This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it28048 - Convention (Subpart B), Gross Ton 54674 - Displacement, Ton 45861 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
7 July 2016COC-TVE Renew · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5929162
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 7 July 2016Resolved
Electrical 0950-Each emergency generating set arranged to be automatically started shall be provided with a stored energy capability of at least 3 consecutive starts and a second source of energy for an additional 3 starts within 30 minutes unless manual starting can be demonstrated to be effective.PSCO observed crew was unable to start the emergency generator using secondary source of energy. 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2016
Resolution: Attended vessel and observed starting and operation of emergency generator utilizing two sources of energy. Battery banks were replaced and are fully operational.