Built
2002
Last inspected
16 September 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9270256 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB4859
599734
Flag
UNITED STATES
303016000
Maury page id
psix-599734

Inspections, by type

…with no type recorded3
Years with a record 11 calendar years (2003–2019)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
325 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
97 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDL2879MMSI 303016000 · active · compulsorily equipped · granted 10 October 2019, expires 10 October 2029
WDB4859MMSI 366903160 · expired · compulsorily equipped · granted 14 May 2013, cancelled 30 September 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 17

16 September 2019 Re-Inspection · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6813241
19 October 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6564525
18 August 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4955784
7 December 2011 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4204468
14 September 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4144421
30 August 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4131114
11 August 2011 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4113187
28 September 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3859071
23 July 2008 Ballast Water Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3276578
24 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3065070
17 October 2006 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2802135
9 January 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2572283
4 August 2005 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2450567
26 July 2005 Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2440211
5 August 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2156621
25 August 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1887037
23 June 2003 Internal Structural Exam · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1824819

Deficiency record · 27

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 October 2019 Resolved
Charts found to be out of date with no corrections made.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2019
Resolved 31 October 2019
Resolution: Current charts provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2019 Resolved
Missing lagging on port inboard main propulsion engine exhaust system. Vessel is required to have area covered with protective lagging.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2019
Resolved 31 October 2019
Resolution: Lagging installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 September 2019 Resolved
Vessel did not have onboard required FCC documents to include: FCC Station License, FCC Saftey Certificate, and FCC Bridge to Bridge Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2019
Resolved 31 October 2019
Resolution: FCC documents were provided, issuing source entered incorrect vessel official number wich was addressed by vessel rep in presence of marine inspector (via phone call). Corrected documents to be verrified prior to issuance of COI.
Lifesaving › Hand Flares › Storage
Issued 14 September 2011 Resolved
Mark storage location.
Due 14 October 2011
Resolved 14 September 2011
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 September 2011 Resolved
Renew stbd MDE inboard cooling hose
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2011
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 September 2011 Resolved
Renew inboard port MDE cooling hose clamps
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2011
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 September 2011 Resolved
Renew leaking stbd S/S generator keel cooling hose
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2011
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 14 September 2011 Resolved
Replace port S/S generator keel cooler isolation valve
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2011
Engineering › Bilge Water Management System › Pump
Issued 14 September 2011 Resolved
Repair excessive leaks at bilge pump.
Due 14 October 2011
Resolved 14 September 2011
Resolution: Renewed pump in kind.
Fire Fighting › Fire Main › Condition
Issued 14 September 2011 Resolved
Tighten fire pump main at union to stop leak.
Due 14 October 2011
Resolved 14 September 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 September 2011 Resolved
Replace missing outlet box in engine room.
Due 14 October 2011
Resolved 14 September 2011
Lifesaving › Lifefloat › Float Free
Issued 4 August 2005 Resolved
Spacers missing for lifefloats
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2005
Communications › Alarms/Indicators › General Alarm
Issued 4 August 2005 Resolved
General alarm does not work under emergency power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2005
Construction/Loadline › Structures › Door
Issued 4 August 2005 Resolved
Label Watertight Doors "Watertight Door, Keep Closed While Underway"
Due 4 September 2005
Resolved 16 August 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 August 2005 Resolved
Battery connections to terminals were not secured with permanent type hardware.
Due 4 September 2005
Resolved 12 August 2005
Lifesaving › Lifefloat › Float Free
Issued 26 July 2005 Resolved
Spacers missing for lifefloats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2005
Communications › Alarms/Indicators › General Alarm
Issued 26 July 2005 Resolved
General Alarm does not work under emergency power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2005
Construction/Loadline › Structures › Door
Issued 26 July 2005 Resolved
Label Watertight doors "Watertight door, Keep Closed While Underway"
Due 4 September 2005
Resolved 26 July 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 July 2005 Resolved
Battery connections to terminals were not secured with permanent type hardware.
Due 4 September 2005
Resolved 4 September 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 July 2003 Resolved
Submit to Marine Safety Center for review and approval all required structural plans, listed in the ABS Guide for High Speed Crafts Section 1/1.11.1 "Hull Plans", not reviewed by ABS for load line purposes. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 16 October 2006
Resolution: Contacted MSC and found plan review was completed in SEP 2003.
Documentation › Safety/Response Plans/Programs
Issued 25 July 2003 Resolved
Provide Coast Guard approved propulsion control drawing as required by 46 CFR 177.202(b)(3)(i) and satisfy all outstanding comments as noted in the Marine Safety Center approval letter. LEGACY COMPONENT DESC: Propulsion Control
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 25 August 2003
Resolution: Received approval letter E2-0306016 from Marine Safety Center clearing the submittal of propulsion control drawing required by 46 CFR 177.202(b)(3)(i). Cleared outstanding comments.
Stability › Incline Test
Issued 21 July 2003 Resolved
Provide an approved Stability letter as required by 46 CFR 176.306.
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Received a copy of the approved stability letter.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 July 2003 Resolved
Provide fixed fire extinguisher servicing certificate as required by 46 CFR 176.810 (b) (2). LEGACY COMPONENT DESC: Servicing Certificate
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Received a copy of the fixed fire extinguising certificate.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 July 2003 Resolved
Properly secure electrical cables in generator space and engine room as required by 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Satisfactory inspected the proper installation of all cables in the generator space and engine room.
Communications › Audible Communications
Issued 21 July 2003 Resolved
Prove proper operation of public address system as required by 46 CFR 184.610. LEGACY COMPONENT DESC: Public Address System
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Witnessed the proper operation of the public address system.
Engineering › Bilge Water Management System › Piping
Issued 21 July 2003 Resolved
Install bilge suction piping and strainer in passageway aft of E/R as per approved bilge and fire piping system drawing.
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Inspected the installation of bilge piping as per approved bilge and fire piping drawing.
Operations/Management › Drills/Instruction
Issued 21 July 2003 Resolved
Conduct Fire, Man Overboard, and Abandon Ship drills. LEGACY COMPONENT DESC: Fire, Abandon Ship, Man Overboard
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Witnessed satisfatory Fire, Man Overboard, and Abandon Ship drill.

Casualty record · 1

9 January 2006Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2572283
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GULF SPIRIT (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record