← All vessels
DAY OFF
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named DAY OFF
DAY OFF is a 2002 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 2002, most recently in June 2026, along with 107 deficiencies, 2 operational controls and 2 casualty investigations between 2008 and 2017.
Records from 2002 to 2026. Most recent: inspection, 16 June 2026.
- Built
- 2002
- Last inspected
- 16 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 107 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2008–2017
Identity
1134444
WDJ8528
599421
Flag
UNITED STATES
368017340
Maury page id
psix-599421
Inspections, by type
…with no type recorded2
Years with a record
22 calendar years (2002–2026)
The 43 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ8528MMSI 368017340 · active · compulsorily equipped · granted 22 December 2017, expires 22 December 2027
WDE2041MMSI 367319550 · expired · compulsorily equipped · granted 24 October 2007, cancelled 26 May 2018
WDB2967MMSI 366881890 · cancelled · voluntarily equipped · granted 14 February 2003, cancelled 31 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 43
16 June 2026
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8401283
25 June 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8167483
15 May 2025
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8136370
3 March 2025
Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8088827
23 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7918156
23 July 2023
Examination of Repairs · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7749933
28 February 2023
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7640004
7 November 2022
Administrative Inspection · Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7584467
10 September 2021
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7309365
9 September 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7322489
11 June 2021
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7224736
22 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7180568
11 January 2021
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7122895
26 October 2020
Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7084493
18 October 2019
COI Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6837066
13 September 2019
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6809705
1 October 2018
Examination of Repairs · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6552688
13 September 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6538726
18 December 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6325806
12 October 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6286085
18 April 2017
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6127669
3 January 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6088079
1 November 2016
Hull Examination · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6032992
10 June 2016
COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5903272
10 September 2015
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5721881
2 July 2012
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4364579
17 July 2011
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4072790
30 November 2010
Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3896593
8 December 2009
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3648567
23 December 2008
Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3391706
6 April 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3182094
26 February 2008
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3153618
19 November 2007
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3100788
19 October 2007
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3083127
12 September 2006
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2776126
22 March 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2607487
7 December 2005
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2550064
1 December 2004
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2251748
26 October 2004
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2237711
5 October 2004
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2213724
16 January 2004
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1986334
7 November 2002
Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1714195
17 October 2002
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1691171
Deficiency record · 107
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valves. The fire pump through hull sea valve was found unable to close the ingress of water.46 CFR 115.802(2)/17C.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2026
Resolved
On a ferry vessel of not more than 65 feet in length carrying not more than 49 passengers, the fire pump must be capable of projecting a hose stream from the highest hydrant, through the hose and nozzle a distance of 25 feet. Vessel is allowed to operate as a ferry vessel. Fire pump pressure relief valve was actuating with minimal pressure upon operations of the pump.46 CFR 181.300 (c) Code 17C.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 June 2026
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port side ventilation cover was missing means to close the damper. 46 CFR 182.465 (h) Code 17C.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 June 2026
Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be only weathertight. Collision bulkhead and steering compartment hatch covers were found leaking inside the spaces. 46 CFR 179.360 (a)/ COde 17C.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 June 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 June 2026
Resolved
Each EPIRB, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required shall be logged or otherwise documented. EPIRB was not tested for two months before the exam and not properly logged as required by toe code of regulations. 46 CFR 185.728(a) & (c)/ 16C.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 June 2026
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. FCC Radio Emergency Broadcasting placard was deteriorated and unreadable. 46 CFR 184.506 / 16C.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Electrical connection strip located in the void 2 forward bulkhead was found lose and one cable dead ended, including all electrical connections with oxide that shall be cleaned. 46 CFR 183.200 (a)/ 16C.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 June 2026
Resolved
Vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Steering hydraulic piston ram was found leaking through its seals. Replace hydraulic steering ram, or service to replace seals, and provide evidence of servicing to USCG Marine Inspector. 46 CFR 182.610 (a)(1) / 16C.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 June 2026
Resolved
A vessel must carry nautical chart and Current Tables. Vessel was missing above-mentioned publications. 46 CFR 184.420/ 16C.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2026
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets. 05 child size life jackets were found color faded. Replace all color faded child-size life jackets. 46 CFR 180.71 (b)/ 16C.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2026
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. The abandon ship drills are not being conducted nor logged, and the man over board drills are not being logged according with the above-mentioned requirements. 46 CFR 185.520 (a)&(f)/ code 16C.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 June 2026
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information.(1) Date of the training; and(2) General description of the training topics. A crew training log is not being implemented or completed, and was not available for USCG inspection on board. 46 CFR 185.420/ 16C.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 June 2026
Resolved
Watertight hatches must be marked on both sides in clearly legible letters at least 1 inch high: “WATERTIGHT HATCH—KEEP CLOSED”. Forward collision compartment and aft steering compartment watertight hatches are not marked as required above. 46 CFR 185.610/ 16C.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2026
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. No evidence of the above-mentioned required training was provided during the exam. Evidence of mandated training shall be provided to the satisfaction of the USCG. 46 CFR 16.401(b). 16C.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2025
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Unused electrical panel found in bathroom area and dead end wires found in bathroom area and in water tank space. Repair to the satisfaction of the attending Marine Inspector.
