Behind this panel: 4 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2017
Resolved
74 SOLAS (14)III/Reg 7: Lifejackets complying with the requirements of paragraphs 2.2.1 or 2.2.2 of the code. PSCO found lifejackets (39 total) do not have SOLAS approval stamps or match with expired certificate. (17abc)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2017
Resolution: Vessel procured new SOLAS approved life jackets and lights. Verified by Class and Coast Guard.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 May 2017
Resolved
74 SOLAS (01)I/11: Condition of ship shall not be changed after survey. Engine room smoke detectors taped together taped to hold together due to vibration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2017
Resolution: Procured new smoked detectors installed and tested. Verified by Class and Coast Guard.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 31 May 2017
Resolved
74 SOLAS (01)II-2/Reg 44.1: In addition to complying with specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1. Bulkheads in fire control room and emergency generator room were heavily deteriated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2017
Resolution: Vessel procured new A-60 rated fire protection covering and installed.Veriified by Class and Coast Guard.
Stability › Unintentional Flooding › General
Issued 31 May 2017
Resolved
74 SOLAS (14)I-11: Conditon of ship shall not be changed after survey. Ballast pump is leaking straight stream of water from packling gland.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2017
Resolution: Vessel procured new packing and installed on Starboard forward ballast pump. Test ran and verified that weeping for cooling is no more than a drip. Verified by Class and Coast Guard.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 31 May 2017
Resolved
33 CFR 155.720: Vessel owner/operator shall provide transfer procedures meeting requirements of 33 CFR 155 and 156. Vessel did not provide any transfer procedures for bunkering operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2017
Resolution: Vessel developed conplete transfer procedures and updated line diagram in accordance to US Regulations. Reviewed and verified by Coast Guard.
Lifesaving › Launching Appliances › Davit
Issued 8 December 2016
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the operational test of the lifeboat/rescue boat's launching appliance, the davit was not operational. 74 SOLAS (14 cons.) III/20 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2016
Resolved 9 December 2016
Resolution: Received class report attesting to the proper repair of the lifeboat/rescue boat davit.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 December 2016
Resolved
All ships 3000 gross tonnage and upwards shall have an x-band and s-band radar. Veesel's x-band radar was not operational. 74 SOLAS (14 cons.) V/19.2.7.1 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2016
Resolved 9 December 2016
Resolution: Received class report attesting to the proper repair of the X-band radar.
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 December 2016
Resolved
A means of communication shall be provided between the navigation bridge and the steering gear compartment. During the testing of emergency steering, PSCO observed no operable form of communication from the bridge to the steering gear. 74 SOLAS (04 cons.) II-1/29.10 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2016
Resolved 9 December 2016
Resolution: Received class report attesting to the proper working order of steering gear room communications.
Construction/Loadline › Structures › Door
Issued 8 December 2016
Resolved
The escape ladder from the machinery space shall provide continous fire shelter. The door and frame to the escape trunk on the engine control roon deck are in poor condition. The door is rusted-out at the bottom, not properly self-closing and the surrounding frame and insulation are sufficentlty degraded, reducing its fire protection. 74 SOLAS (01 cons) II-2/ 45.3.1 (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 December 2016
Resolved 31 May 2017
Resolution: Verified repairs on scene during vessel exam.
Construction/Loadline › Structures › Door
Issued 8 December 2016
Resolved
Stairwells shall be surrounded by at least A-O class divisions and be protected by self-closing doors at all levels. The two doors to the stairwells on the boat deck did not properly self-closing due to broken handles. 74 SOLAS (01 cons) II-2/46.1 (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 December 2016
Resolved 31 May 2017
Resolution: Verified repairs during vessel exam.
Engineering › Freshwater Generation System › Pump
Issued 8 December 2016
Resolved
The condition of the ship and its equipment shall be maintained and remain fit to proceed to sea without danger to the ship or persons on board. PSCOs observed the reverse osmosis water pump had a severe water leak. 74 SOLAS (14 cons) I/11a (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 December 2016
Resolved 31 May 2017
Resolution: Verified repairs during vessel exam.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 December 2016
Resolved
Every ship shall carry an appropriate portable atmospere testing instrument or instruments. Suitable means shall be provided for the calibration of such equipment. Vessel was unable to provide calibration equipment for the portable gas meter. 74 SOLAS (14 cons) XI-1/7 (40ac)
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 December 2016
Resolved 31 May 2017
Resolution: Verified correction during vessel exam. Crew had calibration contract and equipment calibration records.