15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 March 2023
Resolved
15109 - Safety Management Systems (ISM) - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations, and with any additional requirements which may be established by the company. Due to the objective evidence detailed in the below deficiencies, the vessel is not in substantial compliance with the relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. An external audit conducted by the Flag or RO is required to determine whether the ship is operating in accordance with the ISM code. Provide a copy of the complete audit report to USCG prior to departure from port.
74 SOLAS (20) IX / 3.1
ISM A / 10.1
17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2023
Resolution: ISM audit conducted by Class. 2 NC due by July
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 March 2023
Resolved
01315 - Certificates & Documentation - Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the ORB part I, so that all entries in the book appropriate to that operation are completed. PSCO discovered the following issues (a-b):
a) ORB entries for the offload of oily waste did not match offload receipts provided by the vessel.
b) ORB is missing oily bilge soundings.
MARPOL ANNEX I / 17.4
17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2023
Resolution: Class surveyor and tech provided training to crew. ISM audit reflected isues found.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 11 March 2023
Resolved
01117 - Certificates & Documentation - An IOPP certificate shall be issued; after an initial or renewal survey in accordance with the provisions of regulation 6 of this annex. PSCO discovered inaccuracies regarding sludge tanks found on the vessel. ORB lists weekly soundings of 5 sludge tanks (PORT/STBD sludge tanks, PORT/STBD waste oil tank, oil recovery tank) when only 2 tanks are listed on the IOPP.
MARPOL ANNEX I / 7.1
17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2023
Resolution: IOPP updated to reflect missing tanks.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 11 March 2023
Resolved
99102 - Other - After any survey of the ship under Regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment covered by the survey, without the sanction of the administration. PSCO discovered the following issues (a-g):
(a)Observed rest/recreation room adjacent to engine room which was a CO2 protected space.
(b)Observed 4 sea chests on the vessel, only 1 was operational.
(c) Currently 4 bilge/fire pumps on the vessel, crew informed PSCO that STBD FWD pump is primary and being used. Tested fire pump STBD AFT and observed a leak of 5 gallons per minute when pump is not running.
(d) When testing PORT Emergency Generator, observed major exhaust leak.
(e) Observed multiple portable filtration systems on lube oil/hydraulic system, system not on approved piping diagram.
60 SOLAS / chapter 1 / reg. 11
17 ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2023
Resolution: All concerns address see class report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2023
Resolved
09209 - Working and Living Conditions - ...All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. PSCO observed standing water in light receptacle in Engine CO2 room.
60 SOLAS / chapter 2 / reg. 27 (a) (i) (i)
17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2023
Resolution: Electrical fixed.