BLUE EVERTON is a 2002 freight ship. The Coast Guard has recorded 3 inspections since 2019, most recently in September 2022, along with 2 deficiencies.
Records from 2019 to 2022. Most recent: inspection, 9 September 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19872 - Convention (Subpart B), Gross Ton 19872 - Regulatory (Subpart C or D), Gross Ton 39684 - Displacement, Metric Ton 32474 - Dead Weight, Metric Ton 11140 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
9 September 2022PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7554234
4 June 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6968156
14 February 2019ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6615639
02105
Structural Conditions
The steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration.
Both the number one and number two steering gear pumps have active leaks originating from the ram seal and the local steering unit seal. The number one steering gear pump was empty of hydraulic oil and had to be filled from the backup reservoir.
74 SOLAS(04) II-1/29.2.1
60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2019
Resolved 14 February 2019
Resolution: Recieved Class report satisfying all regulations.
01199
Certificates and Documentation
Each nonmetallic transfer hose must not be burst, bulge, leak or abnormally distort under static liquid pressure at least 1.5 times the maximum allowable working pressure. Chief Engineer was unable to provide proff of hydrostatic testing of bunkering system at 150% Maximum Allowable Working Pressure.
33 CFR 156.170
40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 June 2019
Resolved 14 February 2019
Resolution: Recieved Class report satisfying all regulations.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National