MAURY USCG vessel records Sign in
← All vessels

MSC HONG KONG V

MSC HONG KONG V is a 2002 freight ship. The Coast Guard has recorded 39 inspections since 2002, most recently in August 2025, along with 9 deficiencies and 3 operational controls.

Records from 2002 to 2025. Most recent: inspection, 30 August 2025.

Built
2002
Last inspected
30 August 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9231810 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
597643
Flag
LIBERIA
—
Maury page id
psix-597643

Inspections, by type

…with no type recorded12
Years with a record 15 calendar years (2002–2025)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it66597 - Dead Weight, Metric Ton
86597 - Displacement, Metric Ton
53453 - Convention (Subpart B), Gross Ton
33604 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

30 August 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8220904
1 August 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8197567
29 July 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8197629
2 January 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8056766
28 December 2024 PSC B · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8051409
11 November 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7593023
5 November 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7589350
17 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7536545
15 August 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7533778
15 August 2022 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7533915
13 August 2022 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7527979
24 December 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7372205
22 December 2021 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7371411
20 December 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7370868
19 December 2021 PSC B · MARPOL Annex VI Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7366878
10 February 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7139012
17 January 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125925
9 September 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7053990
30 August 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7045699
13 September 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6265630
21 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6023773
8 December 2015 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5777414
1 October 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5725958
2 January 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4216947
20 December 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3653142
14 December 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3650277
1 December 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3642326
12 December 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3378672
12 December 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3378994
11 November 2007 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3096608
15 October 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2800973
25 November 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1954961
25 November 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1955040
24 November 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1953811
14 August 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1876014
10 March 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1755496
21 November 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1709147
13 October 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1689251
13 October 2002 Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1689279

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 December 2024 Resolved
Oil fuel lines shall be screened or otherwise suitably protected to avopid, as far as praticable, oil spray or oil leakages onto hot surfaces... 74 SOLAS (01) II-2/15.2.11 PSCO observed 03 leaking fuel injectors on MDE. (Cylinders #4 and #7).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2024
Resolution: Rcvd Flag report identifying injectors that were replaced and tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to person on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCE identified that the starboard side accommodation winch guard for the air cooling fan is damaged and exposing the fan blades. This poses a significant threat to the crew and persons onboard. 74SOLAS(01)II-1/26.1
Action required: 10 - Deficiency Rectified
Resolved 6 November 2022
Resolution: Vessel was able to replace the guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2022 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. The no.6 cylinder on the main engine is currently secured due to a cylinder head crack which caused a leak. As a result engine is not able to perform at designed output. SOLAS 2014 I/11(b)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 16 September 2022
Resolved 4 November 2022
Resolution: This deficiency has been amended from a 50ac to a 60ac because the vessel failed to meet the code 50 time frame.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 December 2021 Resolved
A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. Emergency generator was unable to start under secondarmy manual menans of starting.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2021
Resolution: Received satisfactory flag dispensation letter
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 19 December 2021 Resolved
Oil residue tank shall be provided and shall be of adequate capacity having regard to the type of machinery and length of voyage to receive the oil residues which cannot be dealt with otherwise in accordance with the requirements of this Annex. PSCO observed waste oil stored in a tank not on the IOPP supplement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2021
Resolution: Received satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 December 2021 Resolved
Equipment shall be maintained to conform with the provision of present regulation to prove that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port side bilge was overfilled and in alarm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2021
Resolution: Received satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 December 2021 Resolved
Fire extinguishing appliances shall be kept in good working order and be availanble for immediate use at all times. PSCO observed 03 fire stations without spanner wrenches located by OWS, staircase entering E/R and outside electric shop, also semi portable was being blocked by machinery ports forward of #2 SSDG.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 December 2021 Resolved
ship and its equipment shall constructed to conform with these provisions to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or crewq. PSCO observed oil on the floor of the rope storage area next to steering gear as well as deck plating in front of the OWS that was wasted and could not support crew.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 August 2022
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 December 2021 Resolved
Minimum fire integrity of bulkhead shall match 44.1. PSCO observed cracks in the boundary of the purifier room by aft door.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 August 2022

Ownership record