MAURY USCG vessel records
← All vessels

550-4

Built
2002
Last inspected
15 May 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 15 May 2025
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 24 calendar years (2002–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9271092
601119
Flag
UNITED STATES
Maury page id
psix-601119

Documentation record

Registered dimensions (L × B × D)481.9 ft × 78.0 ft × 40.0 ft
Registered tonnagegross 9,810 / net 9,810
ITC dimensions (L × B × D)481.9 ft × 78.0 ft × 40.0 ft
ITC tonnagegross 11,457 / net 5,946
BuilderMANITOWOC MARINE GROUP LLC · STURGEON BAY, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9810 - Regulatory (Subpart C or D), Gross Ton
11457 - Convention (Subpart B), Gross Ton
4888 - Displacement, Gross Ton
9810 - Regulatory (Subpart C or D), Net Ton
5946 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 63 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

COASTAL RELIANCE Towing Vessel · MISLE 591158 · 20 August 2013 · activity 4693378COASTAL RELIANCE Towing Vessel · MISLE 591158 · 30 July 2013 · activity 4670252COASTAL RELIANCE Towing Vessel · MISLE 591158 · 10 July 2013 · activity 4650055COASTAL RELIANCE Towing Vessel · MISLE 591158 · 22 August 2010 · activity 3835306COASTAL RELIANCE Towing Vessel · MISLE 591158 · 22 March 2004 · activity 2031333

Inspection history · 63

15 May 2025 Drydock Exam · MARPOL Annex I Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8136818
30 January 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8072169
13 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7879285
23 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7700785
19 September 2022 Administrative Inspection · MARPOL Annex IV Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7555285
1 April 2022 COI Inspection · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422704
7 October 2021 MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7328379
14 July 2021 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7256071
4 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7188838
7 April 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7174084
23 October 2020 Plan Review (Other than "T") · In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7088981
7 October 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7073635
29 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6984036
23 March 2020 Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6984814
11 August 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6779663
28 May 2019 Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6696160
20 May 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6688708
24 May 2018 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6408137
10 April 2017 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6114885
7 February 2017 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084236
14 November 2016 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6040452
28 October 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6031110
11 January 2016 MARPOL Annex I Examination · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5795366
19 May 2015 Underwater Inspection in lieu of Drydock · Administrative Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5129939
17 December 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5041308
20 October 2014 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5009930
27 January 2014 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4789858
17 January 2014 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4784735
20 December 2013 Administrative Inspection · MARPOL Annex VI Survey · Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4772234
25 November 2013 In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4759804
22 August 2013 Deficiency Check · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4694208
20 August 2013 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4693378
30 July 2013 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4670252
10 July 2013 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4650055
24 October 2012 MARPOL Annex I Examination · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4472215
13 July 2012 Drydock Extension
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4377560
9 July 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4373246
1 June 2012 Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4399462
2 December 2011 Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4206834
22 August 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3835306
8 July 2010 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3790160
26 February 2010 MARPOL Annex IV Survey · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3686109
17 September 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3597177
20 August 2009 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3571826
7 May 2009 Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3469583
20 April 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3456625
25 November 2008 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3374860
15 November 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3098677
18 July 2007 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3005348
17 November 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2823961
13 July 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2711581
9 December 2005 MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2548983
1 June 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2382476
7 January 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270798
2 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2184028
21 June 2004 MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2323754
22 March 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2031333
2 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2000947
17 December 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1956922
2 May 2003 Examination of Repairs · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1788609
11 February 2003 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1742916
28 January 2003 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1736302
8 July 2002 Initial Certification · MARPOL Annex I Examination · COI Inspection · In-Service Inspection · Cargo Tank Internal · Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1714466

