 2002 Resolved
Conduct seatrials to the satisfaction of the attending marine inspector upon completion of repairs.
Due 13 January 2003
Resolved 14 January 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 December 2002 Resolved
Provide surveyors damage report.
Due 13 January 2003
Resolved 14 January 2003
Documentation › Certificates/Documents
Issued 13 December 2002 Resolved
Submit copy of CG 2692 to MSO Mobile investigations department. LEGACY COMPONENT DESC: CG 2692
Due 13 January 2003
Resolved 14 January 2003

Casualty record · 1

1 November 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6851111
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.