MAURY USCG vessel records Sign in
← All vessels

MSC HAITI II

MSC HAITI II is a 2001 public freight. The Coast Guard has recorded 52 inspections since 2002, most recently in May 2022, along with 18 deficiencies and 14 operational controls.

Records from 2002 to 2022. Most recent: inspection, 26 May 2022.

Built
2001
Last inspected
26 May 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9225251 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
604917
Flag
MARSHALL ISLANDS
—
Maury page id
psix-604917

Inspections, by type

…with no type recorded16
Years with a record 17 calendar years (2002–2022)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27839 - Convention (Subpart B), Gross Ton
13386 - Convention (Subpart B), Net Ton
37548 - Dead Weight, Metric Ton
48479 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

26 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7459572
2 December 2021 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7357693
2 December 2021 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7361360
14 July 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7255947
8 July 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7249746
28 February 2021 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7147932
24 February 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7145409
23 February 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7145171
23 February 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7200080
19 February 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7142846
28 October 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7085701
23 October 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7080771
27 June 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6988615
16 February 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6910006
12 February 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6908327
18 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6858002
12 November 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6854219
19 October 2019 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6837709
9 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6831136
6 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6829119
19 June 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6718858
14 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6719249
2 March 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6635192
23 January 2019 Administrative Inspection · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6613858
27 September 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6549883
19 January 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6340276
7 October 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6284391
21 February 2017 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6092159
14 February 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6088034
17 January 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6067650
13 September 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6000487
24 December 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5786739
1 September 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5231864
1 September 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5232427
1 September 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5233727
24 May 2012 Deficiency Check · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4314978
2 February 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4236904
21 January 2010 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3665022
27 February 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3425303
27 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3426770
23 February 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3422634
14 November 2008 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3363073
10 November 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3360940
19 February 2008 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3149549
29 March 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2612017
14 October 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2514782
21 April 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2340103
28 June 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2114455
24 February 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2012344
20 February 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2009670
5 November 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1942665
14 December 2002 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination · Security Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1718014

