Inspection history · 63
15 May 2025
Drydock Exam · MARPOL Annex I Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8136818
30 January 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8072169
13 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7879285
23 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7700785
19 September 2022
Administrative Inspection · MARPOL Annex IV Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7555285
1 April 2022
COI Inspection · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422704
7 October 2021
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7328379
14 July 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7256071
4 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7188838
7 April 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7174084
23 October 2020
Plan Review (Other than "T") · In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7088981
7 October 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7073635
29 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6984036
23 March 2020
Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6984814
11 August 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6779663
28 May 2019
Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6696160
20 May 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6688708
24 May 2018
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6408137
10 April 2017
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6114885
7 February 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084236
14 November 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6040452
28 October 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6031110
11 January 2016
MARPOL Annex I Examination · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5795366
19 May 2015
Underwater Inspection in lieu of Drydock · Administrative Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5129939
17 December 2014
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5041308
20 October 2014
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5009930
27 January 2014
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4789858
17 January 2014
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4784735
20 December 2013
Administrative Inspection · MARPOL Annex VI Survey · Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4772234
25 November 2013
In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4759804
22 August 2013
Deficiency Check · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4694208
20 August 2013
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4693378
30 July 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4670252
10 July 2013
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4650055
24 October 2012
MARPOL Annex I Examination · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4472215
13 July 2012
Drydock Extension
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4377560
9 July 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4373246
1 June 2012
Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4399462
2 December 2011
Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4206834
22 August 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3835306
8 July 2010
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3790160
26 February 2010
MARPOL Annex IV Survey · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3686109
17 September 2009
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3597177
20 August 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3571826
7 May 2009
Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3469583
20 April 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3456625
25 November 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3374860
15 November 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3098677
18 July 2007
Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3005348
17 November 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2823961
13 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2711581
9 December 2005
MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2548983
1 June 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2382476
7 January 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270798
2 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2184028
21 June 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2323754
22 March 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2031333
2 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2000947
17 December 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1956922
2 May 2003
Examination of Repairs · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1788609
11 February 2003
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1742916
28 January 2003
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1736302
8 July 2002
Initial Certification · MARPOL Annex I Examination · COI Inspection · In-Service Inspection · Cargo Tank Internal · Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1714466
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 13 May 2024
Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided. MI observed cargo pump shaft for pump 3/5 leaking oil, which was seeping through the gastight gland. Repair prior to pump 3/5 being used for cargo ops.
46CFR32.50-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Verified gas tight seal was not leaking, all sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 13 May 2024
Resolved
Weather locations, and the structures located within them, are considered hazardous locations when within the defined distances in 46 CFR 111.105-31, and must be protected accordingly. MI observed the drain line for the pressure vessel inside the generator room penetrating through the inboard side bulkhead was not vapor tight, exposing the generator room machinery to a hazardous atmosphere. Permanently repair prior to cargo operations.
46CFR31.35-1
46CFR111.105-31
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2024
Resolution: Received class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 23 June 2023
Resolved
The High-level alarm and tank overfill alarm must be identified with the legend "High-level Alarm" and "TANK OVERFILL ALARM" in black letters on a white background with letters at least 2 inches high.
Vessel did not have any sign or legend indicating either alarm from the deck.
46 CFR 39.2007(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2023
Resolved 24 July 2023
Resolution: Received photos of the newly installed sign with white background with black lettering at tank overfill alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2023
Resolved
Nameplates of corrosion-resistant material are to be provided for the generators.
The #2 generator was missing its nameplate and associated required data.
46 CFR 31.10-1(a)
ABS Rules 4-8-3.11.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2023
Resolved 24 July 2023
Resolution: Received email with photo of generator data placard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 June 2023
Resolved
Where conduit is installed, the applicable requirements of NFPA 70, Clause 9 of IEC 61892–7: 2019, or Clause 7 of IEC of 60092–502: 1999 must be followed.
The conduit outside the tool shop house was severely corroded and had cables exposed to the elements.
Vessel must make temporary repairs prior to departing the port. Vessel must submit a permanent repair proposal for the affected conduit within 30 days.
46 CFR 31.35-1
46CFR111.105-17(b)
Action required: 705 - Other - as specified
Due 23 July 2023
Resolved 24 July 2023
Resolution: Received pictures of temporary fiberglass repairs to conduit piping. Special Note added for permanent repairs in upcoming shipyard April 2024 to witness permanent repairs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 May 2018
Resolved
Found (02) cargo pump motor to be within a class I/div I location of a cargo relief valve without proper non-metallic seal for cargo pump shaft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2018
Resolved 25 May 2018
Resolution: Vesel replaced both non-metallic seals for cargo pump shaft.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 May 2018
Resolved
Found the liferings on board to have been marked with previous vessel name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 25 May 2018
Resolution: Vessel removed old name and placed new name of vessel on the liferings.
Construction/Loadline › Structures › Door
Issued 24 May 2018
Resolved
Found one of the hatches on vessel's office area to be non-watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 25 May 2018
Resolution: Vessel repaired the dogs on hatch, proved to CG the hatch seals as intended with chalk test/light test.
