M V AMY CANDIES

M V AMY CANDIES is a 2002 offshore supply vessel. The Coast Guard has recorded 22 inspections since 2003, most recently in October 2017, along with 33 deficiencies — 1 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2006 and 2011.

Records from 2003 to 2017. Most recent: inspection, 4 October 2017.

Built
2002
Last inspected
4 October 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9257333 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBD2739
597779
Flag
UNITED STATES
366879260 (licence lapsed)
Maury page id
psix-597779

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 10 calendar years (2003–2017)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1639 - Dead Weight, Gross Ton
1129 - Convention (Subpart B), Gross Ton
338 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB2739MMSI 366879260 · cancelled · compulsorily equipped · granted 14 November 2012, cancelled 17 June 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 22

4 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281554
6 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6167897
26 January 2016 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5803702
9 February 2012 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4227229
5 December 2010 ACP Annual Oversight · MTSA/ISPS Verification · DAPI Audit · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3893981
1 March 2010 ACP Annual Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3701348
12 December 2008 Administrative Inspection · ACP Annual Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3394794
23 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276851
30 January 2008 MTSA/ISPS Verification · Administrative Inspection · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3131572
15 May 2007 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977664
10 May 2007 Administrative Inspection · MTSA/ISPS Verification · Initial Certification · ACP COI Oversight · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2967989
15 March 2007 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2889069
13 October 2006 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2799789
13 June 2006 Cargo Tank Internal · Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2578135
9 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2582255
23 January 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2578388
15 March 2005 Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2310131
16 February 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2293576
14 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2274890
5 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2060740
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997318
30 January 2003 Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1831034

