MAURY USCG vessel records
← All vessels

PATRIOT II

PATRIOT II is a 2002 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in April 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 2 April 2026.

Built
2002
Last inspected
2 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

605570
Flag
UNITED STATES
Maury page id
psix-605570

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

2 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8341023
25 March 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8092695
8 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7895920
20 April 2023 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7654783
9 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7412267
23 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7162107
28 April 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6883467
18 March 2019 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6644650
15 February 2018 Hull Examination · DAPI Audit · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6355559
9 July 2017 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6166199
27 June 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5869841

Deficiency record · 14

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025 Resolved
A Small Passenger Vessel must have one ring life buoy with one floating water light and must be attached to the lanyard with a corrosion-resistant clip. Each floating water light must be approved in accordance with CG 161.010. The water light was not operational when tested. Repair or replace the water light and demonstrate proper operation to a Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 14 April 2025
Resolution: Owner provided photographic evidence that a new light was purchased, burning brightly and affixed with a lanyard to the Life Ring Buoy.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 25 March 2025 Resolved
A ship, except a ship of less than 26 feet in length, must have an “Garbage Discharge” placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place. The vessel did not have a placard on board and posted in a conspicuous place. Provide and post a “Garbage Discharge” placard in a conspicuous and visible place to the satisfaction of a Coast Guard Marine Inspector
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 14 April 2025
Resolution: Owner provided photographic evidence that garbage placard was properly posted.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2023 Resolved
A vessel on Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter and Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. As a substitute option A hand red flare distress signal approved in accordance with § 160.021 in subchapter Q of this chapter may be substituted for any of the hand orange smoke distress signals. Flares were expired. The vessel will be restricted from carrying passengers after May 20th, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard MI.46CFR180.68
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 8 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2023 Resolved
Portable watertight containers for distress flares smoke signals. Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Container not onboard. The vessel will be restricted from carrying passengers after May 20th, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard MI.. 46CFR185.614
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 8 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) see 46 CFR 175.600). 3 life jackets retroreflective material is deteriorated and needs to be replaced. The vessel will be restricted from carrying passengers after May 20th, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard MI. 46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 8 May 2023
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 20 April 2023 Resolved
Provide and post a MARPOL V, garbage placard in accordance with 33 CFR 151.59. The vessel will be restricted from carrying passengers after May 20th, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 8 May 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 April 2019 Resolved
10109 Vessel is under 20m and the one masthead light is not as far as practical forward as required by as required by 33 CFR84.03(d). Move mast head light as far forward as practical. 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 29 May 2019
Resolution: Received Pictures as evidence of repairs, Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2019 Resolved
13199 Vessels fuel hoses are not installed with two clamps at both ends of the hose as required by 46 CFR 182.220 (V)(B). Install proper amount of hose clamps on fuel hoses. 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 29 May 2019
Resolution: Received Pictures as evidence of repairs, Sat
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 8 August 2017 Resolved
Provide at least one additional red hand flare or one additional orange smoke signal to make the total distress signals six (06) onboard in accordance with 46 CFR 180.68.
Due 22 August 2017
Resolved 8 September 2017
Documentation › Markings/Placards › Oil Discharge Placard
Issued 8 August 2017 Resolved
Provide and post an oil discharge placard in a conspicuous place in accordance with 33 CFR 155.450.
Due 22 August 2017
Resolved 8 September 2017
Documentation › Markings/Placards › Garbage Placard
Issued 8 August 2017 Resolved
Provide a garbage placard and post in a conspicuous place in accordance with 33 CFR 151.59.
Due 22 August 2017
Resolved 8 September 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2017 Resolved
Either replace all the expired medication in the first aid kit and ensure the quantities meet 46 CFR 160.041 or provide a new first aid kit that is approved under 46 CFR 160.041.
Due 22 August 2017
Resolved 8 September 2017
Operations/Management › Vessel Activity › Other
Issued 9 July 2017 Resolved
Vessel has exceeded 3 month window to complete an Annual Inspection and does not meet the minimum requirement of a vessel' must complete an annual inspection within 3 months before or after each anniversary date (9APR) as indicated on their current Certificate of Inspection as required by 46CFR176.500(b)(1). Vessel is restricted from operating with passengers until vsl completes annual insp.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2017
Resolution: Annual inspection was completed on this date.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 28 June 2016 Resolved
Vessel had only one (01) B-I portable fire extinguisher onboard at the time of the inspection. The vessel is required to have a total of two portable fire extinguishers in accordance with the Certificate of Inspection dated April 9, 2013 and in accordance with the table of minimum portable fire extinguishers in 46 CFR 181.500(a). Provide and properly mount one B-II fire extinguisher PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 11 July 2016
Resolution: Master provided a receipt for the new B-II protable fire extinguisher.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.