Deficiency record · 18

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 February 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely impacted its fitness and capability to safely maneuver the Houston Ship Channel. Submit for review a Classification Society report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored. (60ac)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 February 2021
Resolution: Vessel submitted class report attesting to satisfactory repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 19 October 2019 Resolved
The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Vessel was issued ISM related deficiency on 19JUN2019 during Port State Control (see form B dated 19JUN2019 for further info) with a resolution due date of next U.S. port after sailing foreign. Vessel has sailed foreign and visited two ports since issuance of ISM deficiency dated 19JUN2019, making the deficiency overdue. Non-conformity report (SMS form D05 dated 19JUN2019) generated by the ship's crew was submitted to vessel's ISM company and has yet to provide a corrective action report. An internal safety audit and corrective action report is required. 74 SOLAS (14) IX/ 3.1 ref ISM Code 9.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2019
Resolution: Received email correspondence from vessel's ISM DPA addressing all outstanding items from previously conducted ISM internal audit.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 19 June 2019 Resolved
Oil filtering equipment of this regulation shall be arranged to ensure any discharge of oily mixtures is automatically stopped when oil content exceeds 15PPM. Oil filtering equipment is capable of operating in overboard discharge mode without pulling a sample from the oil content meter.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 June 2019
Resolved 28 August 2019
Resolution: PSC NOLA received a class report from RINA satisfying the requirement
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 June 2019 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained and ready for use. The vessel's fire detector located in purifier space was covered and multiple Class "A" doors in machinery space were tied open with hold-backs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 June 2019
Resolution: Vessel removed covering and hold-backs
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 June 2019 Resolved
The company should establish procedures to ensure the ship is maintained with provisions and relevant rules and regulations. Deficiency #2 is objective evidence ships inspection procedures are inefective. Ship's Form 5.01b was filled out March 2019 and blocks 3.2 and 3.12 were marked as "good"
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 November 2019
Resolution: Received Safety Meeting notation and revision of ISM procedures from the vessel showing change in procedures to the satsifcation of the organization.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2019 Resolved
07109- Fixed Fire Extinguishing Installation- Fire Protection systems and fire fighting systems and appliances shall be maintained ready for use. In CO2 room, a hose was found to be leaking and another cylinder was missing a hose. PSCO observed some deterioration of hoses. -74SOLAS(14 Cons.) II-2/14.1.1
Action required: 10 - Deficiency Rectified
Due 24 January 2019
Resolved 24 January 2019
Resolution: Ships crew was able to tighten hose,replace, and ass hoses where needed. Captain showed request for new hoses on 15JAN2019 to be installed when received.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 22 February 2017 Resolved
Ships shall be maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. An excessive jacket water leak was discovered on the number five cylinder on the main engine.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2017
Resolved 23 February 2017
Resolution: Class Surveyor attended vessel, confirmed repairs, and noted no leakage. See documents tab for more information.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 21 February 2017 Resolved
WHENEVER AN ACCIDNET OCCURS TO A SHIP OR A DEFECT IS DISCOVERED WHICH AFFECTS THE SAFETY OF THE SHIP OR THE EFFICIENCY OR COMPLETNESS OF ITS EQUIPMENT, THE MASTER OR OWNER SHALL REPORT TO THE ADMINISTRATION, SURVEYOR OR RECOGNIZED ORGANIZATION, WHO SHALL CAUSE INVESTIGATIONS TO BE INITIATED. THE VESSEL REPORTED TO PSCO A REDUCTION IN PROPULSION AND THE ABILITY FOR THE MDE TO RUN ON 5 CYLINDERS
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 21 February 2017
Resolved 22 February 2017
Resolution: RECIEVED CLASS REPORT ATTESTING TO PROPER FUNCTIONING M/E NO.2 CYCLINDER.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 5 January 2016 Resolved
0610-Lifeboats- Life saving appliances shall be in working order and ready for immediate use. Crew took more than 30 mintues to start lifeboat and had to change out batteries in order to achieve starting. SOLAS III/19.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 5 January 2016 Resolved
0750-Fire Prevention. Ship shall be maintained to proceed to sea without danger to the crew or ship. Oily rags were discovered all over the engineering spaces both in and outside approved containers. All recpticals were full and more than 10 55 gallons drums of oily rags were being stored within the steering space. SOLAS I-11.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2016 Resolved
0750-Fire Prevention. Ship and equipment shall be maintained and ready fto proceed to sea without danger to crew or ship. Electrical wiring throuout the enginroom was substandard in cluding #2SSDG, MDE Cooler Thermo Probs, Slop tank electrical distrubution box was hanging by wires, main seawater pump (440v) and Engineroom Eductor Pump (440v) were missing stuffing for electrical conduit. SOLAS I/11
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 7 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 January 2016 Resolved
2420-SULFER LIMITS FOR WORLD WIDE USE. Ship was conducting ECA change over however was lacking the procedures required for change over. CE was doing it from memory and hadn't standardize procedures. He drafted up procedures prior to exam completion. MARPOL VI/REG 14/6
Action required: 705 - Other - as specified
Due 5 January 2016
Resolved 5 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 5 January 2016 Resolved
9900-Other not clearly hazardous. Master, owner, operator, agent or person in charge shall maintain ballast plan addressing the removal of fouling organisms from the vessels hull. 33CFR151.2050(f).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Pollution Prevention/Response › Response Equipment › Non-sparking Hand Scoops/Shovels/Buckets
Issued 5 January 2016 Resolved
1799-Other Marpol Annex 1. Every ship 400 gross tonnage and aboive shall carry on board a shipboard oil pollution emergecny plan. Vessl was missing required response equipment including the plastic shovesl. MARPOL I/37.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 5 January 2016 Resolved
0750-Fire Prevention. Doors in fire resiting division in cargo ships are required to have doors of the self closing type not fitted with hold backs unless they are of the fail safe type. Vessel was keeping the Emergency Generator Door (B-0) tied in the open postion. SOLAS II/2/9.4.2.2.
Action required: 705 - Other - as specified
Due 5 January 2016
Resolved 7 January 2016
Resolution: Recieved RINA Class Survey stating that deficiency has been corrected.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2009 Resolved
4ft by 4ft by 1.5ft deep inset located on starboard bow in way of forepeak ballast tank. Provide class report indicating extent of damage and corrective action to be taken within 60 days. Solas Consolidated 2004, Ch II-1, Reg 3-1.
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 27 February 2009
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 23 February 2009 Resolved
Incinerator not operational, preventing ship from incinerating sludge. Provide class report proving correct operation of incinerator within 60 days. Marpol, Annex 1, Reg 21.1.
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 27 February 2009
Resolution: Received report from the Rina Class Society that they had verified parts were on order for the incinerator and that class would also perform an operational test of the incinerator once it had been repaired.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 November 2008 Resolved
MASTER REQUEST LOD FOR MARINE SURFACE SYSTEM FOR SURFACE NAVIGATION AND ADDITIONAL OPERABLE RADAR THAT OPERATES INDEPENDENTLY OF THE FIRST.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2008
Resolution: See attached Tech Report. Radar is operational and safe for navigation.

Ownership record