46 CFR 183.200(b)
16(c)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2025
Resolved
All hand portable fire extinguishers shall have permanently attaches thereto a metallic name plate giving the identifying mark of the actual manufacturer. All hand portable fire extinguishers did not have the approved bracket for the extinguisher model, according to the extinguisher manufacturer. Replace to the satisfaction of the attending Marine Inspector.
46 CFR 76.50-5(d)
16(c)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 May 2025
Resolved
A marine employer shall comply with the requirements of 4.06 in subchapter A of this chapter. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel of each individual who was directed involved. 3 crew members and 2 tests were expired. Replace to the satisfaction of the attending Marine Inspector.
46 CFR 185.212
46 CFR 4.06-15(a)(1)
16(c)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. There was no marking for the stowage of child size life jackets and they were not separated from the adult life jackets. Mark and stow to the satisfaction of the attending Marine Inspector.
46 CFR 180.78(a)(5)
10(c)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 March 2025
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction. Pitting found in a weld at the base of a guardrail on the top deck near the operating station. Repair weld to the satisfaction of the attending Marine Inspector.
46 CFR 177.900(b)
16(c)
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 6 March 2025
Resolved
At each inspection for certification and every other vessel inspection, spaces may be examined to determine that they are serviceable and in a sanitary condition. Mouse droppings discovered by water tank. Contract a company to fumigate/sanitize and provide report/cert.
46 CFR 176.818
16(c)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed its drydock inspection date.
46 CFR 176.600(c)(1)
17(c)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2024
Resolved
Code 07109: A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Pre-engineer fire extingushing system failed to shut-off engines when conducting testing. 46 CFR 181.420 (a) (3).
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 May 2024
Resolved
Code 01703: The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Marine Inspector found two openings in the engine room not vapor tight so that the extinguish medium would escape, and allow air to enter into the space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2024
Resolved
Code 07199: Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Fuel shut off valves needed cables tightened as to close completely.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 May 2024
Resolved
Code 04103: All cable and wire must have stranded copper conductors with sufficient current carrying capacity for the circuit in which they are used. Cable from the stbd selector switch starter has audiopipe wire installed. Does not meet marine grade standard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2024
Resolved
Code 01305: The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Passenger count shall be available to the coast guard upon request. No passanger count recorded onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 May 2024
Resolved
Code 11109: The float-free link required by § 180.130(a)(1) must be: (1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant;
(2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag; and
(3) Secured to the painter at one end and to the vessel on the other end. The lifloat painter line was found not attached to the weak link.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2024
Resolved
Code 07199: At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Engine room junction box exposed, with dead end wires in the forward engine room from engine room and aft comparment, ground wires for rudders pulled from connectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2023
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation. Port engine serpentine belt broke and engine overheated. The following shall be completed prior to returning to service:
1. Provide causal analysis of engine casualty
2. Provide repair plan
3. Complete satisfactory sea trial in the presence of the attending USCG Marine Inspector.
46 CFR 182.100
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The painter must be of at least 100 feet in length, but not less than 3 times the distance between the deck where the life float or buoyant apparatus it serves is stowed and the lowest load waterline of the vessel; have a breaking strength of at least 1,500 pounds; be of a dark color if synthetic, or of a type certified to be resistant to deterioration from UV light; and be stowed in such a way that it runs out freely when the life float floats away from a sinking vessel. The port and starboard painters for the 02 required life floats were found deteriorated due to UV exposure and shall be renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the
the lanyard around the body of the ring life buoy. The
lanyard was found deteriorated due to UV exposure and shall be renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 28 February 2023
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. Each item of equipment carried must have equivalent mounting or storage arrangements that do not interfere with launching. Both installed containers for the lifefloat floating waterlight impedes removal of the waterlights and prevents the light from floating free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The starboard side fuel shutoff valve was not able to close securely when operated.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 February 2023
Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. Provision must be made for closing all supply and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The installed, hinged supply and exhaust ventilation covers, had no means to secure the ventilation covers open or closed, effectively impeding ventilation to the engine space.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 February 2023
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Inspector found the port side rudder post key allowed excessive play in the steering tie bar connection.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 28 February 2023
Resolved
A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan is on the ship and that each person handling garbage follows the plan. Each garbage management plan must be in writing and (1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77; (2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and (3) Designate the person who is in charge of carrying out the plan. A garbage management plan was not provided for the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 February 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. Provide an up to date copy of the applicable U.S. Coast Pilot and Coast Guard Light List.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 February 2023
Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. Fire pump was not capable of starting locally.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 February 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. A guard cover was not provided for the rotating fire pump and belt.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Inspectors found three life jackets not to be in serviceable condition, requiring replacement and one missing life jacket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2021
Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from causing fire, explosion. machinery failure, and personnel injury. It was discovered that the vessel was involved in a reportable marine casuatly where the starboard main engine was damaged and rednered inoperable.
