MAURY USCG vessel records
← All vessels

USNS SACAGAWEA

USNS SACAGAWEA is a 2007 public vessel, unclassified. The Coast Guard has recorded 29 inspections since 2016, most recently in March 2026, along with 23 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 26 March 2026.

Built
2007
Last inspected
26 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 March 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9271420
598795
Flag
UNITED STATES
Maury page id
psix-598795

Documentation record

Tonnage as PSIX records it43758 - Convention (Subpart B), Gross Ton
13127 - Convention (Subpart B), Net Ton
18973 - Dead Weight, Ton
41000 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

26 March 2026 Administrative Inspection · Vessel Attendance · Periodic Inspection · Deficiency Check · ACP Periodic Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8332209
27 November 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8277254
25 April 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8119890
19 March 2025 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8090845
8 November 2024 In-Service Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8032324
4 April 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7890004
10 January 2024 ACP Drydock Oversight · ACP COI Oversight · COI Inspection · Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7848641
20 June 2023 Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7719449
25 April 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7685709
28 December 2022 Damage Survey · Examination of Repairs
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7613636
27 December 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7613616
13 May 2022 ACP Annual Oversight · Annual Inspection · Administrative Inspection · ISM Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7449689
22 December 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7376289
23 September 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7318526
2 August 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7318533
26 April 2021 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7186758
15 February 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7140870
17 November 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7096600
11 October 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7091956
10 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6951146
7 October 2019 Deficiency Check · ACP COI Oversight · Administrative Inspection · In-Service Inspection · Examination of Repairs · Re-Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6911386
25 June 2019 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6724685
19 March 2019 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6644972
14 February 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6354807
11 May 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6146217
1 November 2016 Administrative Inspection · Re-Inspection · ACP COI Oversight · Construction Oversight · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6037833
27 September 2016 Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6010827
15 September 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6001698
9 February 2016 ACP Annual Oversight
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5804069

