← All vessels
GOLDEN L
GOLDEN L is a 2002 freight ship. The Coast Guard has recorded 23 inspections since 2002, most recently in October 2021, along with 7 deficiencies and 7 operational controls.
Records from 2002 to 2021. Most recent: inspection, 30 October 2021.
- Built
- 2002
- Last inspected
- 30 October 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9216468 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EMN
597938
Flag
PANAMA
—
Maury page id
psix-597938
Inspections, by type
…with no type recorded10
Years with a record
10 calendar years (2002–2021)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it73193 - Dead Weight, Metric Ton
85717 - Displacement, Metric Ton
39958 - Convention (Subpart B), Gross Ton
25899 - Convention (Subpart B), Net Ton
85717 - Displacement, Metric Ton
39958 - Convention (Subpart B), Gross Ton
25899 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
30 October 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7342336
15 October 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7333770
9 September 2021
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7308382
29 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7748477
10 August 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7274910
18 September 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6536072
17 November 2015
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5763169
8 February 2011
Ballast Water Examination · ISPS I Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3938011
7 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3938008
5 December 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3644547
27 March 2008
Spot Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3172693
26 March 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3172294
14 March 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3164754
20 October 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3083499
23 December 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2264331
21 December 2004
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2263626
19 December 2004
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2263642
18 December 2004
ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2258845
9 May 2004
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2063120
17 October 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1930494
9 October 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928068
7 October 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1686309
2 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1684959
Deficiency record · 7
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed punctures on STBD APT and engine room. In addition, puncture on #1 DEEP F.O. Tank. PSCO also observed 3 out of 4 shaft seals are damaged and are leaking water. PSCO also observed 1 out of 3 shafts are broken on the turning gear. 74SOLAS04 1/11
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 September 2018
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire0foghting systems and appliances. PSCO observed vessel failed to conduct annual inspection of fixed CO2 fire-fighting system, in regards to functionality testing all audible alarms and test fuel shut-off controls connected to fire-protection systems for proper operation IAW MSC/Circ. 1432. Last inspection conducted 30 March 2018 only included visual inspection. Last complete inspection of CO2 fire-fighting system completed on 27 March 2017. SOLAS 74(a) 2014 cons. II-2/14.2.2.1 17 a
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 September 2018
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in accordance with the ship's maintenance plan, which should include the minimum guidelines detailed in MSC/Circ. 1432. PSCO observed onboard maintenance plan fails to provide detailed elements of inspections that are to be carried out by the crew as witnessed by monthly and annually inspection criteria of fixed fire-fighting equipment. Recognized Organization to provide corrective action plan. SOLAS 74(a) 2014 cons. II-2/14.2.1.1 16 a
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 February 2011
Resolved
1799 - Other (MARPOL) - Each transfer pipe must not leak under static liquid pressure at least 1.5 times the MAWP. C/E informed the PSCO that the bunker lines were pressure tested, however air was used as a medium.
- 33 CFR 156.170
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 February 2011
Resolved
0100 - Ship's Certificates & Documents - The transfer procedures required by 33 CFR 155.720 must contain, either in the order listed in 33 CFR 155.750 or by use of a cross reference index page. Vessel could not provide transfer procedures.
- 33 CFR 155.750
Lifesaving › Lifeboat › Watertight Enclosure
Issued 5 December 2009
Resolved
The Port & Stbd Life Boats are not watertight. Water is leaking in through the access hatches. Class to attest to the watertight integrity of the Life Boats prior to departure. 74 Solas (Cons) 2001, Ch. III Reg. 31/1.1.1 Referencing LSA Code 4.6.2.2
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 October 2003
Resolved
Vessel issued Letter of Deviation for inoperable radar.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.