46CFR182.100
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 September 2021
Resolved
Employment of an individual, or service in a position by an individual, without the appropiate license. 46CFR15.401
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 September 2021
Resolved
Failure o vessel on voyage and subject to inspection to be under direction and control of an individual with the appropiate Coast Guard license. 46CFR15.515(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 January 2021
Resolved
(a) The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
Drills must be conducted prior to the vessel operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel Shutoff valve for the stb side fuel tank is not operable.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 January 2021
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals and Six hand orange smoke distress signals. Vessel had 4 expired flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 January 2021
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydro static release unit for EPIRB is expired.
Vessel restricted to operating within 3NM of shore until new Hydrostatic release unit for EPIRB arrives and is installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed dead-end cables on the bridge need to be secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 January 2021
Resolved
All fuel tanks must be electrically bonded to a common ground. Stbd side fuel tank was not bonded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2020
Resolved
Replace corroded fire main piping connecting the fire pump to the fire hydrant.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 October 2019
Resolved
(2) For a life float approved under approval series 46 CFR 160.027 or other standard. Life float is not bright orange and is missing retro reflective tape. Vessel is restricted to hold 41 passengers and 3 crew members and no more than 44 total on board.
46 CFR 180.200(C).
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 September 2019
Resolved
(A) An inspection for renewal of a certificate of inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Vessel did not conduct an Annual inspection in the designated 90 day window, the vessel must complete a full 5 year COI to re-enter service. 46 CFR 176.404
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 September 2018
Resolved
A self priming, power driven fire pump must be installed on each vessel: Of not more than 19.8 meters (65 feet) in length which is a ferry vessel; Vessel's fire pump inoperable. Vessel restricted from carrying more than 49 pax and restricted from operating as ferry until proper operation of fire pump is proved.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 13 September 2018
Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if: (1) The vessel is self-propelled; (2) The vessel has a limited coastwise route; and
(3) The vessel carries more than 49 passengers.
Vessel doesn't have radar installed. Vessel restricted from carrying more than 49 pax without a radar.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 September 2018
Resolved
Incorrect MMSI # input in VHF radio. Vessel must input correct MMSI # input in VHF radio.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 September 2018
Resolved
Gauges to indicate engine jacket water discharge temperature must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Temperature gauge for stbd engine is not working and must be repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2018
Resolved
Dead ended wiring under console, in steering compartment, and compartment fwd of engineroom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2018
Resolved
Grounding wires separated from lugs in steering compartment
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 September 2018
Resolved
Vessels of less than 50 meters in length shall exhibit an all-round white light where it can best be seen while at anchor. The pole for the anchor light was damaged during Hurricane Maria. The vessel is prohibited from anchoring at night without a suitable anchor light.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 18 December 2017
Resolved
Prove proper operation of pre-engineered CO2 alarm.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 18 December 2017
Resolved
Replace 2 B-II fire extinguishers due to corrosion.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 18 December 2017
Resolved
Prove proper operation of fire pump, belt is broken.
Documentation › Certificates/Documents › FCC SSL
Issued 18 December 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › VHF Radiotelephone
Issued 18 December 2017
Resolved
Replace VHF Radio with an integral VHF-GPS ready or connect Radio to GPS
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 18 December 2017
Resolved
Install missing heat installation on engine room hatch covers
Lifesaving › Lifefloat › Platform
Issued 18 December 2017
Resolved
Life floats must have atleast 2" of separation between each other if stacked.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 18 December 2017
Resolved
Provide Masters Marine Operator Permit
Documentation › Markings/Placards › Oil Discharge Placard
Issued 18 December 2017
Resolved
Replace oil & garbage placards.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 December 2017
Resolved
Prove proper operation of all lighting fixtures
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 December 2017
Resolved
Conduct satisfactory drills
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 12 October 2017
Resolved
Provide serviceable portable fire extinguisher. Extinguisher was found to be under charged.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 12 October 2017
Resolved
Show proper function of the bilge audible and visual alarms
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 October 2017
Resolved
Show proper operation of the self-igniting light for lifebuoy.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 12 October 2017
Resolved
Show proper installation of insulation above engine room. Provide non-combustible panel on doors
Lifesaving › Lifefloat › Serviceable
Issued 10 November 2016
Resolved
Provide a service report from an authorized lifesaving servicing technician attesting to the serviceability for the two rigid life-floats, in accordance with the manufacturer's specifications and servicing recommendations.
