MAURY USCG vessel records
← All vessels

SEASPAN 880

SEASPAN 880 is a 2003 tank barge. The Coast Guard has recorded 39 inspections since 2003, most recently in May 2018, along with 30 deficiencies, 2 operational controls and 5 casualty investigations between 2004 and 2012.

Records from 2003 to 2018. Most recent: inspection, 25 May 2018.

Built
2003
Last inspected
25 May 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 25 May 2018
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2003–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

606057
Flag
UNITED STATES
Maury page id
psix-606057

Documentation record

Tonnage as PSIX records it5954 - Convention (Subpart B), Gross Ton
2822 - Convention (Subpart B), Net Ton
12196 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

Inspection history · 39

25 May 2018 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6420539
4 April 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117195
15 August 2016 Examination of Repairs · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5974101
29 February 2016 Internal Structural Exam · Deficiency Check · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821804
17 September 2015 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5725498
19 March 2015 Annual Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5089636
14 December 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5039937
25 July 2014 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4933536
10 July 2014 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4909837
10 June 2014 Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4884896
1 May 2014 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4848530
18 March 2014 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4818668
7 March 2014 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4812159
10 October 2012 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4461318
5 October 2012 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4458089
13 September 2012 Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4440967
12 September 2012 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4439515
19 April 2012 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4388318
25 January 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4231812
21 December 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3917973
18 December 2010 Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3913671
29 April 2010 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3723232
18 March 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3436368
2 March 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3432175
9 January 2009 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3391525
15 July 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3268720
12 July 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3274733
12 May 2008 COI Inspection · Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3204940
8 October 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3076422
23 May 2007 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2936677
27 October 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2849631
30 May 2006 Annual Inspection · Internal Structural Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2658780
22 June 2005 Periodic Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2399510
9 June 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2439263
2 August 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2153516
19 July 2004 MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2138550
23 January 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1994179
3 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958301
8 May 2003 Hull Examination · Internal Structural Exam · MARPOL Annex I Examination · MARPOL Annex II Examination · COI Inspection · Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1789157

