MAURY USCG vessel records Sign in
← All vessels

GOIN' PLACES

GOIN' PLACES is a 2002 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2002, most recently in July 2026, along with 31 deficiencies.

Records from 2002 to 2026. Most recent: inspection, 29 July 2026.

Built
2002
Last inspected
29 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

601574
Flag
UNITED STATES
367331580 (licence lapsed)
Maury page id
psix-601574

Inspections, by type

Years with a record 18 calendar years (2002–2026)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 3.0 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT FLORIDA TRADING · TAVARES, FL, UNITED STATES · built 2002
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE2919MMSI 367331580 · expired · compulsorily equipped · granted 15 January 2008, cancelled 17 March 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

29 July 2026 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8469430
17 October 2025 Plan Review "T" Boat · Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8277510
16 September 2024 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7996927
13 June 2024 Drydock Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7934132
14 June 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6714144
5 November 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6577923
26 July 2017 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6221326
21 November 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6048998
30 October 2015 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5754373
9 October 2014 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5004963
25 August 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4959933
2 February 2011 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3939462
14 January 2011 DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3925890
24 November 2010 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3897489
3 February 2010 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3674754
14 January 2009 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3400312
28 October 2008 Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3352788
19 May 2008 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3211212
18 January 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3132776
15 October 2007 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3080443
22 January 2007 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2862205
2 October 2006 Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2791591
16 November 2005 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2535660
15 February 2005 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2293033
19 January 2005 Plan Review "T" Boat
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2349367
1 December 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2252960
27 October 2004 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2229297
19 March 2004 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2027415
9 January 2004 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1980127
27 November 2002 Hull Examination · Construction Oversight · Plan Review "T" Boat · Simplified Stability Test
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1711585
1 November 2002 Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1736486

