MAURY USCG vessel records
← All vessels

AQUA ADVENTURE

AQUA ADVENTURE is a 2003 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in April 2026, along with 21 deficiencies and 2 casualty investigations between 2017 and 2019.

Records from 2016 to 2026. Most recent: inspection, 15 April 2026.

Built
2003
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB3224
603804
Flag
UNITED STATES
Maury page id
psix-603804

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMAALAEA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Net Ton
44 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

15 April 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8349724
28 January 2025 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8071048
8 October 2024 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8016377
28 February 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7871682
14 February 2023 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7636217
8 December 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7605989
29 September 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571032
23 March 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7416940
23 February 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7400722
16 November 2021 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7352561
7 July 2021 Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7305902
5 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7190177
7 December 2020 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7108690
22 July 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7013570
14 May 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6953467
29 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6672890
28 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6651625
7 March 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6642190
29 November 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6592412
6 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6366522
27 February 2018 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6365047
18 April 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132527
16 March 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6106298
15 December 2016 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6088452
28 April 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886137

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 21 Marlin Type 1 life jackets installed on vessel (Model 320RT for Adults and Model 321RT for Child size) have a malfunctioning spring-loaded tab on the snap hook of the safety strap. The spring-loaded tabs fail to spring back,(return to closed position) after depressing to secure snap hook in place. Renewal required for all affected Lot #'s. Vessel has 33 serviceable adult life jackets on board, therefore passenger count shall be reduced to 31 passengers + 02 required crew, until affected life jackets are replaced with serviceable Type 1 life jackets. 46 CFR 176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2026
Resolved 27 May 2026
Resolution: New life jackets received and installed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 January 2025 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test and make available for inspection all items in the ship's outfit, navigation lights and equipment, which are required to be carried by the regulations in this subchapter, as necessary to determine that they are fit for the service intended. Both Mast head light and anchor light inoperable during inspection. Vessel restricted to daylight hours only and shall not be remain in an anchored position until deficiency is rectified. 46 CFR 176.816
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Mast light and anchor light renewed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2025 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of(50 pounds per foot) applied to the top rail in any direction. Multiple deck rail base plate screws located at port and starboard bow missing. Requires renewal and or installation. 46 CFR 177.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 11 February 2025
Resolution: All deck rail base plates secured properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's stbd fuel shutoff valve was not operable. 46 CFR 182.455(b)(4)
Action required: 10 - Deficiency Rectified
Resolved 28 February 2024
Resolution: Fuel shutoff operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 February 2022 Resolved
Visual indicator must be provided at the operating station to indicate when any auto bilge pump is operating. Visual indicator at operating station not working for laz auto bilge pump. Provide operational visual indicator. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 1 March 2022
Resolution: Visual indicator provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 22 March 2022
Resolution: Procedures provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2021 Resolved
The selection of crewmembers for random drug testing shall be made by a scientifically valid method, such as a random number generator that is matched with crewmembers' Social Security numbers, payroll identification numbers, or other comparable identifying numbers. Under the testing frequency and selection process used, each covered crewmember shall have an equal chance of being tested each time selections are made and an employee's chance of selection shall continue to exist throughout his or her employment. Current selection process is not a scientifically valid method. Ensure random selection process complies with the above requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 8 September 2021
Resolution: DER provided proof of scientifically random selection process.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutesof training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 8 September 2021
Resolution: DER provided proof of completion for EAP training for all required personnel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2021 Resolved
Bilge pump indicator light at helm not functioning when pump is in automatic. Make light at bilge operational for all auto bilge pumps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: New bulbs intalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2021 Resolved
Port engine would not start. Could not test Pre-engineered fixed fire fighting system. Make engine operational and test pre-engineered fixed fire fighting system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Engine operational. Pre-engineered fixed firefighting test completed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 May 2021 Resolved
Navigation publication not on vessel. Provide navigation publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 17 May 2021
Resolution: Nav pubs provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2021 Resolved
Flammable materials located in forward space. Remove all flammable materials or provide approved flame locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 15 June 2021
Resolution: Removed flammable materials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2021 Resolved
The discharge ends of fuel tank vent pipes must terminate on the hull exterior as high above the waterline as practicable and remote from any hull openings, or they must terminate in U-bends as high above the weather deck as practicable and as far as practicable from openings into any enclosed spaces. Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions. Diesel fuel vents onboard vessel vent into vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 15 June 2021
Resolution: Added vent to exterior of vessel
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 March 2019 Resolved
Compass light was extinguished. Repair in accordance with 46 CFR 184.402. Vessel limited to day light operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2019
Resolution: Light provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2019 Resolved
High pressure fuel line clamps were loose or missing on port and stbd engines. Repair/replace in accordance with 46 CFR 176.804
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 29 April 2019
Resolution: Clamps provided and installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 March 2019 Resolved
VHF DSC function was not programmed. Prove DSC capability in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 29 April 2019
Resolution: Radio programmed.
Engineering › Fuel Oil Service System › Valve
Issued 27 February 2018 Resolved
Port fuel tank emergency shut-off did not close completely. Repair in accordance with 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Due 27 March 2018
Resolved 6 March 2018
Resolution: Cable shortened, valve closes completely.
Stability › Watertight Integrity › General
Issued 27 February 2018 Resolved
Forward and aft engine room watertight bulkhead penetrations were not sealed. Make watertight in accordance with 46 CFR 179.360.
Condition: Improper Installation
Due 27 March 2018
Resolved 5 March 2018
Resolution: Penetrations sealed.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 27 February 2018 Resolved
Port engine high pressure fuel line not clamped properly. Repair in accordance with 182.200
Condition: Improper/Lack of Maintenance
Due 27 March 2018
Resolved 5 March 2018
Resolution: Clamp adjusted. Fuel line secured.
Fire Fighting › Fire Bucket › Quantity
Issued 28 April 2016 Resolved
Fire buckets need to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2016
Resolution: Fire buckets were replaced.
Engineering › Lubricating Oil Service System › Gauge
Issued 28 April 2016 Resolved
Replace oil pressure sensor.
Due 27 May 2016
Resolved 28 April 2016
Resolution: Sensor replaced.

Casualty record · 2

16 March 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6106298
7 March 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6642190
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.