Records from 2002 to 2023. Most recent: inspection, 7 April 2023.
Documentation record
Registered dimensions (L × B × D)170.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 599 / net 599
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC & C MARINE AND REPAIR INC · BELLE CHASE, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it599 - Simplified, Gross Ton
599 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
7 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7664506
7 February 2022
Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7391692
8 December 2021
Internal Structural Exam · Damage Survey · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7364751
8 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7173598
21 January 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7128366
14 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7077271
25 January 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6934681
4 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6742257
7 May 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6679114
11 April 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6389407
15 March 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6372201
9 June 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6213745
9 August 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6013132
21 June 2016
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914623
7 March 2016
Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5830886
10 March 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5105131
18 August 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4958627
12 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4814790
12 April 2012
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4285058
24 January 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4230563
2 March 2010
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3688778
7 April 2009
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3448220
26 February 2008
COI Inspection · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3153837
2 May 2007
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2920976
9 May 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2645032
4 May 2005
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2348959
11 March 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2022664
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976290
7 November 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1943902
27 October 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1936905
9 December 2002
Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1716615
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 December 2021
Resolved
Each tank vessel with a cargo capacity of 1,000 or more cubic meters, loading oil or oil residue as cargo, must have one overfill device that is permanently installed on each cargo tank and meets the requirements of this section. Port aft overfill device has a mechanical malfunction.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2022
Resolution: Alarms were repaired and tested satisfactorily.
Documentation › Markings/Placards › Warning Signs
Issued 21 June 2016
Resolved
Warning sign is missing the word "WARNING" and needs to be added as specified in the CFR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 9 August 2016
Resolution: "WARNING" was stenciled onto the existing sign; picture proof provided.
Engineering › Fuel Oil Service System › Piping
Issued 21 June 2016
Resolved
Prime mover return fuel line is worn and has cracks along its entire length, which needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 9 August 2016
Resolution: Replaced worn fuel line with a new, approved fuel line; provided picture proof.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 10 March 2015
Resolved
No benzene sign on board
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2015
Resolution: New benzene sign placed on board
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 26 February 2008
Resolved
Sight glass on #2 P tank cracked and needs replacement.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2008
Resolved 3 April 2008
Resolution: Item replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 11 March 2004
Resolved
VSL TRANSFER HOSE AND PIPING WERE IMPROPERLY MARKED.
Condition: Improper/Lack of Maintenance
Due 11 March 2004
Resolved 11 March 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 March 2004
Resolved
VSL DRAFT MARKINGS WERE NOT MARKED PROPERLY.
Condition: Improper/Lack of Maintenance
Due 11 March 2004
Resolved 11 March 2004
Deck/Cargo › Vapor Control Systems
Issued 11 March 2004
Resolved
VAPOR RECOVERY GAUGE ON PIPING NEEDS CALIBRATION TO REFLECT TRUE PRESSURE. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Improper/Lack of Maintenance
Due 11 March 2004
Resolved 11 March 2004
Deck/Cargo › Vapor Control Systems
Issued 9 December 2002
Resolved
Vessel still awaiting MSC approval letter for vapor recovery system and cargo authority letter.
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 27 October 2003
Resolution: 27 Oct 2003 - Received necessary paperwork from the Marine Safety Center to approve the Vapor Recovery System. MSC also issued the required list of cargoes. The approval letter serial # is C2-0306625.