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2018 Resolved
Provide this office with a Repair Proposal to address the continued issues with both engines stalling out (i.e. Loss of Propulsion). This office understands that the vessel operator will install two new engines once his company has approved funding. Note: Vessel owner has stated that both of the new engines will be the "same in kind" as the existing engines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 16 September 2024
Resolution: The vessel's engines have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2018 Resolved
(Post installation of new engines) - Conduct satisfactory U/W Drills and Sea Trials in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 16 September 2024
Resolution: Drills and sea trials were completed during the COI Renewal.
Construction/Loadline › Hull › Hull Plating
Issued 9 October 2014 Resolved
Make repairs to center pontoon's third compartment from the aft and the forward compartment on the front pontoon to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2015
Resolved 23 February 2015
Resolution: Repairs to center and port pontoon were conducted to the satisfaction of the attending marine inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 January 2011 Resolved
RESECURE BATTERIES LOCATED IN STARBOARD COMPARTMENT.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2011
Resolution: Owner resecured the batteries in the starboard compartment.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 January 2011 Resolved
UPDATE LETTER OF ENROLLMENT IN CONSORTIUM OR PROVIDED TESTING PLAN
Due 14 February 2011
Resolved 4 November 2015
Resolution: LETTER PROVIDED FOR CONSORTIUM
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 January 2011 Resolved
PROVIDE UPDATED TIDE TABLES
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2011
Resolution: Owner updated the vessel''s tide tables.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 January 2011 Resolved
PROVIDE CHAFFING GEAR TO PROTECT STARBOARD SIDE CONTROL WIRE.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2011
Resolution: Owner provided chaffing gear to protect starboard side control wire.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 January 2011 Resolved
RENEW STARBOARD RUNNING LIGHT.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 3 February 2011
Resolution: Owner repaired stbd running lights.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 24 February 2010 Resolved
All S.S. Marine Venture, Inc. vessels are restricted from operating, unless properly crewed with crew members who have had pre-employment drug tests with negative results.
Action required: 705 - Other - as specified
Due 24 March 2010
Resolved 19 March 2010
Resolution: The O/O supplied missing documentation of company''s Drug & Alcohol program and provided proof from his consortium that all his crewmembers had pre-employment drug tests that were negative and were enrolled in the consortium''s random drug testing pool.
Communications › Alarms/Indicators › General Alarm
Issued 3 February 2010 Resolved
Demonstrate proper operation of "alarm check" function on port and stbd engines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2010
Resolved 24 February 2010
Resolution: The owner had a engine technician repair the "alarm check function"
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 February 2010 Resolved
Complete Drug and Alchol Program audit.
Action required: 705 - Other - as specified
Due 25 February 2010
Resolved 23 February 2010
Resolution: Sec Jacksonville did a DAPI audit on the SS Marine Ventures Inc. company on 23FEB10 and found the company was not in compliance. Another CG-835 was issued for the company to provide proof of pre-employment drug testing.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 January 2009 Resolved
Replenish first aid kit with missing items and provide water tight container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 4 February 2009
Resolution: First aid kit replaced with a new one with water tight container.
Engineering › Fuel Oil Service System › Valve
Issued 26 January 2009 Resolved
Fuel shut off valves are not approved for marine use replace with non cock-type valves, or cock-type with solid bottom. As per 46 CFR 182.455 (a)3.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 4 February 2009
Resolution: Fuel shut off valves were replaced with non cock-type valves.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 October 2007 Resolved
Lifesaving equipment maintenance records need to be maintained, as well as steering checks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 25 January 2008
Resolution: Records are being maintained and are on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 October 2007 Resolved
Provide all Nav. publications
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 25 January 2008
Resolution: Provided pubs
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 October 2007 Resolved
Replace life jacket placard to fit the jackets that are onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 25 January 2008
Resolution: Placard was renewed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 October 2007 Resolved
Provide a first aid kit.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2007
Resolution: New first aid kit.
Lifesaving › Lifebuoys › Serviceable
Issued 18 October 2007 Resolved
Replace the life ring due to the rotten grab line.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2007
Resolution: Buoy has been replaced.
Construction/Loadline › Hull › Hull Plating
Issued 2 October 2006 Resolved
Crop and renew a minimum of 12 inch x 12 inch end plate of the starboard pontoon.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Endcap insert full penetration weld.
Construction/Loadline › Hull › Hull Plating
Issued 2 October 2006 Resolved
Remove weldment in way of port outboard pontoon sprat rail aft bracket. Properly repair pin hole leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Fracture drill stopped; v-grooved, then welded. New spray rail with brackets fitted to original.
Construction/Loadline › Hull › Hull Plating
Issued 2 October 2006 Resolved
Remove weldment in way of starboard outboard pontoon spray rail, located approximately 12 inches forward of the nose cone weld attachment. Properly repair the 3 inch fracture.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Fracture drill stopped. V-grooved, then welded. New spray rail with brackets fitted to original.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 December 2004 Resolved
Provide an approved automatic electric float light for the ring life buoy. Until the light is properly mounted, the vessel is restricted to daylight operations only.
Condition: Placed in Improper Service
Due 5 December 2004
Resolved 1 December 2004
Construction/Loadline › Hull › Bracket
Issued 27 October 2004 Resolved
REPAIR AS ORIGINAL THE BOW HORIZONTAL FINS AND THE MOTOR POD HORIZONTAL FINS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 1 December 2004
Documentation › Certificates/Documents › Stability Letter
Issued 19 March 2004 Resolved
VESSEL MUST DEMONSTRATE COMPLIANCE WITH SIMPLIFIED SUBDIVISION.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 15 February 2005
Resolution: Sister vessel, M/V DOWNTOWN, O.N.1135861, passed a damage stability test.
Documentation › Certificates/Documents
Issued 9 January 2004 Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE VALID COD ON VESSEL. COD EXPIRED 30NOV03. NVDC HAS NO RECORD OF RENEWAL AT THIS TIME. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2004
Resolution: Received copy of COD.
Lifesaving › Visual Distress Signals (General)
Issued 1 November 2002 Resolved
PROVIDE ON BOARD TWO (2) ADDITION HAND HELD SMOKE SIGNALS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2002
Stability
Issued 1 November 2002 Resolved
PROVIDE ON BOARD THE STABILITY LETTER.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2002
Resolution: 16711/D1135117 DTD NOV. 1, 2002
Pollution Prevention/Response
Issued 1 November 2002 Resolved
PROVIDE ON BOARD THE MARPOL V POLLUTION PLACARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2002
Operations/Management › Passenger Operations
Issued 1 November 2002 Resolved
POST THE EMERGENCY BROADCAST INSTRUCTION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2002
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 November 2002 Resolved
PROVIDE THE CERTIFICATE OF DOCUMENTATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2002
Documentation › Markings/Placards › Official Number (US)
Issued 1 November 2002 Resolved
APPLY TO THE VESSEL STRUCTURE THE OFFICIAL NUMBER.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.