← All vessels
GIL
GIL is a 2001 freight ship. The Coast Guard has recorded 20 inspections since 2002, most recently in August 2011, along with 20 deficiencies and 7 operational controls.
Records from 2002 to 2011. Most recent: inspection, 20 August 2011.
- Built
- 2001
- Last inspected
- 20 August 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9037288 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6YW2
602600
Flag
BAHAMAS, THE
—
Maury page id
psix-602600
Inspections, by type
…with no type recorded9
Years with a record
6 calendar years (2002–2011)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6167 - Convention (Subpart B), Gross Ton
3146 - Convention (Subpart B), Net Ton
9190 - Dead Weight, Ton
12175 - Displacement, Ton
3146 - Convention (Subpart B), Net Ton
9190 - Dead Weight, Ton
12175 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
20 August 2011
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4121598
26 July 2011
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4095086
9 July 2011
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4080078
8 July 2011
COE-Offshore
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4073786
10 February 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3939550
21 September 2006
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2783130
28 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2523892
14 September 2005
NPV Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2492163
2 September 2004
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2184032
16 September 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1905994
5 August 2003
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1867554
4 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1866305
4 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1869996
24 July 2003
MARPOL Annex I Examination · Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1854788
25 April 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1782587
24 April 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1780195
24 April 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1780201
7 February 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1741647
22 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1710269
18 November 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1706846
Deficiency record · 20
Navigation › Piloting/Steering › Gyro Compass
Issued 20 August 2011
Resolved
Vessel's gyrocompass is inoperable. Issued LOD.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 February 2011
Resolved
Multiple doors in the main verticle zone did not close fully.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 February 2011
Resolved
Both doors leading to the galley did not close fully, and the door from the galley to the passage way had the self closing devise removed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 February 2011
Resolved
Emergency generator could not be started with a secondary means.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 14 September 2005
Resolved
Class society to ensure galley service window is acceptable as an 'A' class boundry. Window doesn not seal around edges.
Documentation › Logs/Records
Issued 5 August 2003
Resolved
The Oil Record Book entries for incinerator usage are well in excess of the capacity listed on the IOPP Certificate and the manufacturer's technical manual. The master was instructed to note this item as a non-conformity with-in the vessel's SMS.
LEGACY COMPONENT DESC: Oil Record Book
Engineering › Diesel Engine (propulsion-direct drive)
Issued 5 August 2003
Resolved
The main engine mounted cooling water pump seal failed causing a power irregularity in the Mississippi River. Repair replace seal and prove proper operation of main engine to the satisfaction of class. Rectify deficiency prior to movement.
LEGACY COMPONENT DESC: Cooling water pump
Engineering › Steering Gear System
Issued 5 August 2003
Resolved
The steering gear has a two to three degree hunt in two pump operation from 25 degrees Port to 35 degrees Port. Provide technician's report rectifying this situation and prove proper operation. Rectify deficiency prior to movement.
LEGACY COMPONENT DESC: Pump
Engineering › Steering Gear System
Issued 5 August 2003
Resolved
The steering compartment has excessive hydraulic oil on deck and slippery and the wooden grates are soaked with oil. Wipe up all oil and remove replace wooden grates.
Engineering › Fuel Oil Storage/Transfer System
Issued 5 August 2003
Resolved
The fuel purifier space has excessive standing oil in the bilge and the lagging is oil soaked. Wipe up oil and replace oil soaked lagging. LEGACY COMPONENT DESC: Filter/Strainer
Lifesaving › Immersion Suits
Issued 18 November 2002
Resolved
VESSEL DOES NOT HAVE ENOUGH EMERSION SUITS FOR ALL PERSONS ASSIGNED TO RESCUE BOAT. ONE ADDITIONAL REQUIRED
Lifesaving › Embarkation Appliances/Stations
Issued 18 November 2002
Resolved
VESSEL DOES NOT HAVE PORT AND STARBOARD EMBARKATION LADDERS THAT MEET SOLAS 74. LEGACY COMPONENT DESC: Steps
Lifesaving › Lifejacket/PFD (General)
Issued 18 November 2002
Resolved
FIVE LIFEJACKET LIGHTS DO NOT OP0ERATE. PROVIDE REPLACEMENTS. LEGACY COMPONENT DESC: Lights
Lifesaving › Lifebuoys
Issued 18 November 2002
Resolved
TWO LIFEBUOY LIGHTS ARE DAMAGED, PROVIDE REPLACEMENTS. LEGACY COMPONENT DESC: Quantity
Fire Fighting › Firemans Outfit
Issued 18 November 2002
Resolved
VESSEL MUST HAVE (8) EEBD BOTTLES FILLED. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Fire Fighting › Nozzles
Issued 18 November 2002
Resolved
VESSEL MISSING (1) FIRE NOZZLE. LEGACY COMPONENT DESC: Number
Fire Fighting › Fire Hoses
Issued 18 November 2002
Resolved
VESSEL MISSING (5) FIRE BOXES LOST IN HEAVY WX. LEGACY COMPONENT DESC: Number
Lifesaving › Liferaft Equipment
Issued 18 November 2002
Resolved
VESSEL IS USING REQUIRED SAFETY LAMPS FOR OTHER PURPOSES. LEGACY COMPONENT DESC: Electric Torch
Documentation › Certificates/Documents
Issued 18 November 2002
Resolved
SAFETY EUIPMENT CERTIFICATE FORM E DOES NOT REFLECT CORRECT CARRIAGE REQUIRMENTS AS REQUIRED BY SOLAS. TO BE UPDATED OR EXEMPTION CERTIFICATE ISSUED. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Documentation › Certificates/Documents
Issued 18 November 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.