MIDNIGHT SUN

MIDNIGHT SUN is a 2002 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in March 2026, along with 13 deficiencies, 1 operational control and 4 casualty investigations between 2008 and 2011.

Records from 2008 to 2026. Most recent: inspection, 31 March 2026.

Built
2002
Last inspected
31 March 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDE6205
605105
Flag
UNITED STATES
Maury page id
psix-605105

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 173 / net 62
BuilderTRI-STATE STEEL · LA CROSSE, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it173 - Convention (Subpart B), Gross Ton
76 - Regulatory (Subpart C or D), Gross Ton
62 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

31 March 2026 In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8333693
24 February 2026 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8311114
16 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8153381
13 June 2024 Examination of Repairs · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7933849
28 March 2024 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7888232
6 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7704267
24 May 2022 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7458256
18 March 2022 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414042
3 March 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7149492
18 June 2020 Spot Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6981183
10 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6972748
28 February 2020 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6919880
3 June 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6701806
30 April 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6397528
13 March 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370998
26 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6295294
25 October 2017 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 6295564
30 May 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6159808
18 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5835800
7 March 2016 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5828150

Deficiency record · 13

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2025 Resolved
Marine employers must ensure that data submitted by a consortium or other employer representative under paragraph (b)(3) of this section is correct. Consortium report was found to have a licensed mariner listed as unlicensed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles are constructed of combustible material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Replaced with metal
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 June 2025 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Flame screen missing on fuel tank vent pipe.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Sceen installed inside of pipe
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Seawater piping in engine room and steering compartment was found utilizing single hose clamps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Double hose clamps utilized on vital systems
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 June 2025 Resolved
Watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH—KEEP CLOSED”. Aft hatch missing label.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Labeled as required
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 16 June 2025 Resolved
Gauges to indicate engine jacket water discharge temperature must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Starboard engine jacket water discharge temperature gauge not working properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Sending unit replaced with new
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 June 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Bilge alarm in lazarette not working.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Replaced pannel for indicator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessels more than 65' are required to have 2 fixed power pumps rated at 50GPM. Bilge pump installed on starboard engine not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Replaced entire bilge pump assembly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2025 Resolved
Starting motors, generators, and any spark producing device must be mounted as high above the bilges as practicable. Aft sewage pump not mounted as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2025
Resolved 22 July 2025
Resolution: Pump properly mounted
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 June 2023 Resolved
46 CFR 181.300 (a)(i): On a vessel of more than 65 ft. in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure not less than 60 psi. at the pump outlet. MI observed a broken flex hose at the outlet of the fire pump and at the engine driven water pump which were flooding the engine room. Repair to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2023
Resolved 7 June 2023
Resolution: Piping and hoses replaced, and tested. All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 June 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 6 September 2023
Resolution: Received a copy of radio operators permit, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 March 2022 Resolved
Starboard aft main deck scuttle sealing surface was wasted and not providing proper watertight closure. Provide repair proposal and repair/replace in accordance with approved marine practices.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2022
Resolved 6 April 2022
Resolution: Repairs completed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 October 2017 Resolved
Port and Starboard navigational lights inoperative.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2017
Resolution: Vessel repaired port and starboard navigational lights.

Casualty record · 4

18 March 2008Routine · role: Involved in a Marine Casualty · activity 3168875
6 June 2009Routine · role: Involved in a Marine Casualty · activity 3617966
11 August 2009Routine · role: Involved in a Marine Casualty · activity 3577948
8 October 2011Routine · role: Involved in a Marine Casualty · activity 4164752
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MIAMI MAGIC (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.