MAURY USCG vessel records Sign in
← All vessels

CHEMBULK KOBE

CHEMBULK KOBE is a 2002 tank ship. The Coast Guard has recorded 57 inspections since 2002, most recently in July 2019, along with 19 deficiencies and 27 operational controls, 1 with no removal date recorded.

Records from 2002 to 2019. Most recent: inspection, 12 July 2019.

Built
2002
Last inspected
12 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9263136 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
604744
Flag
MARSHALL ISLANDS
—
Maury page id
psix-604744

Inspections, by type

…with no type recorded30
Years with a record 13 calendar years (2002–2019)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11573 - Convention (Subpart B), Gross Ton
6084 - Convention (Subpart B), Net Ton
19996 - Dead Weight, Metric Ton
25281 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 57

12 July 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6747226
27 June 2019 Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6724172
27 June 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6457425
5 April 2018 COE-Dockside
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6384961
28 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6329870
17 December 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6325721
12 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6286569
27 July 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6222348
26 July 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6220181
29 June 2017 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6191170
21 June 2017 ISPS II Exam · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6183087
8 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6120056
7 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6121111
30 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6114469
24 March 2017 COE-Dockside
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6109678
2 February 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6081925
27 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6078404
12 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6020914
12 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6020947
1 August 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5959539
31 July 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5959526
30 May 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5883194
29 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5891069
29 May 2016 COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5891095
24 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5885356
27 January 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5804732
22 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5801673
20 January 2016 ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794265
16 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798570
16 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798700
1 August 2015 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5202913
21 July 2015 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5191564
18 March 2014 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4816241
5 January 2010 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3659115
3 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3427056
25 February 2009 MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex II Examination · COC-CHEM Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3421400
20 February 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3421094
20 February 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3421149
4 October 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3338357
25 September 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3332429
24 June 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3246860
28 January 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3137840
17 January 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3132010
14 January 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3129829
13 January 2008 Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex I Examination · ISPS II Exam · COC-CHEM Renew · Administrative Inspection · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3126590
12 January 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3129146
8 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3050731
5 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3050216
3 September 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3047347
10 May 2007 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2927231
28 February 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2879414
14 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2872381
10 May 2006 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2645285
10 March 2005 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2311393
4 March 2005 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · COC-CHEM Renew · Ballast Water Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2303272
29 December 2002 Security Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1737076
16 December 2002 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1720107

