Records from 2002 to 2025. Most recent: inspection, 30 April 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
30 April 2025
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101577
28 April 2025
Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101574
9 May 2023
Annual Inspection · Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7680626
23 May 2022
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7455508
22 July 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7258572
29 May 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6963810
6 June 2019
Administrative Inspection · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6706885
15 June 2018
Internal Structural Exam · COI Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6459098
6 May 2018
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6407395
11 May 2017
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6143123
3 March 2017
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6098592
18 April 2016
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5857177
22 May 2014
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4840493
23 July 2012
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4388552
1 June 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4291384
19 August 2011
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4120943
21 May 2007
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2933370
23 May 2006
Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2652614
18 May 2005
Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2361621
12 July 2004
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2134618
4 May 2004
Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2059050
2 May 2003
Initial Certification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1799304
3 October 2002
Simplified Stability Test
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1686184
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. 46 CFR 182.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2025
Resolution: All fuel hoses were double clamped.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 April 2025
Resolved
Each ring life buoy on a vessel mus be approved in accordance with 160.050 subchapter Q. Repair/replace deteriorated grab line of ring life buoy. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2025
Resolution: Lifebuoy replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworth hull. Make permenant repairs to cracked welds at bow IWO first frame.
46CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Permenant repairs effected to the satisfaction of attending Marine Inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 May 2023
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passess a chemical test for dangerous drugs for that employer. Company could not provide proof of enrollment with consortium, but stated pre-employment tests had been conducted. Provide TSS enrollment certificate and a list of enrolled Captains.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2023
Resolution: Consortium enrollment verified.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 May 2023
Resolved
All boats longer than 24' are required to be titled
unless documented by the USCG. Vessel did not have a
current registration or COD. Provide proof of
registration. 33 CFR 173
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2023
Resolution: Vessel registered with the state.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023
Resolved
An adult life jacket must be provided for each person
carried onboard. Each life jacket must be approved IAW
160.002, 160.005 or 160.055. Captains wear Type III PFD
while operating, however Type I PFD is still required.
Provide one additional Type I lifejacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 25 May 2023
Resolution: Additional lifejacket provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023
Resolved
Abandon ship, man overboard, fire drills and training
shall be logged or documented for review by the CG. Vessel logs could not be provided at the time of inspection. Draft log and provide to CG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 5 June 2023
Resolution: Log started.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023
Resolved
A vessel must carry either a first-aid kit that meets 46 CFR 199.176(b)(10) or a kit with equivalent contents. Aspirin in first aid kit was missing. Provide aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 5 June 2023
Resolution: Aspirin provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard and labeled "FIRE BUCKET". Vessel's fire buckets were all less than 2.5 gallons in capacity. Provide adequate fire buckets with proper labeling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 26 May 2023
Resolution: Fire buckets provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2022
Resolved
The vessel's first aid kit was missing medication or had expired medication. Ensure first aid kit contains all required items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 July 2021
Resolved
Marine Inspector found cracks in weld iwo gunnel on starboard side near windshield and in the bow fwd where child life jackets are stored. Gouge and repair cracks to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 1 August 2021
Resolution: Received email from vessel rep with pictures stating the weld repair was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019
Resolved
Ring buoy was beyond servicable life. Replace with servicable ring bouy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2019
Resolved 14 June 2019
Resolution: Received photos of new life ring installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 April 2016
Resolved
Complete annual inspection and conduct emergency drills in the presence of the CG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 6 May 2016
Fire Fighting › Fire Bucket › Capacity
Issued 22 May 2014
Resolved
Properly install 2.5 gallon firebuckets onboard inplace of the two gallon fire bucket.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 22 May 2014
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 4 May 2004
Resolved
Missing lanyards on the 3 required fire buckets. Attach lanyards to all 3 fire buckes.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 12 July 2004
Resolution: Done
Engineering › Fuel Oil Service System
Issued 2 May 2003
Resolved
Replace fuel supply hose with a Coast Guard Approved hose. LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 4 May 2004
Stability › Unintentional Flooding
Issued 2 May 2003
Resolved
Install a securing line or string to the bilge plug. LEGACY COMPONENT DESC: Bilge Plugs
Condition: Unknown
Due 30 May 2003
Resolved 7 May 2004
Engineering › Bilge Water Management System
Issued 2 May 2003
Resolved
Clean the bilge strainer located aft bilge section. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 7 May 2004
Electrical › Electrical Distribution System (service)
Issued 2 May 2003
Resolved
Replace bilge wire found cracked & worn. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 30 May 2003
Resolved 2 May 2003
Resolution: Done
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 May 2003
Resolved
Complete the contents on the first aid kit as per Table 46 CFR 160.054-4(B). LEGACY COMPONENT DESC: Medicine Chest
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 7 May 2004