Deficiency record · 23

07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 5 April 2026 Resolved
Personal equipment shall consist of the following; a axe with a handle provided with high-voltage insulation for each of the required fireman’s outfits shall be provided. (6 Total) Attending MI’s were unable to verify the presence of these personal fire axes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 30 April 2026
Resolution: Vessel has ordered 1 per locker = 3 of a smaller axe that can be carried on your hip on FFE. Uploaded order form and cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 April 2026 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. Adequate tools and spares shall be provided to enable the equipment to be maintained. Vessel currently has L4 identified parts that are below the required quantities that shall be maintained for critical spares onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 7 June 2026
Resolution: ABS issued finding for replenishing L4 parts with extension granted to 30, Sep 2026.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2026 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Paint locker compartment had combustible trash cans storing oil rags. Replace trash cans with ones made of non-combustible materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 30 April 2026
Resolution: Vessel replaced with metal self closing lids.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 5 April 2026 Resolved
For ships constructed on or after 1 July 2014, a minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried on board. Those two-way portable radiotelephone apparatus shall be of an explosion-proof type or intrinsically safe. Ships constructed before 1 July 2014 shall comply with the requirements of this paragraph not later than the first survey after 1 July 2018. During the fire drill attending MI’s noted that the fire lockers had designated radio charging locations, however radios were missing and not being utilized by the fire teams. Each required SOLAS fireman’s outfit shall be equipped with with an approved radio, and these radios shall be designated for fire locker / fire team use to ensure availability during any emergency onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 12 April 2026
Resolution: Ship has 2 each of XG-75 Yellow UHF radios for each locker. Vessel will continue to use designated radio chargers for control access and use during drills.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 April 2026 Resolved
In cargo ships, all linings, ceilings, draught stops and their associated grounds shall be of non-combustible materials in the following spaces: in corridors and stairway enclosures serving accommodation and service spaces and control stations for ships where methods IIC or IIIC are specified as referred to in regulation 9.2.3.1. Structural fire protection insulation above the galley oven was removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 12 April 2026
Resolution: Vessel replaced missing SFP insulation above the oven.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 5 April 2026 Resolved
Test techniques must not simulate monitored system conditions by mis-adjustment, artificial signals, improper wiring, tampering, or revision of the system unless the test would damage equipment or endanger personnel. Crew did not have testing equipment for flame detectors IAW PSTP requiring ultraviolet light source be applied. Acquire ultraviolet light source testing equipment for flame detectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 30 April 2026
Resolution: Vessel ordered UV light source etsting equipment iaw PSTPs. Testing will continue to be conducted by crea, class, and USCG during VR/yard/annuals.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 5 April 2026 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. FRP grating installed along lifeboat egress route on port and starboard embarkation decks for lifeboats #1-4. Provide evidence installed FRP gratings conform to ASTM F3059-14 standard IAW USCG CG-ENG Policy Letter 01-18.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2026
Resolved 9 April 2026
Resolution: Received spec sheet and work list item of installed FRP grating which meets ASTM F3059-14.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 April 2026 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. However, holdback arrangements fitted with remote release devices of the fail-safe type may be utilized. Over 40 various self closing doors in class A/B boundaries had hold back arrangements or tie backs installed by the crew. Crew removed hold back ties and MIs brought to Master attention for further training and awareness.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2026
Resolution: Crew removed hold back ties and MIs brought to Master attention for further training and awareness.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 25 May 2022 Resolved
Maintenance and inspections of life-saving appliances shall be carried out. Noted the following outstanding lifeboat maintenance items: 1. Replacement of SOLAS retro-reflective tape on all lifeboat tops 2. Reseal of deck/hull connection due to failing seams & erosion on lifeboats #2 and #4. Satisfactory maintenance to be carried out for lifeboats. 74 SOLAS (2014) III/20.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: Verified corrective actions via ABS surveyor attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2022 Resolved
No less than two lifebuoys shall be provided with self-activating smoke signals and be capable of quick release from navigation bridge. Lifebuoy not rated for bridge quick release installed on port side navigation bridge wing. Satisfactory lifebuoy with self-activating smoke signal shall be installed on port bridge wing. 74 SOLAS (2014) III/7.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 21 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 May 2022 Resolved
Ventilators shall be provided with weather-tight closing appliances of steel or equivalent material. Noted following ventilators not weather-tight: 1. Starboard bridge wing Inlet (AC910) 01-60.5-5 missing gasket 2. Emergency supply ventilator 07-61.5-2 (Port bridge wing missing gasket) Ventilators shall be provided with weather-tight closing appliances & proper gaskets. CITE - ICLL (1988) Reg. 19(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: New gaskets installed, verified via ABS surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 25 May 2022 Resolved
All life-saving appliances shall be in working order & ready for immediate use. Lifeboat & Rescue Boat medical kits discovered to be expired (Aspirin Feb 2022). Noted in authorized annual servicing report in April 2022. Satisfactory medical kits to be provided onboard survival craft. 74 SOLAS (2014) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: New Aspirin provided and new med kits confirmed on order by company, verified via ABS surveyor.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2022 Resolved
Condition of ship shall be maintained to remain fit to proceed to sea without danger. Noted following damage to watertight/fire doors onboard: 1. Wasted door frame MJD 04-70-5 to passage 04-58-01 (Starboard Lifeboat aft vestibule) 2. Wasted watertight door WTD 01-57-5 3. Bent stairtower door frame MJD 01-67-2 (bottom door frame aft stairtower preventing full closure) Satisfactory repairs to doors shall be made. 74 SOLAS (2020)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: Corrective actions verified via ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2022 Resolved
Electrical installations shall be such to maintain auxiliary services for ship during normal operation and under various emergency conditions. Discovered electrical ground on #4 fire sprinkler pump motor controls(120V AC B-phase)- via emergency switchboard. Satisfactory troubleshooting and repairs to eliminate ground shall be conducted. 74 SOLAS (2004)II-1/40.1.1 & 40.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 May 2022 Resolved
Fire protection & fire-fighting systems shall be maintained ready for use. Discovered broken pull box glass on Cargo Pump room FM200 remote cylinder controls by entrance to space. Satisfactory repairs shall be made to cylinder pull box for FM200 system. 74 SOLAS (2014) II-2/14.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: New glass installed over pull box, verified via ABS surveyor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 May 2022 Resolved
Each non-metallic hose must be usable for oil or hazardous material service. Wasted cargo transfer hose (SN D17495) discovered onboard. Cargo hose to be removed from service & discontinued from use. 33 CFR 154.500(c)
Action required: 705 - Other - as specified
Resolved 20 June 2022
Resolution: Hose confirmed to be removed from onboard
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 10 May 2020 Resolved
All ship 500 gross tonnage and upwards shall have a gyro-compass. #2 gyro-compass failed due to inoperable AC/DC power supply. Replace power supply with In-kind parts and provide proof of proper operations.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: It has been determined that the AC to DC power supply for the @ 2 Gyro is what failed. A replacement power supply has been replaced and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 March 2019 Resolved
Reconnect remote operating handle for Lube Oil tank in EDG room and Brine Overboard Valve in Aux Machinery Space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 March 2019 Resolved
Repair damaged MCT located port side of the shaft.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 March 2019 Resolved
Repair/Replace missing SFP insulation covering adjacent to Fire Station 101 (5-58-1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 March 2019 Resolved
Provide proper material to MCT along aft bulkhead of forklift storage room to meet "A" Class boundary, black cable is not tight fitting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019 Resolved
Provide proper metal tie downs/supports for electrical cables, locations to include: Overhead of air castle, stbd forward of flight deck and forward passageway near ammo office.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 March 2019 Resolved
Repair or renew passageway door on 01 level aft of forklift stowage compartment, bottom is warping from kicking.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.