Deficiency record · 33

Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 14 February 2016 No resolution recorded
Vessel does not meet requirements to carry enough liferafts on each side to accomodate 100% of persons on board in the event of the loss of one raft. Vessel currently has 1 25-person raft on each side. Correct to satisfaction of USCG Marine Inspector or Lloyds Class Surveyor. Due by next drydock.
Action required: 705 - Other - as specified
Due 8 May 2017 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 26 January 2016 Resolved
Rescue boat has not been launched and operated in the water since May 2015, and was unable to be launched during inspection due to morring arrangements. Prior to sailing conduct rescue boat drill to include launching of rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2016
Resolved 15 February 2016
Resolution: Vessel conducted rescue boat drill to include launching. Vessel provided master's statement and pictures of vessel in operation.
Engineering › Non-conventional Propulsion/Steering › Propeller (z-drive)
Issued 5 December 2010 Resolved
Prove proper operation of port propulsion (Z drive).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Resolution: Witnessed satisfactory test of all propulsion systems.
Construction/Loadline › Structures › Door
Issued 5 December 2010 Resolved
Prove proper operation of all watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Resolution: All watertight doors have been properly adjusted and work satisfactorily.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 December 2010 Resolved
Remove all oil from bilge in generator machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Resolution: All oil removed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 December 2010 Resolved
Prove proper operation of all bilge high level alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Resolution: All alarms operational.
Construction/Loadline › Structures › Door
Issued 5 December 2010 Resolved
Prove proper operation of all watertight door indicator alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Resolution: All alarms operational.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 December 2010 Resolved
Prove proper operation of audible alarm for pilothouse engineering alarm panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Resolution: Alarm buzzer working.
Lifesaving › Inflatable Liferafts › Servicing
Issued 5 December 2010 Resolved
Prove servicing of rafts at USCG approved servicing facility. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 10 February 2011
Resolution: Received certificates of testing from CG approved life raft servicing facility.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 5 December 2010 Resolved
Replace lagging on #1 generator outboard turbo charger. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Resolved 23 December 2010
Resolution: witnessed corrected by Lloyd''s surveyor
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 5 December 2010 Resolved
Prove proper operation of port z-drive position indicator in aft machinery room. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Resolved 23 December 2010
Resolution: witnessed corrected by Lloyd''s surveyor
Communications › Internal Communications System › Sound-powered Telephone
Issued 5 December 2010 Resolved
Prove proper operation of installed telephone in aft machinery room. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Resolved 23 December 2010
Resolution: witnessed corrected by Lloyd''s surveyor
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 5 December 2010 Resolved
Prove repair of lube oil leak at #1 generator outboard turbocharger oil supply line. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Resolved 23 December 2010
Resolution: witnessed corrected by Lloyd''s surveyor
Lifesaving › Lifebuoys › Approval
Issued 5 December 2010 Resolved
Replace non-USCG approved life ring buoys with approved items. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 23 February 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 December 2010 Resolved
Replace non-USCG approved life ring float lights with approved items. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 23 February 2011
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 5 December 2010 Resolved
Prior to using #1 generator, prove repairs to lube oil leak in vicinity of rear main seal. Submit deficiency to Lloyds for issuance of condition of class.
Action required: 705 - Other - as specified
Resolved 23 December 2010
Resolution: witnessed corrected by Lloyd''s surveyor
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 1 March 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 31 March 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 March 2010 Resolved
Prior to departing port perform an annual service of the engineroom fixed CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2010
Resolution: Vessel''s enginerrom fixed CO2 system was serviced byExtintec ( Lloyd''s qualified service facility)
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 1 March 2010 Resolved
The vessel in missing two of the required four line-throwing projectiles.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2010
Resolved 24 March 2010
Stability › Watertight Integrity › General
Issued 1 March 2010 Resolved
Make repairs to watertight door alarms for bow thruster room and Z dirve emergency escape hatch.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 24 March 2010
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 March 2010 Resolved
Make repairs to the Locking mechanism to the P1 and P2 electrical panels in the control room
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 24 March 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 1 March 2010 Resolved
Prove proper operation of the Stack dampers. Dampers ore corroded and will not close when tested.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 24 March 2010
Communications › Alarms/Indicators › General Alarm
Issued 1 June 2007 Resolved
Renew general alarm to sound at all levels of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 June 2007 Resolved
Renew 2 door releases
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Communications › Visual Communication › Signalling Lamp
Issued 1 June 2007 Resolved
Renew battery for signal lamp.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 1 June 2007 Resolved
Replace 3 CO2 bottles for fixed fire fighting (removed for servicing)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Lifesaving › Immersion Suits › Not on Board
Issued 1 June 2007 Resolved
Provide proper number of immersion suits on board in proper stowage locations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 23 October 2006 Resolved
Submit to the Coast Guard Marine Safety Center for review and approval revised CO2 fixed fire suppression system plans and calculations to reflect additional combined volume to adequately protect the engine room, switchboard compartment, bow thruster compartment and escape tunnel as required by MSC Letter E1-0602791dated September 22, 2006.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 21 November 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 October 2006 Resolved
Install additional Carbon Dioxide cylinders to adequately protect the combined volume of adequately protect the engine room, switchboard compartment, bow thruster compartment and escape tunnel as required by SOLAS 74(amended) II-2/5. The installation, workmanship and testing shall be accomplished to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 21 November 2006
Engineering › Generator (propulsion-electric) › Generator Excitation Circuitry
Issued 13 October 2006 Resolved
Repair port generator propulsion engine due to crankcase explosion. Once repairs are completed an operational test of engine and propulsion system shall be conducted in the presence and satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 21 November 2006
Engineering › Non-conventional Propulsion/Steering › Clutch (z-drive)
Issued 13 October 2006 Resolved
Repair and prove operation of port Z-drive motor under full power to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 21 November 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 October 2006 Resolved
Submit for review and approval to Sector Mobile, Alabama a revised Fire Control Plan.
Action required: 705 - Other - as specified
Due 20 May 2007
Resolved 22 June 2007
Electrical
Issued 30 January 2003 Resolved
Provide approved electrical plans & automation test procedure. Correct and resolve any comments describe in plan review letters.
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 21 March 2003
Resolution: Plan review rec''d comments cleared.

Casualty record · 3

23 January 2006Routine · role: Involved in a Marine Casualty · activity 2578388
6 December 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2835850
18 June 2011Routine · role: Involved in a Marine Casualty · activity 4086268
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

M/V AMY CANDIES (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.