KEMPTON

KEMPTON is a 2000 tank ship. The Coast Guard has recorded 9 inspections since 2018, most recently in June 2021, along with 11 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 2018 to 2021. Most recent: inspection, 23 June 2021.

Built
2000
Last inspected
23 June 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 June 2021
…with no type recorded3
Operational controls 1 with no removal date recorded
Years with a record 3 calendar years (2018–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9229142
606222
Flag
PANAMA
Maury page id
psix-606222

Documentation record

Tonnage as PSIX records it8193 - Displacement, Metric Ton
4999 - Dead Weight, Metric Ton
5246 - Convention (Subpart B), Gross Ton
1573 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

23 June 2021 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7233863
6 April 2021 Appeal
Administrative · Commandant (CG-CVC) · Activity 7175910
12 January 2021 ISM Exam · PSC B · Ballast Water Examination · Deficiency Check · COC-GAS Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7119804
18 May 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6687052
18 May 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6687066
16 April 2019 ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6659173
22 January 2019 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6605710
22 December 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6629849
9 December 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6594453

Deficiency record · 11

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 January 2021 Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the code to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs noted substantial wastage and corrosion throughout the cargo piping system which included 04 cargo leaks that were actively leaking propane into the atmosphere. Specifically, one leak was found on the purging valve of the #2 cargo tank’s discharge line, two leaks on #2 tank discharge line, and one leak was found above the #2 cargo tank on the vapor line for re-liquefaction. 74SOLAS(14) VII/13.1; 1993 IGC 1.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 January 2021
Resolution: PSCO's inspected the piping that previously had leaks and found no leaks.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 January 2021 Resolved
At all levels of accommodation there shall be provided at least two widely separated means of escape. Port side "A" deck door, which is one of the required means of escape, is seized. 74SOLAS(01) II-2/45.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 January 2021
Resolution: PSCO's observed satisfactory test of port WTD on "A" deck.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 January 2021 Resolved
All gasketed pipe joints and hose connections should be electrically bonded. Bonding straps throughout the cargo deck were found broken, wasted, and generally not connected to keep the piping electrically continuous. 74SOLAS(14) VII/13.1; IGC 1993 5.2.1.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 January 2021
Resolution: PSCO's observed thorough replacement of electrical bonding throughout the cargo deck.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 January 2021 Resolved
Emergency shutdown valves in liquid piping should fully close under all service conditions within 30 seconds of actuation. Emergency shutdown valve on the liquid line at the starboard manifold could not close automatically due to hydraulic supply line being disconnected. 74SOLAS(14) VII/13.1; IGC 1993 5.6.4
Condition: Invalid
Action required: 30 - Ship detained
Resolved 25 January 2021
Resolution: PSCO witnessed satisfactory test of ESD.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 January 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. Further, the vessel underwent a drydock period in November, 2020. PSCOs found substantial steel wastage throughout all areas of the ship, including cargo and fire main piping, decks, bulkheads, stairways, and walkways. The company failed to ensure that adequate repairs were made to the structure of the ship during the drydock. PSCOs also requested SMS procedures and manufacturer's specifications for calibration of the fixed gas detection system. The crew did not provide these documents to PSCOs after multiple requests. An external audit conducted by the Flag or RO is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port. 74SOLAS(14) IX/3.1; ISM CODE 10.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 25 January 2021
Resolution: PSCO received audit report from class (BV).
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 January 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Deteriorating conditions were noticed by PSCOs while conducting external deck walk on vessel. Corrosion on main deck as well as extreme wastage on the stairs and rails of exposed walkways is a concern for crew safety. 74SOLAS(14) I/11(a)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: Received Class report attesting to satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 January 2021 Resolved
Maintenance, testing and inspections shall be carried out based on guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Extensive corrosion was found throughout the fire main system on the main deck. 74SOLAS(14) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: Received Class report attesting to satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 January 2021 Resolved
In a ship which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and person on board. PSCO's observed numerous sections of oil soaked and frayed lagging throughout multiple piping systems in the engine room. 74SOLAS(01) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 25 January 2021
Resolution: PSCO observed oil-soaked lagging replaced satisfactorily.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 January 2021 Resolved
Each cargo tank should be fitted with a high liquid level alarm operating independently of other liquid level indicators and giving an audible and visual warning when activated. PSCOs observed test of high level alarm and found the alarm was not audible on deck 74SOLAS(14) VII/13.1; IGC 1993 13.3.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 25 January 2021
Resolution: PSCO witnessed proper function of tank level alarms on deck.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 January 2021 Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the code to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed/heard the supply fan for ventilation located in the motor room in the forward portion of the vessel hitting metallic sounding debris. This is located inside an intrinsically safe area and after approximately two minutes of operations, the venting emitted small amounts of smoke into the space. 74SOLAS(14) VII/13.1; 1993 IGC 1.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 25 January 2021
Resolution: PSCO observed the fan operating properly with no debries or smoke.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 January 2021 Resolved
Efficient guard rails or bulwarks shall fitted to all exposed parts of the freeboard and superstructure decks. PSCOs observed multiple sections of wastage through the bottoms of handrails on the aft decks of the vessel from A deck up to the bridge. ICLL ANNEX I II/25
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 June 2021
Resolution: Received Class report attesting to satisfactory repairs.