Records from 2002 to 2019. Most recent: inspection, 3 April 2019.
Inspection history · 23
3 April 2019
ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6650593
11 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6623532
25 May 2018
Ballast Water Examination · COE-Dockside · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6417689
29 October 2016
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6031616
23 July 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5950125
23 July 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5950241
7 January 2016
COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5789571
11 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5740326
11 September 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5738707
19 September 2010
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 3852845
21 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3421632
30 January 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3402926
17 March 2008
MARPOL Annex II Examination · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3164804
20 September 2006
PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2783028
14 September 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2777775
9 August 2006
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2741590
21 June 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2687413
18 June 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2683093
10 August 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2579191
28 June 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2406744
28 June 2005
ISPS III Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2406872
15 June 2004
MTSA/ISPS Verification · Certificate of Compliance
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2100697
21 November 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1708852
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 May 2018
Resolved
07106 - Fire Safety - Any fixed fire detection system shall be capable of immediate opertion at all times. Smoke detector in framo pump power distribution room is inoperable.
74 SOLAS 2001 cons.CHII-2/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 25 May 2018
Resolution: Deficiency was cleared on the spot.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 25 May 2018
Resolved
03112 - Water/Weathertight Conditions - The machinery and associated systems shall be of a design and construction adequate for the service for which they are intended. Associated piping aft of general service pump 02 has a soft patch.
74 SOLAS 2004 cons. CHII-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 27 May 2018
Resolution: Received Class Report attesting to the repair of piping system. See Class Report.
Construction/Loadline › Structures › Door
Issued 25 May 2018
Resolved
02102 - Structural Conditions - All access openings in bulkheads permanently attached to the bulkhead shall be weathertight when closed. Door to IGG blower room does not seal properly.
ILLC Annex 1 CH2/12.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 27 May 2018
Resolution: Received Class Report attesting to satisfactory functionality of weathertight door. See Class Report.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 29 October 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship in all respects will remain fit to proceed to sea. Number 5 cylinder of the main engine not functioning properly. SOLAS 74 (Con. Ed. 14) I Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2016
Resolved 29 October 2016
Resolution: Vessel replaced affected cylinder and conducted engine tests. All sat.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 21 November 2002
Resolved
Provide suitable arrangement at each cargo tank such that the condition of the tank atmosphere can be determined using portable instruments. Prior to next U.S. Port after sailing foreign.
SOLAS 74 II-2/62.17
Action required: 705 - Other - as specified
Due 21 January 2003
Resolved 15 June 2004
Resolution: The vessel had approved Items on board and fixed the Deficiency.
Documentation › Manuals/Policy Documentation
Issued 21 November 2002
Resolved
Include a provision, where it is ensured that all valves used during a cargo transfer operation are closed upon completion of transfer, in the transfer procedures. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2002
Resolved 21 November 2002
Resolution: Transfer procedures updated prior to completion of boarding.
Fire Fighting › Firemans Outfit › Quantity
Issued 21 November 2002
Resolved
Provide a fireman's outfit to bring the total number onboard to five. Prior to next U.S. Port after sailing foreign.
SOLAS 74 amd II-2/17
SOLAS 74 amd II-2/54
IBC 14.1
Action required: 705 - Other - as specified
Due 21 December 2002
Resolved 15 June 2004
Resolution: The Vessel had a total of five fireman''s outfits.