Records from 2003 to 2017. Most recent: inspection, 3 September 2017.
Inspection history · 24
3 September 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6256947
7 April 2017
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6119906
18 March 2017
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6109633
19 January 2017
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6073411
6 October 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6017799
14 August 2016
Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5968243
28 August 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5223280
25 February 2011
ISPS II Exam · NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3950227
29 April 2009
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3463703
10 March 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3431136
4 March 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3427353
2 March 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3426317
15 January 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3394889
15 December 2008
Loadline Exam · Deficiency Check · Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · ILO-147 Exam · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3379849
17 April 2008
ISM Exam · MARPOL Annex V Examination · Loadline Exam · ILO-147 Exam · MARPOL Annex I Examination · Administrative Inspection · STCW 95 Exam · Annual Inspection · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3186473
8 December 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3112021
5 November 2007
Random ISPS/MTSA-No PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3093135
12 October 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3078396
10 September 2007
ILO-147 Exam · Loadline Exam · Administrative Inspection · NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3054060
25 April 2007
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2915210
25 April 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2915417
4 August 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1868988
14 April 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1773375
21 January 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1733088
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 4 March 2009
Resolved
Vessel unable to exceed 60% power on MDE due to main engine high temperature alarms. Make repairs to the satisfaction of class and provide class report to local CG office.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2009
Resolution: Vessel provided class report stating that engine was repaired to their satisfaction.
Construction/Loadline › Markings › Load Line Mark
Issued 17 April 2008
Resolved
Load line mark not in accordance with certificate/ Rectify deficiency within 30 days to the satisfaction of class and coast guard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 30 June 2008
Resolution: Received class report via fax. The class report stated that the M/V Reykjafoss was found in non-compliance with their present valid load line certificate. For the time being the letter "F" has now been painted on and temporarily accepted.
Documentation › Manuals/Policy Documentation
Issued 21 January 2003
Resolved
49 CFR 100-199 not onboard vessel.
Condition: Unknown
Due 16 February 2003
Resolved 21 January 2003
Resolution: CFRs were ordered and onboard prior to vessel''s departure.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 January 2003
Resolved
Waste oil gauge not working in engine control room. *Spoke with [name withheld] of GL - gauge to be repaired during next drydock - June 2004. Fax with info was received on Fri 11 Apr 03 by LT N Thomas. LEGACY COMPONENT DESC: Gauge
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 14 April 2003
Resolution: Received fax from [name withheld], GL-class, attesting that gauge can not be repaired until next scheduled drydock on June 2004. There are still two ways to sound waste oil tank. 1) manual sounding by sounding pipe and 2) by high level alarm.