Electrical › Electric Generation Source (service) › Switch
Issued 20 December 2013
Resolved
Electrical outlet was replaced with a non UL approved plug.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2014
Resolved 27 January 2014
Resolution: Verified electrical outlets were replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 20 December 2013
Resolved
A semi-portable fire extinguisher was found in poor condition. Require replacement or repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 January 2014
Resolved 27 January 2014
Resolution: Verified fire extinguisher nozzle was replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 20 December 2013
Resolved
Pressure relief valves did not have calibration certificates for annual inspection as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2014
Resolved 27 January 2014
Resolution: Document provided to show pressure relief valves were tested as required.
Operations/Management › Crude Oil Washing › Use of Inert Gas Systems
Issued 25 November 2013
Resolved
Restricted from moving barge until inert gas system is operational or another means of inerting tanks is provided. 46 CFR 32.53-30
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2013
Resolved 25 November 2013
Resolution: Demonstrated inert gas system was operational.
Operations/Management › Crude Oil Washing › Use of Inert Gas Systems
Issued 25 November 2013
Resolved
Demonstrate proper operation of inert gas system in automatic mode to the satisfaction of attending marine inspector. Inert gas system may be operated in manual mode for discharging cargo in accordance with the submitted emergency IG operations plan. 46 CFR 32.53-10
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2013
Resolved 26 November 2013
Resolution: Demonstrated proper operation of IG system in automatic mode.
Deck/Cargo › Mooring/Anchoring › Swivel Link (anchor chain)
Issued 22 August 2013
Resolved
The anchor is approximately 3 - 4 inches to wide at the fluke to seat itself as designed in the anchor home. Vessel is to periodically check the anchor when in port until a replacement anchor is installed.
Action required: 705 - Other - as specified
Due 22 September 2013
Resolved 20 September 2013
Resolution: New anchor installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 October 2012
Resolved
Lagging on starboard ballast pump exhaust piping is missing. Lagging is located in an area succeptable to contact.
Condition: Improper/Lack of Maintenance
Due 15 November 2012
Resolved 26 October 2012
Resolution: Lagging renewed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 24 October 2012
Resolved
Replace stud on port side spool for VCS.
NOTE: STUD SHOULD BE REPLACED PRIOR TO ATTACHING ANY CARGO LINES TO THE VCS FLANGE. VESSEL IS PERMITTED TO LOAD CARGO OR DISCHARGE WITHOUT MAKING A CONNECTION TO THE PORT SIDE VCS FLANGE.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2012
Resolution: Received photos of replaced stud that meets the regulatory requirement.
Accommodation/Occupational Safety › Heating › Piping
Issued 2 December 2011
Resolved
Insulation no longer installed as designed. Properly install insulation on piping for two engines.
Condition: Improper/Lack of Maintenance
Due 9 December 2011
Resolved 2 December 2011
Resolution: Insulation repair noted on worklist and scheduled to be completed.
Construction/Loadline › Hull › Side Shell
Issued 4 May 2009
Resolved
Provide repair proposal for repairs to crack in aft rack hull plating. Complete repairs to the satisfaction of CG Marine Inspector. Complete prior to loading Cargo. 46 CFR 30.01-10.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2010
Resolution: Repairs were completed prior to vessel leaving port.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 July 2007
Resolved
#1 port and stbd double sided hull voids; cracked welds found.
Action required: 705 - Other - as specified
Due 15 August 2007
Resolved 20 July 2007
Resolution: Satisfactory repairs of structural stiffners witnessed by ABS.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 17 November 2006
Resolved
Permanently attach a 0.5 inch diameter - 1.0 inch long studs at the top of all vapor connection flanges.
Action required: 705 - Other - as specified
Due 17 November 2006
Resolved 17 November 2006
Resolution: Studs attached to the top of all vapor connection flanges.
Deck/Cargo › Inert Gas System
Issued 2 May 2003
Resolved
Repair/replace the Inert gas generator Oxygen Analyzer Microprocessor LEGACY COMPONENT DESC: Oxygen Analyzer Microprocessor
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2003
Resolution: Witnessed a test of system alarms and shutdowns.
Engineering
Issued 2 May 2003
Resolved
Repair leaking flange on the hydraulic main IAW the standard for good marine practice. LEGACY COMPONENT DESC: Hydraulic piping high pressure flange
Due 7 May 2003
Resolved 6 May 2003
Resolution: Inspected and witnessed test of system by [name withheld].
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 December 2002
Resolved
Submit declaration of inspection to USCG [name withheld], WI that indicates all Cargo Pumps were operated satisfactory as per designed prior to carriage of Cargo. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2003
Resolved 27 January 2003
Operations/Management › Vessel Safety Management
Issued 9 December 2002
Resolved
Remove all extraneous materials & loose gear from main deck and stbd aft battery/sewage compartment. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2003
Resolved 27 January 2003