Deficiency record · 19

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 June 2019 Resolved
All the steering gear components shall be of sound and reliable construction. PSCO observed grinding noise emitting from steering gear when traveling between 0 and 5 degrees port and starboard on both steering pumps. 74SOLAS(04)II-1/29.2.1 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew cleaned the bearing grove of the rudder carrier and refilled with lubricant. Steering test was conducted without grinding noise. Deficiency rectified to satisfaction of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed numerous power cables improperly installed in connection boxes/electrical apparatus (conductors are pulled out of housing) 74SOLAS(04)II-1/45.1.3 50a
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew opened the gland fittings and cables were properly re-inserted and tightened. Deficiency rectified to satisfaction of class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Each vessel vapor connection flange must have a permanent stud projecting outward located at the top of the flange. PSCO observed port side manifold vapor connection flange stud as threaded and not permanently affixed. 46CFR39.2001(j) 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew welded the studs into the flange. Deficiency rectified to satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 June 2019 Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. Port State Control Examiners observed six capillary tube penetrations in the bulkhead between the ballast pump room lower section and engine room loose, not maintaining fire integrity. 74SOLAS(04)II-2/9.1.3 16a
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 12 July 2019
Resolution: Per DNV GL class report, the crew checked the pusher ring, packing, and plate in the bulkhead penetration gland and retightened thereafter. Fireclay was applied into the gland at pump room side to maintain fire integrity.
Lifesaving › Launching Appliances › Falls
Issued 17 December 2017 Resolved
Falls used in launchng shall be inspected periodically with special regard for areas passing through sheaves. During abandon ship drill the port side life boat was lowered to embarkation deck. The forward sheave on the forward arm is seized and did not rotate at all.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2018
Resolved 28 December 2017
Resolution: SEC HOU-GAL PSC Branch received a class report satisfying the requirement
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 July 2017 Resolved
Main and emergency switchboards shall be so arranged so the sides and rear are suitably guarded. Found approximately 6" by 18" unsealed openings on back of main switchboards and 6" x 18" unsealed openings on each side of emergency switchboard. (74 SOLAS 01 II-1/45.2) (50ac)
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 30 July 2017
Resolution: Received class report attesting that all openings have been fitted with sheet metal enclosures.
Construction/Loadline › Markings › Load Line Mark
Issued 27 July 2017 Resolved
The rings, lines, and letters shall be painted in white or yellow on a dark background. Load line renewal survey was carried out in June 2017 but the deck line is not painted a contrasting color to the hull. (ILLC Annex I/8) (50ac)
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 30 July 2017
Resolution: Received class report attesting to the fact that deck line has been painted a contrasting color to the hull.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 27 July 2017 Resolved
Cargo tanks must not be filled higher than the level at which an overfill alarm complying with 46 CFR 39.2007 or 39.2009(a)(2) is set. Vessel's overfill alarm for #6P cargo tank is continuously alarming. The set point for the vessel's overfill alarm is at an ullage of 1.234m and the current ullage of the tank is 1.07m. (46 CFR 39.3001(e)(2)) (40c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2017
Resolved 12 October 2017
Resolution: PSC HOU recieved DNV-GL Class report satisfying requirements.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 July 2017 Resolved
PSCOs found eight cargo tank butterworth hatches with broken or missing closure devices (dogs), causing PSCOs to call into question the suitability of the current securing arrangements for the cargo tank butterworth hatches as they are not as originally designed and constructed. (74 SOLAS 14 VII/10.1 REF IBC 1.5.3) (40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2017
Resolved 12 October 2017
Resolution: PSC HOU recieved DNV-GL Class report satisfying requirements.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 26 July 2017 Resolved
PSCO observed pressure of 34.5 kPA in #7P cargo tank, exceeding the high pressure alarm (set at 22 kPA) by 160%, causing the PSCOs to call into question the structural adequacy of the #7P cargo tank and the sufficiency of the primary and secondary means of over-pressurization protection. (74 SOLAS 14 VII/10.1 REF IBC 8.3.3) (17ac) (see M # 6220181 for full deficiency)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2017
Resolved 30 July 2017
Resolution: Cause of over pressurization was found to be a shipping grommet that had become stuck in the P/V valve, reducing the functional cross sectional area of the discharge pipe. Visual and hydro pneumatic inspection of #7P cargo tank carried out.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 26 July 2017 Resolved
Company's SMS requires that during cargo operations the audible alarm for the high vapor pressure alarm must not be disabled. Upon entering CCR PSCOs observed that the high pressure alarm for the #7P cargo tank was activated, but the audible alarm was silenced. (74 SOLAS 14 IX/3.1 REF ISM 6.4) (17ac) (see M # 6220181 for full deficiency)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2017
Resolved 30 July 2017
Resolution: Received copy of external ISM-SMC audit report. See activity # 6220181 for amplifying information.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 29 June 2017 Resolved
Vessel failed to accurately submit an Advanced Notice of Arrival within the required timeframe.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 30 June 2017
Resolution: Vessel was issued a Notice of Violation for their improper NOA submission.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 3 March 2009 Resolved
COTP order issued when notified that the vessel had lost propulsion while transiting.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2009
Resolution: Received Class report (BV) attesting to the cause of the loss of propulsion and attesting to the proper repairs. OP Con released.
Engineering › Diesel Engine (propulsion-electric) › Blower, Centrifugal
Issued 4 October 2008 Resolved
30SEP08 - Received notification that the vessels #2 Main Engine Auxiliary Blower is inoperable. Prior to departure vessel must make permanent repairs to the #2 Main Engine Auxiliary Blower, to the satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2008
Resolved 4 October 2008
Resolution: Received Class Report attesting to the proper repair and operation of the #2 Main Engine Auxiliary Blower.
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 January 2008 Resolved
28Jan08-The Chembulk Kobe requested an inbound deviation for there secondary radar. Prior to the removal of the operation control placed upon the vessel, they must issue a class report attesting to the proper functionality of their secondary radar.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2008
Resolution: The Vessel submitted a technicians report attesting to the proper operation of the Secondary Marine Radar System.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 January 2008 Resolved
Vessel has an inoperable 2nd radar. Vessel required to repair radar prior to departing Sector Houston/Galveston.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2008
Resolution: Received a report from class attesting to the repairs made on the secondary radar.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 10 May 2007 Resolved
The high level alarms are not working in cargo tanks #3P and #9P. Rectify deficiency before next U.S port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 September 2007
Resolution: Received class report from Bureau Veritas satisfying requirement.
Engineering › Fuel Oil Service System › Filter
Issued 14 February 2007 Resolved
Vessel reported a loss of propulsion during inbound transit of Houston Ship Channel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2007
Resolution: Received satisfactory class report describing cause of power loss to be water in the fuel.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 March 2005 Resolved
Emergency generator starting batteries for #2 bank worn out and non functional.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 7 March 2005
Resolution: Receipt for new batteries received this date.

Ownership record