Deficiency record · 24

02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 13 May 2024 Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided. MI observed cargo pump shaft for pump 3/5 leaking oil, which was seeping through the gastight gland. Repair prior to pump 3/5 being used for cargo ops. 46CFR32.50-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Verified gas tight seal was not leaking, all sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 13 May 2024 Resolved
Weather locations, and the structures located within them, are considered hazardous locations when within the defined distances in 46 CFR 111.105-31, and must be protected accordingly. MI observed the drain line for the pressure vessel inside the generator room penetrating through the inboard side bulkhead was not vapor tight, exposing the generator room machinery to a hazardous atmosphere. Permanently repair prior to cargo operations. 46CFR31.35-1 46CFR111.105-31
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2024
Resolution: Received class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 23 June 2023 Resolved
The High-level alarm and tank overfill alarm must be identified with the legend "High-level Alarm" and "TANK OVERFILL ALARM" in black letters on a white background with letters at least 2 inches high. Vessel did not have any sign or legend indicating either alarm from the deck. 46 CFR 39.2007(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2023
Resolved 24 July 2023
Resolution: Received photos of the newly installed sign with white background with black lettering at tank overfill alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2023 Resolved
Nameplates of corrosion-resistant material are to be provided for the generators. The #2 generator was missing its nameplate and associated required data. 46 CFR 31.10-1(a) ABS Rules 4-8-3.11.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2023
Resolved 24 July 2023
Resolution: Received email with photo of generator data placard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 June 2023 Resolved
Where conduit is installed, the applicable requirements of NFPA 70, Clause 9 of IEC 61892–7: 2019, or Clause 7 of IEC of 60092–502: 1999 must be followed. The conduit outside the tool shop house was severely corroded and had cables exposed to the elements. Vessel must make temporary repairs prior to departing the port. Vessel must submit a permanent repair proposal for the affected conduit within 30 days. 46 CFR 31.35-1 46CFR111.105-17(b)
Action required: 705 - Other - as specified
Due 23 July 2023
Resolved 24 July 2023
Resolution: Received pictures of temporary fiberglass repairs to conduit piping. Special Note added for permanent repairs in upcoming shipyard April 2024 to witness permanent repairs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 May 2018 Resolved
Found (02) cargo pump motor to be within a class I/div I location of a cargo relief valve without proper non-metallic seal for cargo pump shaft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2018
Resolved 25 May 2018
Resolution: Vesel replaced both non-metallic seals for cargo pump shaft.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 May 2018 Resolved
Found the liferings on board to have been marked with previous vessel name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 25 May 2018
Resolution: Vessel removed old name and placed new name of vessel on the liferings.
Construction/Loadline › Structures › Door
Issued 24 May 2018 Resolved
Found one of the hatches on vessel's office area to be non-watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 25 May 2018
Resolution: Vessel repaired the dogs on hatch, proved to CG the hatch seals as intended with chalk test/light test.
Electrical › Electric Generation Source (service) › Switch
Issued 20 December 2013 Resolved
Electrical outlet was replaced with a non UL approved plug.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2014
Resolved 27 January 2014
Resolution: Verified electrical outlets were replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 20 December 2013 Resolved
A semi-portable fire extinguisher was found in poor condition. Require replacement or repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 January 2014
Resolved 27 January 2014
Resolution: Verified fire extinguisher nozzle was replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 20 December 2013 Resolved
Pressure relief valves did not have calibration certificates for annual inspection as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2014
Resolved 27 January 2014
Resolution: Document provided to show pressure relief valves were tested as required.
Operations/Management › Crude Oil Washing › Use of Inert Gas Systems
Issued 25 November 2013 Resolved
Restricted from moving barge until inert gas system is operational or another means of inerting tanks is provided. 46 CFR 32.53-30
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2013
Resolved 25 November 2013
Resolution: Demonstrated inert gas system was operational.
Operations/Management › Crude Oil Washing › Use of Inert Gas Systems
Issued 25 November 2013 Resolved
Demonstrate proper operation of inert gas system in automatic mode to the satisfaction of attending marine inspector. Inert gas system may be operated in manual mode for discharging cargo in accordance with the submitted emergency IG operations plan. 46 CFR 32.53-10
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2013
Resolved 26 November 2013
Resolution: Demonstrated proper operation of IG system in automatic mode.
Deck/Cargo › Mooring/Anchoring › Swivel Link (anchor chain)
Issued 22 August 2013 Resolved
The anchor is approximately 3 - 4 inches to wide at the fluke to seat itself as designed in the anchor home. Vessel is to periodically check the anchor when in port until a replacement anchor is installed.
Action required: 705 - Other - as specified
Due 22 September 2013
Resolved 20 September 2013
Resolution: New anchor installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 October 2012 Resolved
Lagging on starboard ballast pump exhaust piping is missing. Lagging is located in an area succeptable to contact.
Condition: Improper/Lack of Maintenance
Due 15 November 2012
Resolved 26 October 2012
Resolution: Lagging renewed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 24 October 2012 Resolved
Replace stud on port side spool for VCS. NOTE: STUD SHOULD BE REPLACED PRIOR TO ATTACHING ANY CARGO LINES TO THE VCS FLANGE. VESSEL IS PERMITTED TO LOAD CARGO OR DISCHARGE WITHOUT MAKING A CONNECTION TO THE PORT SIDE VCS FLANGE.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2012
Resolution: Received photos of replaced stud that meets the regulatory requirement.
Accommodation/Occupational Safety › Heating › Piping
Issued 2 December 2011 Resolved
Insulation no longer installed as designed. Properly install insulation on piping for two engines.
Condition: Improper/Lack of Maintenance
Due 9 December 2011
Resolved 2 December 2011
Resolution: Insulation repair noted on worklist and scheduled to be completed.
Construction/Loadline › Hull › Side Shell
Issued 4 May 2009 Resolved
Provide repair proposal for repairs to crack in aft rack hull plating. Complete repairs to the satisfaction of CG Marine Inspector. Complete prior to loading Cargo. 46 CFR 30.01-10.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2010
Resolution: Repairs were completed prior to vessel leaving port.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 July 2007 Resolved
#1 port and stbd double sided hull voids; cracked welds found.
Action required: 705 - Other - as specified
Due 15 August 2007
Resolved 20 July 2007
Resolution: Satisfactory repairs of structural stiffners witnessed by ABS.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 17 November 2006 Resolved
Permanently attach a 0.5 inch diameter - 1.0 inch long studs at the top of all vapor connection flanges.
Action required: 705 - Other - as specified
Due 17 November 2006
Resolved 17 November 2006
Resolution: Studs attached to the top of all vapor connection flanges.
Deck/Cargo › Inert Gas System
Issued 2 May 2003 Resolved
Repair/replace the Inert gas generator Oxygen Analyzer Microprocessor LEGACY COMPONENT DESC: Oxygen Analyzer Microprocessor
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2003
Resolution: Witnessed a test of system alarms and shutdowns.
Engineering
Issued 2 May 2003 Resolved
Repair leaking flange on the hydraulic main IAW the standard for good marine practice. LEGACY COMPONENT DESC: Hydraulic piping high pressure flange
Due 7 May 2003
Resolved 6 May 2003
Resolution: Inspected and witnessed test of system by [name withheld].
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 December 2002 Resolved
Submit declaration of inspection to USCG [name withheld], WI that indicates all Cargo Pumps were operated satisfactory as per designed prior to carriage of Cargo. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2003
Resolved 27 January 2003
Operations/Management › Vessel Safety Management
Issued 9 December 2002 Resolved
Remove all extraneous materials & loose gear from main deck and stbd aft battery/sewage compartment. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2003
Resolved 27 January 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.