MAURY USCG vessel records Sign in
← All vessels

VEGA

VEGA is a 2002 public freight. The Coast Guard has recorded 23 inspections since 2002, most recently in December 2020, along with 10 deficiencies and 1 operational control.

Records from 2002 to 2020. Most recent: inspection, 17 December 2020.

Built
2002
Last inspected
17 December 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9217151 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
600910
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-600910

Inspections, by type

…with no type recorded6
Years with a record 13 calendar years (2002–2020)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10604 - Dead Weight, Ton
14376 - Displacement, Ton
7406 - Convention (Subpart B), Gross Ton
3859 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

17 December 2020 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7113134
16 December 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7112706
20 March 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6644245
2 November 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5751462
2 July 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4354247
29 October 2010 PII Safety Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3881019
22 October 2010 Ballast Water Examination · Joint Vessel Security Verification (Massena only) · ISPS II Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3876978
5 December 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3645136
13 March 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3163584
9 October 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3076007
1 June 2007 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2948493
30 October 2006 Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2803949
25 August 2006 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2764117
24 August 2006 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2759420
27 May 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2660323
10 April 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2620836
16 September 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2494796
26 December 2004 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2264721
23 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2263992
12 January 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1981980
2 January 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1973202
30 May 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1803086
4 November 2002 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1700519

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 March 2019 Resolved
Fire-Extinguishing appliances shall be kept in good order and be available for immediate use at all times. Fire hose storage box located at starboard side engine room store number 6.3 was blocked by storage containers not allowing for immediate use. 74SOLAS01CONS.CHII-2/Reg 21
Action required: 10 - Deficiency Rectified
Resolved 22 March 2019
Resolution: Items blocking fire box were moved and deficiency rectified.
Fire Fighting › Fire Hoses › Condition
Issued 10 April 2006 Resolved
Firehose on vessel's focsle is ruptured. Cite:SOLAS II-2/PART E, REG. 2.1.2 Provide Coast Guard office with stamped receipt for new firehose prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2006
Resolution: Recieved faxed reciept of the purchase of 2 fire hoses.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 26 December 2004 Resolved
VESSEL MISSING NOTICE TO MARINERS FOR WEEKS 37-04 THROUGH 51-04.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2004
Resolution: Recieved fax copy of reciept for notice to mariner''s
Pollution Prevention/Response › Prevention Equipment
Issued 2 January 2004 Resolved
Required oily water seperator not in working condition as required by IOPP. To be corrected prior to departure to the sarisfaction of class and report faxed to Coast Guard. Parts were unattainable. Vessel allowed to depart for next port (PATMS) and have repairs made there. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: RECEIVED CLASS REPORT SHOWING THE OILY WATER SEPARATOR HAS BEEN CLEANED AND TESTED SATISFACTORILY.
Navigation › Piloting/Steering
Issued 2 January 2004 Resolved
Rudder Angle Indicator in steering gear flat in error of 15 degrees when hard to starboard. Not in compliance with SOLAS 74 II/1.29.11. Correct to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Class report received prior to vessel departing PHIMS. Satisfactory repairs had been made.
Lifesaving › Lifeboat Equipment
Issued 2 January 2004 Resolved
Missing following gear from life boat: 4 food rations, 1 jack knife, 2 can openers 1 spare flashlight bulb, replace sea sickness pills (they are expired), survival manual, life saving signals and 1 hatchet as required by SOLAS 74 III-41.8. Rcvd receipt for all items except life saving signals. LEGACY COMPONENT DESC: Anti-seasickness Medicine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: RECEIVED FAX RECEIPT SHOWING LIFE SAVING SIGNALS HAVE BEEN ORDERED.
Pollution Prevention/Response › Prevention Equipment
Issued 4 November 2002 Resolved
OIL TRANSFER PROCEDURES NOT AVAILABLE. MUST POST OIL TRANSFER PROCEDURE IN ACCORDANCE TO 33CFR 155.720. LEGACY COMPONENT DESC: OIL TRANSFER PROCEDURES
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2002
Resolved 6 November 2002
Navigation › Piloting/Steering
Issued 4 November 2002 Resolved
RUDDER ANGLE INDICATOR DESCREPANCIES FOUND BETWEEN BRIDGE WINGS, HELM AND STEERING GEAR FLAT. LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 6 November 2002
Resolution: RESOVLVED BY CLASS
Navigation › Piloting/Steering
Issued 4 November 2002 Resolved
REPLACE MISSING CHARTS AS FOLLOWS, 12274, 12230, 12263, 12225, 12221 OR THE FORIEGN EQUIVALENTS, 2921, 2920, 2919, LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2002
Resolved 6 November 2002
Resolution: RESOLVED BY CLASS
Fire Fighting
Issued 4 November 2002 Resolved
CERTIFICATE ISSUING ATHORITY TO CORRECT FIRE CONROL PLAN TO SHOW LOCATION OF EEBD'S LEGACY COMPONENT DESC: FIRE CONTROL PLAN
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2002
Resolved 6 November 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.