Lifesaving › Lifefloat › Serviceable
Issued 13 June 2016
Resolved
REPLACE 25 PAX LIFEFLOAT WITH NEW APPROVED LIFESAVING APPLIANCE
Engineering › Bilge Water Management System › Pump
Issued 10 June 2016
Resolved
REPLACE SUBMERSIBLE ELECTRIC BILGE PUMP IN ENGINE SPACE WITH OPERABLE APPROVED TYPE.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 June 2016
Resolved
REPLACE WING NUTS ON BATTERY TERMINAL CONNECTOR WITH PERMANENT TYPE CONDUCTORS
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 September 2015
Resolved
Provide an employee assistance program (EAP) for all crewmembers to include education, training, and hotline telephone number for crewmember assistance.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 December 2009
Resolved
Vessel is restricted from carrying passengers for hire until valid Certificate of Documentation is onboard.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 December 2009
Resolved
Replace broken windows in passenger accommodation area.
Personnel › Training › First Aid/CPR
Issued 26 October 2004
Resolved
PROVIDE EVIDENCE OF CPR TRAINING
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 October 2004
Resolved
PROVIDE EVIDENCE OF RANDOM DRUG TESTING PROGRAM IN PLACE.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 October 2004
Resolved
PROVIDE 1 MISSING LIFEJACKET.
Construction/Loadline › Hull › Bottom Plating
Issued 5 October 2004
Resolved
Renew bottom FRP layer on five spots below both rudders. Heavy blistering observed in this area.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 5 October 2004
Resolved
Replace both cutlass bearing on vsl's shafts.
Construction/Loadline › Hull › Side Shell
Issued 5 October 2004
Resolved
Seal bolt openings on the stern of the vessel.
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 October 2004
Resolved
Seal watertight non-metallic pipe penetrating forward of rudder room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 October 2004
Resolved
Provide missing metal tight-wraps for all electrical wires on the engine room.
Documentation › Certificates/Documents
Issued 16 January 2004
Resolved
Found expired certificate of documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Operations/Management › Drug and Alcohol Testing
Issued 16 January 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Lighting (emergency)
Issued 16 January 2004
Resolved
Provide 2 missing portable lights LEGACY COMPONENT DESC: Battery Operated Lantern
Navigation › Piloting/Steering
Issued 16 January 2004
Resolved
Provide missing publications :US Coast pilot , CG light list, Tide tables, tidal current tables. LEGACY COMPONENT DESC: US Coast Pilot
Operations/Management › Drug and Alcohol Testing
Issued 7 November 2002
Resolved
Provide proof of approved random drug testing program as required by 46 CFR 16. LEGACY COMPONENT DESC: Proof of Enrollment
Documentation › Logs/Records
Issued 7 November 2002
Resolved
Conduct and log crew training as required by 46 CFR 185.420. LEGACY COMPONENT DESC: Logbook (official)
Documentation › Certificates/Documents
Issued 7 November 2002
Resolved
Provide FCC station license. LEGACY COMPONENT DESC: FCC SSL
Documentation › Certificates/Documents
Issued 7 November 2002
Resolved
Provide FFC Safety certificate. LEGACY COMPONENT DESC: FCC Safety certificate
Communications › Audible Communications › SPD (Other)
Issued 7 November 2002
Resolved
Provide battery-operated bullhorn as required by 46 CFR 184.610.
Operations/Management › Navigation Safety
Issued 7 November 2002
Resolved
Provide up to date tide and current tables, coast pilot, light list, (Reeds Almanac is an acceptable substitute.) and navigation charts onboard vessel for areas operated. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Documentation › Markings/Placards
Issued 7 November 2002
Resolved
Post emergency broadcast placard as per 46 CFR 184.506. LEGACY COMPONENT DESC: Emergency Broadcast Placard
Communications › Audible Communications › Bell
Issued 7 November 2002
Resolved
Provide bell onboard (7.8" in diameter) meeting requirements of 33 CFR 86.23.
Fire Fighting › Fire Pumps › Pressure
Issued 7 November 2002
Resolved
Prove proper operation of fixed fire pump with regards to output pressure. Should be at least 60 psi as per 46 CFR 181.300.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 November 2002
Resolved
Install positive shut-off valve at thru hull for bilge discharge from head compartment. 46 CFR 182.520.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 November 2002
Resolved
Secure middle aft bench seat to deck.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 November 2002
Resolved
Mount vents for both fuel tank outside of engine space air intakes. 46 CFR 182.450
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 November 2002
Resolved
Provide onboard the emergency instructions as required by 46 CFR 185.510.
Casualty record · 2
6 April 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3182094
3 January 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6088079
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.