Records from 2012 to 2026. Most recent: inspection, 28 May 2026.
Inspection history · 18
28 May 2026
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8377314
23 April 2026
Administrative Inspection · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8355269
9 December 2025
Deficiency Check · Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8311641
5 August 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8202919
8 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7967568
29 May 2024
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7941540
16 June 2023
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7716394
17 May 2023
COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7686787
2 August 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7517528
14 June 2022
In-Service Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7470698
10 August 2021
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7248589
12 August 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7023453
17 June 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6971201
19 August 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6770377
23 May 2018
DAPI Audit · Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6421768
15 August 2017
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6248785
18 August 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5975604
2 June 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5895302
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 April 2026
Resolved
Received report that the vessel struck a piling with its bowsprit while mooring. Make vessel, bowsprit, and rigging available for inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2025
Resolved
Identified an area of rot on the mainmast at the mast partner location spanning approx. 1/3 the circumference x 24". Submit repair proposal and complete repairs prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2025
Resolved
Identified an area of rot on the foremast masthead spanning nearly the entire circumference x 24". Submit repair proposal and complete repairs prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2025
Resolved
Received notification that the crew discovered an area of rot on the mainmast under the rubber boot at the deck partner. Make both the mainmast and foremast available for inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2025
Resolved
Conduct sea trials prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 August 2025
Resolved
The screen on the VHF radio is sun-damaged preventing the Captain from determining what channel the radio is monitoring. Replace DSC-VHF Radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2025
Resolved 21 August 2025
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 August 2025
Resolved
The globe on the compass is sun-damaged preventing the Captain from determining the vessel's heading. Replace compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2025
Resolved 21 August 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 August 2025
Resolved
The glass on the forward starboard port hole cover is no longer in place. Repair or replace the port hole cover to make weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2025
Resolved 21 August 2025
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 8 August 2024
Resolved
Vessel's pre-engineered fixed gas fire extinguishing system (Fireboy) must an audible alarm that sounds upon discharge. Provide audible alarm and test.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2020
Resolved
Install a visual indicator at the operating station to indicate when any automatic bilge pump is running.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 September 2020
Resolution: Vessel rep installed a visual indicator at the operating station to indicate when each of the automatic electronic submersible bilge pumps were operating.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2020
Resolved
Glass from daggar board found worn and allowed for waterborne insect damage to impact wooden structur of board. Remove impacted wood, replace, and restore fiberglass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 14 July 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2020
Resolved
Plates for Gooseneck fitting on both masts are cracked on opposing upper corners. Replace both plates to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 12 August 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2020
Resolved
The forked bracket attaching the gooseneck to the boom for both the forward and aft mast are cracked. Replace both brackets to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 12 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019
Resolved
Provide serviceable 24in ring buoy with vessel name and retro-reflective tape, must meet Q spec 160.050.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2019
Resolution: New ring buoy onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2019
Resolved
Connections to battery terminals must be of the permanent type. Wing nuts not considered permanent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Wing nuts removed and replaced with standard nut.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2019
Resolved
Battery connections (terminal post) must be protected from falling objects and short-circuiting or arcing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Terminal boots installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 August 2019
Resolved
Replace fuel vent screen, screen was wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Screens replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 August 2019
Resolved
Securely connect grounding wire from fuel tank fill to tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Grounding wire attached.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2019
Resolved
Provide installation dates for all rigging components listed in Appendix (1) to Enclosure (1) of NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2019
Resolution: Rig inventor provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2019
Resolved
Make available a Rigging Preventative Maintenance Program that provides a level of detail commensurate with Appendix (2) to Enclosure (1) of NVIC 02-16 (Rigging Inventory/Preventative Maintenance Inspection Template (Sample)) or propose a mutually acceptable third party to survey the rigging and provide a report with a level of detailed commensurate with either Appendix (3) or (4) to Enclosure (1) of NVIC 02-16 (Third Party Rigging Survey Samples A&B).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 September 2019
Resolution: Received vessels PMP.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2019
Resolved
Provide picture of top rigging connection point: triatic "extension/turnbuckle" to main/mizzin mast.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2019
Resolution: Picture of rigging received.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 24 May 2018
Resolved
Renew or hydrostatically test fixed pre engineered gas fire extinguishing cylinder.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 13 June 2018
Resolution: Fireboy cyclinder replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 24 May 2018
Resolved
Clearly label location for forward portable fire extinguisher.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 31 May 2018
Resolution: Label added to bulkhead
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 24 May 2018
Resolved
Renew shackle for port forestay.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 31 May 2018
Resolution: Shackle replaced
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 15 August 2017
Resolved
Vessel must maintain a complete first aid kit at all times. Provide complete first aid kit.
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 22 August 2017
Resolution: Purchased all required items to complete first aid kit.
Communications › Alarms/Indicators › Fire Alarm
Issued 15 August 2017
Resolved
Provide audible alarm for Fire Boy
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 22 August 2017
Resolution: Installed new audible/visual indicator
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 August 2017
Resolved
Renew B-II portable fire extinguishers, provide service tag for A-II
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 22 August 2017
Resolution: Purchased/intalled new extinguishers
Communications › Radio Communications › VHF Radiotelephone
Issued 15 August 2017
Resolved
Provide VHF-DSC radio programmed with vessel's MMSI and integrated GPS
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 22 August 2017
Resolution: Purchased, isntalled and programmed a GPS integrated VHF-DSC radio