CHEMBULK KOBE

Built
2002
Last inspected
12 July 2019
Documentation
No record in the NVDC file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 July 2019
…with no type recorded13
Operational controls 1 with no removal date recorded
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9263136
604744
Flag
MARSHALL ISLANDS
Maury page id
psix-604744

Documentation record

Tonnage as PSIX records it11573 - Convention (Subpart B), Gross Ton
6084 - Convention (Subpart B), Net Ton
19996 - Dead Weight, Metric Ton
25281 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

12 July 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6747226
27 June 2019 Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6724172
27 June 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6457425
5 April 2018 COE-Dockside
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6384961
28 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6329870
17 December 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6325721
12 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6286569
27 July 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6222348
26 July 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6220181
29 June 2017 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6191170
21 June 2017 ISPS II Exam · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6183087
8 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6120056
7 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6121111
30 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6114469
24 March 2017 COE-Dockside
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6109678
2 February 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6081925
27 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6078404
12 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6020914
12 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6020947
1 August 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5959539
31 July 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5959526
30 May 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5883194
29 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5891069
29 May 2016 COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5891095
24 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5885356
27 January 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5804732
22 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5801673
20 January 2016 ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794265
16 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798570
16 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798700

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 June 2019 Resolved
All the steering gear components shall be of sound and reliable construction. PSCO observed grinding noise emitting from steering gear when traveling between 0 and 5 degrees port and starboard on both steering pumps. 74SOLAS(04)II-1/29.2.1 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew cleaned the bearing grove of the rudder carrier and refilled with lubricant. Steering test was conducted without grinding noise. Deficiency rectified to satisfaction of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed numerous power cables improperly installed in connection boxes/electrical apparatus (conductors are pulled out of housing) 74SOLAS(04)II-1/45.1.3 50a
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew opened the gland fittings and cables were properly re-inserted and tightened. Deficiency rectified to satisfaction of class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Each vessel vapor connection flange must have a permanent stud projecting outward located at the top of the flange. PSCO observed port side manifold vapor connection flange stud as threaded and not permanently affixed. 46CFR39.2001(j) 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew welded the studs into the flange. Deficiency rectified to satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 June 2019 Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. Port State Control Examiners observed six capillary tube penetrations in the bulkhead between the ballast pump room lower section and engine room loose, not maintaining fire integrity. 74SOLAS(04)II-2/9.1.3 16a
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew checked the pusher ring, packing, and plate in the bulkhead penetration gland and retightened thereafter. Fireclay was applied into the gland at pump room side to maintain fire integrity.
Lifesaving › Launching Appliances › Falls
Issued 17 December 2017 Resolved
Falls used in launchng shall be inspected periodically with special regard for areas passing through sheaves. During abandon ship drill the port side life boat was lowered to embarkation deck. The forward sheave on the forward arm is seized and did not rotate at all.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2018
Resolved 28 December 2017
Resolution: SEC HOU-GAL PSC Branch received a class report satisfying the requirement
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 July 2017 Resolved
Main and emergency switchboards shall be so arranged so the sides and rear are suitably guarded. Found approximately 6" by 18" unsealed openings on back of main switchboards and 6" x 18" unsealed openings on each side of emergency switchboard. (74 SOLAS 01 II-1/45.2) (50ac)
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 30 July 2017
Resolution: Received class report attesting that all openings have been fitted with sheet metal enclosures.
Construction/Loadline › Markings › Load Line Mark
Issued 27 July 2017 Resolved
The rings, lines, and letters shall be painted in white or yellow on a dark background. Load line renewal survey was carried out in June 2017 but the deck line is not painted a contrasting color to the hull. (ILLC Annex I/8) (50ac)
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 30 July 2017
Resolution: Received class report attesting to the fact that deck line has been painted a contrasting color to the hull.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 27 July 2017 Resolved
Cargo tanks must not be filled higher than the level at which an overfill alarm complying with 46 CFR 39.2007 or 39.2009(a)(2) is set. Vessel's overfill alarm for #6P cargo tank is continuously alarming. The set point for the vessel's overfill alarm is at an ullage of 1.234m and the current ullage of the tank is 1.07m. (46 CFR 39.3001(e)(2)) (40c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2017
Resolved 12 October 2017
Resolution: PSC HOU recieved DNV-GL Class report satisfying requirements.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 July 2017 Resolved
PSCOs found eight cargo tank butterworth hatches with broken or missing closure devices (dogs), causing PSCOs to call into question the suitability of the current securing arrangements for the cargo tank butterworth hatches as they are not as originally designed and constructed. (74 SOLAS 14 VII/10.1 REF IBC 1.5.3) (40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2017
Resolved 12 October 2017
Resolution: PSC HOU recieved DNV-GL Class report satisfying requirements.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 26 July 2017 Resolved
PSCO observed pressure of 34.5 kPA in #7P cargo tank, exceeding the high pressure alarm (set at 22 kPA) by 160%, causing the PSCOs to call into question the structural adequacy of the #7P cargo tank and the sufficiency of the primary and secondary means of over-pressurization protection. (74 SOLAS 14 VII/10.1 REF IBC 8.3.3) (17ac) (see M # 6220181 for full deficiency)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2017
Resolved 30 July 2017
Resolution: Cause of over pressurization was found to be a shipping grommet that had become stuck in the P/V valve, reducing the functional cross sectional area of the discharge pipe. Visual and hydro pneumatic inspection of #7P cargo tank carried out.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 26 July 2017 Resolved
Company's SMS requires that during cargo operations the audible alarm for the high vapor pressure alarm must not be disabled. Upon entering CCR PSCOs observed that the high pressure alarm for the #7P cargo tank was activated, but the audible alarm was silenced. (74 SOLAS 14 IX/3.1 REF ISM 6.4) (17ac) (see M # 6220181 for full deficiency)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2017
Resolved 30 July 2017
Resolution: Received copy of external ISM-SMC audit report. See activity # 6220181 for amplifying information.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 29 June 2017 Resolved
Vessel failed to accurately submit an Advanced Notice of Arrival within the required timeframe.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 30 June 2017
Resolution: Vessel was issued a Notice of Violation for their improper NOA submission.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.