MAURY USCG vessel records Sign in
← All vessels

KELSALL

KELSALL is a 2001 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2002, most recently in April 2025, along with 20 deficiencies.

Records from 2002 to 2025. Most recent: inspection, 30 April 2025.

Built
2001
Last inspected
30 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

598570
Flag
UNITED STATES
—
Maury page id
psix-598570

Inspections, by type

Years with a record 18 calendar years (2002–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

30 April 2025 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101577
28 April 2025 Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101574
9 May 2023 Annual Inspection · Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7680626
23 May 2022 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7455508
22 July 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7258572
29 May 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6963810
6 June 2019 Administrative Inspection · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6706885
15 June 2018 Internal Structural Exam · COI Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6459098
6 May 2018 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6407395
11 May 2017 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6143123
3 March 2017 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6098592
18 April 2016 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5857177
22 May 2014 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4840493
23 July 2012 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4388552
1 June 2012 Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4291384
19 August 2011 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4120943
21 May 2007 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2933370
23 May 2006 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2652614
18 May 2005 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2361621
12 July 2004 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2134618
4 May 2004 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2059050
2 May 2003 Initial Certification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1799304
3 October 2002 Simplified Stability Test
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1686184

Deficiency record · 20

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. 46 CFR 182.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2025
Resolution: All fuel hoses were double clamped.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 April 2025 Resolved
Each ring life buoy on a vessel mus be approved in accordance with 160.050 subchapter Q. Repair/replace deteriorated grab line of ring life buoy. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2025
Resolution: Lifebuoy replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworth hull. Make permenant repairs to cracked welds at bow IWO first frame. 46CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Permenant repairs effected to the satisfaction of attending Marine Inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 May 2023 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passess a chemical test for dangerous drugs for that employer. Company could not provide proof of enrollment with consortium, but stated pre-employment tests had been conducted. Provide TSS enrollment certificate and a list of enrolled Captains.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2023
Resolution: Consortium enrollment verified.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 May 2023 Resolved
All boats longer than 24' are required to be titled unless documented by the USCG. Vessel did not have a current registration or COD. Provide proof of registration. 33 CFR 173
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2023
Resolution: Vessel registered with the state.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023 Resolved
An adult life jacket must be provided for each person carried onboard. Each life jacket must be approved IAW 160.002, 160.005 or 160.055. Captains wear Type III PFD while operating, however Type I PFD is still required. Provide one additional Type I lifejacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 25 May 2023
Resolution: Additional lifejacket provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023 Resolved
Abandon ship, man overboard, fire drills and training shall be logged or documented for review by the CG. Vessel logs could not be provided at the time of inspection. Draft log and provide to CG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 5 June 2023
Resolution: Log started.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023 Resolved
A vessel must carry either a first-aid kit that meets 46 CFR 199.176(b)(10) or a kit with equivalent contents. Aspirin in first aid kit was missing. Provide aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 5 June 2023
Resolution: Aspirin provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard and labeled "FIRE BUCKET". Vessel's fire buckets were all less than 2.5 gallons in capacity. Provide adequate fire buckets with proper labeling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 26 May 2023
Resolution: Fire buckets provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2022 Resolved
The vessel's first aid kit was missing medication or had expired medication. Ensure first aid kit contains all required items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 July 2021 Resolved
Marine Inspector found cracks in weld iwo gunnel on starboard side near windshield and in the bow fwd where child life jackets are stored. Gouge and repair cracks to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 1 August 2021
Resolution: Received email from vessel rep with pictures stating the weld repair was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019 Resolved
Ring buoy was beyond servicable life. Replace with servicable ring bouy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2019
Resolved 14 June 2019
Resolution: Received photos of new life ring installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 April 2016 Resolved
Complete annual inspection and conduct emergency drills in the presence of the CG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 6 May 2016
Fire Fighting › Fire Bucket › Capacity
Issued 22 May 2014 Resolved
Properly install 2.5 gallon firebuckets onboard inplace of the two gallon fire bucket.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 22 May 2014
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 4 May 2004 Resolved
Missing lanyards on the 3 required fire buckets. Attach lanyards to all 3 fire buckes.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 12 July 2004
Resolution: Done
Engineering › Fuel Oil Service System
Issued 2 May 2003 Resolved
Replace fuel supply hose with a Coast Guard Approved hose. LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 4 May 2004
Stability › Unintentional Flooding
Issued 2 May 2003 Resolved
Install a securing line or string to the bilge plug. LEGACY COMPONENT DESC: Bilge Plugs
Condition: Unknown
Due 30 May 2003
Resolved 7 May 2004
Engineering › Bilge Water Management System
Issued 2 May 2003 Resolved
Clean the bilge strainer located aft bilge section. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 7 May 2004
Electrical › Electrical Distribution System (service)
Issued 2 May 2003 Resolved
Replace bilge wire found cracked & worn. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 30 May 2003
Resolved 2 May 2003
Resolution: Done
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 May 2003 Resolved
Complete the contents on the first aid kit as per Table 46 CFR 160.054-4(B). LEGACY COMPONENT DESC: Medicine Chest
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 7 May 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.