Records from 2002 to 2018. Most recent: operational control imposed, 23 October 2018.
Documentation record
Tonnage as PSIX records it17077 - Convention (Subpart B), Net Ton
17077 - Simplified, Net Ton
50316 - Dead Weight, Ton
58136 - Displacement, Ton
27986 - Simplified, Gross Ton
27986 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 16
23 October 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6566598
2 October 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6553278
29 September 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6549221
20 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5818497
22 July 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4081268
25 October 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3351146
9 February 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3144755
16 June 2006
ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2681727
8 June 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2675475
30 May 2006
Administrative Inspection · ISPS I Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2664681
30 May 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2665878
26 May 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2659804
2 November 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2527275
19 April 2003
Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1776495
19 November 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1707812
12 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1707160
Lifesaving › Rocket Parachute Flares › General
Issued 9 February 2008
Resolved
09FEB2008-Vessel's 12 bridge hand rocket flares are expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Resolution: Received receipt of the new pyrotechnics which will renew the expired pyro on the bridge.
Lifesaving › Hand Flares › Expired
Issued 9 February 2008
Resolved
09FEB2008-Vessel's Port and Starboard lifeboat pyrotechnics; rocket flares, hand flares, and smoke signals are expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Resolution: Received receipt of the new pyrotechnics to fulfill the required amount in each lifeboat.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 30 May 2006
Resolved
Did not submit Ballast Water Report prior entry into Jacksonville FL as per 33 CFR 151.2041 (b) (3) and IMO Res A.868 (20) I/8.1.3, correct to satifaction of Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2006
Resolution: Attended vessel and attested to proper submission on BWM report to the NBIC. Vessel was found to be in compliance.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 30 May 2006
Resolved
The ballast water management plan was a photocopies of ballast procedures and not vessel specific. 33CFR 151.2035 (a) (7) and IMO Res A.868 (20) I/7.1, to satisfaction of class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 December 2006
Resolution: Verified ballast Water Management plan was vessel specific and approved by class. Cleared deficiency.