Deficiency record · 30

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Loading Arms
Issued 14 April 2016 Resolved
Cargo transfer hoses are past due for hydro testing. Prove hydro testing of cargo hoses prior to use.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 14 April 2016 Resolved
#5P COT overfill alarm is inop. Prove operation of alarm.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Deck/Cargo › Cargo Stowage › General
Issued 14 April 2016 Resolved
Fracturing of cargo tanks IWO Fr.s has resulted in multiple inserts to cargo tanks. Conduct non-destructive testing to determine the presence of subsurface defects in cargo tanks that have not inserted to include Fr.s 7P/S, 8P, 9P, 10P/S, 11P, 13P, 40S, 41P/S, 42S, 44S, 45P/S. Testing shall be conducted by a 3rd party and results submitted to Coast Guard and attending ABS surveyor for review.
Due 29 April 2016
Resolved 29 April 2016
Resolution: All remaining Fr.s were inserted IWO COT's.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 February 2016 Resolved
Fwd void - C&R damaged bracket IWO SL2(stbd) and aft bulkhead.
Due 29 April 2016
Resolved 9 March 2016
Construction/Loadline › Hull › Girder
Issued 29 February 2016 Resolved
Void No. 1 Stbd - C&R deep transverse web from SL1 to SL4.
Due 29 April 2016
Resolved 9 March 2016
Construction/Loadline › Hull › Stringer
Issued 29 February 2016 Resolved
Void No. 1 Stbd - C@R BL's 1&3 from fwd blk aft 36" and renew brackets. BL's 2&4 from fwd blk aft 48" and renew brackets.
Due 29 April 2016
Resolved 18 March 2016
Construction/Loadline › Hull › Stringer
Issued 29 February 2016 Resolved
Void No. 1 Port - C@R BL's 1&3 from fwd blk aft 36" and renew brackets. BL's 2&4 from fwd blk aft 48" and renew brackets.
Due 29 April 2016
Resolved 18 March 2016
Construction/Loadline › Hull › Hull Plating
Issued 18 March 2014 Resolved
Provide repair proposal for Coast Guard review, then conduct repairs once approved.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2014
Resolution: Repairs satisfactory.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2014 Resolved
After every Ocean Transit, an inspection shall be conducted in all voids to examine the cargo tank shells. Inspect each frame joint on the out-board sides of the cargo tank knuckles for signs of cracking and leaks. This inspection shall be documented and submitted to Sector San [name withheld] Inspections via e-mail to: [email withheld]
Condition: Design Flaw
Due 2 May 2014
Resolved 9 May 2014
Resolution: Company has failed to comply with requirement. Issued more restrictive 835.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2014 Resolved
Provide a structural analysis to determine the cause of frequent cracking in the outboard sides of the cargo tank knuckle plating. Analysis shall address all cargo tank fractures noted during dry-dock of 2013 and all that were found in March of 2014. Causative factors for all cracks should be identified.
Condition: Design Flaw
Due 2 May 2014
Resolved 9 May 2014
Resolution: Company has failed to comply with requirement. Issued more restrictive 835.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2014 Resolved
Provide a proposed corrective action plan to prevent future cracking.
Condition: Design Flaw
Due 2 May 2014
Resolved 9 May 2014
Resolution: Company has failed to comply with requirement. Issued more restrictive 835.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2014 Resolved
At least once every 90 days, an inspection shall be scheduled with the cognizant OCMI. A Marine Inspector will conduct internal structural exams of all voids to inspect the cargo tank shells. Each frame joint on the outboard sides of the cargo tank knuckles will be inspected carefully for signs of cracking and leaks. Exams shall be conducted until structural repairs have been approved & completed
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 15 March 2016
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2014 Resolved
Provide a structural analysis to determine the cause of frequent cracking in the outboard sides of the cargo tank knuckle plating. Analysis shall address all cargo tank fractures noted during dry-dock of 2013 and all that were found in March of 2014. Causative factors for all cracks should be identified.
Condition: Improper/Lack of Maintenance
Due 30 July 2014
Resolved 22 July 2014
Resolution: Structural analysis has been submitted to ABS for review under NVIC 10-82.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2014 Resolved
Provide a repair proposal to prevent future cracking of cargo tank structures.
Condition: Design Flaw
Due 30 July 2014
Resolved 22 July 2014
Resolution: Repair proposal has been submitted.
Deck/Cargo › Cargo Stowage › General
Issued 18 March 2014 Resolved
Offload all cargo, clean area adjacent to identified crack in cargo hold #3 and certify spaces safe for hot work.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2015
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 18 March 2014 Resolved
Provide repair proposal for identified crack and affect repairs in accordance with USCG approved repair proposal to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2015
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 March 2014 Resolved
Make void 1 available for internal exam at the vessel's next port call to San Francisco Bay (after 01 September 15) for the purpose of monitoring the fractured bottom longitudinal frames at bulkhead 6 and the outboard longitudinal to web frame weld fractures.
Action required: 705 - Other - as specified
Resolved 1 November 2015
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 7 March 2014 Resolved
Conduct survey and adequate repairs in accordance with all applicable ABS rules in the #3 and #5 double bottom voids.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2014
Resolution: Received report from Elliot Bay which can be viewed in documents section of VCP.
Construction/Loadline › Structures › Superstructure
Issued 13 September 2012 Resolved
Crop and renew fractured bulkhead in way of #1 P tank forward above the main deck near centerline.
Action required: 705 - Other - as specified
Due 13 October 2012
Resolved 11 October 2012
Resolution: Fractured bulkhead renewed with weld procedure attached to activity 4461318.
Construction/Loadline › Hull › Stiffener
Issued 13 September 2012 Resolved
Renew wasted/fractured welds for stiffener brackets fwd of #1 S and #1 P tank bulkheads on/above the main deck.
Action required: 705 - Other - as specified
Due 13 October 2012
Resolved 10 October 2012
Resolution: Attended renewed welds for stiffener brackets forward of #1 S and #1 P tanks.
Construction/Loadline › Hull › Stiffener
Issued 13 September 2012 Resolved
Vessel must conduct repairs after offloading all cargo. A marine chemist must certify tanks safe for hot work. No cargo may be loaded until repairs are made.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2012
Resolved 11 October 2012
Resolution: Repairs complete and vacuum box testing satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 December 2010 Resolved
Submit plan for approval, to repair the following tripped/fractured internal structures: Bottom longs and bulkhead brackets in fwd rake; bottom longs in port side #1 double bottom void; 2nd sideshell long from bottom and bulkhead bracket in #1 port wing void. See activity narrative and/or on board handwritten CG 835 for specific locations.
Due 18 February 2011
Resolved 3 February 2011
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 28 May 2008 Resolved
Vapor control lines need to be labeled with red yellow red markings with black VAPOR lettering over yellow section.
Condition: Design Flaw
Due 2 June 2008
Resolved 28 May 2008
Construction/Loadline › Structures › Door
Issued 28 May 2008 Resolved
Gasket on generator ventilation door needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 30 May 2008
Resolved 28 May 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 May 2008 Resolved
Port side red navigation light and yellow pushing ahead light need to be repaired and operable.
Due 30 May 2008
Resolved 28 May 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 May 2008 Resolved
Blue loss of power light needs to be repaired.
Due 30 May 2008
Resolved 28 May 2008
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 28 May 2008 Resolved
Overfill alarm does not have a seperate distinctive audible sound.
Due 30 May 2008
Resolved 28 May 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 May 2008 Resolved
Transfer piping needs to be hydrostatically tested and stamped.
Condition: Improper/Lack of Maintenance
Due 30 May 2008
Resolved 28 May 2008
Construction/Loadline › Hull › Bracket
Issued 12 May 2008 Resolved
Repair 3 tripped and corroded brackets in starboart bow rake.
Condition: Damaged By Earlier Event
Due 30 May 2008
Resolved 16 May 2008
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 23 May 2007 Resolved
Provide copy of updated Below Deck Piping Diagram in the Oil Transfer Procedures.
Due 23 May 2007
Resolved 23 May 2007
Resolution: Corrected on the spot.

Casualty record · 5

23 January 2004Routine · role: Involved in a Marine Casualty · activity 1994179
8 October 2007Routine · role: Transiting Vicinity of Primary Subject · activity 3076422
2 March 2009Routine · role: Involved in a Marine Casualty · activity 3432175
21 December 2010Routine · role: Subject to Marine Inspection · serious marine incident, as classified · activity 3917973
12 September 2012Routine · role: Acknowledged Pollution Source · activity 4439515
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LEO (2004–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.