Records from 2003 to 2012. Most recent: inspection, 7 February 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
7 February 2012
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4232083
5 February 2011
ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3937825
11 February 2010
COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3675851
9 February 2009
COC-TVE Renew
Administrative · Activities Europe · Activity 3412759
18 March 2008
ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3161815
2 May 2006
MARPOL Annex V Examination · COC-TVE Renew · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2638959
4 February 2005
COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2286749
8 February 2004
Ballast Water Examination · Annual Inspection · Tank Vessel Examination · MARPOL Annex I Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2002550
8 January 2003
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1727744
Lifesaving › Buoyant Apparatus › Serviceable
Issued 9 February 2009
Resolved
Stbd. Side quick release lifebuoy, fitted with light and smoke, not able to be launched locally due to wasted by-pass valve. Port side quick release lifebuoy; fitted with light and smoke, not capable of being launched romotely or locally. Make proper repairs so as to restore operational reciness to the satisfaction of class prior to the next US port. 74 SOLAS 2004 cONS. III/7.1.3
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2009
Resolution: Class report clearing this discrepancy was received.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 February 2009
Resolved
Self closing fire damper for emergency diesel generator space, aft; found not closing properly. Make proper repairs to the satisfaction of Class prior to next U.S. port. 74SOLAS 2004 Cons. II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2009
Resolution: Class report clearing this discrepancy was received.
Deck/Cargo › Cargo Stowage › General
Issued 9 February 2009
Resolved
Properly label on-deck high level alarm and tank overfill alarm in black letters at least 2in. high to the satisfaction of USCG prior to next U.S. port. 46CFR39.20-7(c)(2) and (d)(3)
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2009
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 9 February 2009
Resolved
Properly vapor control lines in black letters at least 2in. high to the satisfaction of USCG prior to next U.S. port. 46CFR39.20-3(d)(2)
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 February 2009
Resolved
Oil water separator found fitted with a temporary repair, soft patch, on the discharge piping. Class to attest to suitability or temporary repair prior to next U.S. port. 73/78 MARPOL 2006 Cons. Annex I/6.4.1
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2009
Resolution: Class report clearing this discrepancy was received.
Lifesaving › Lifeboat › Hatches
Issued 9 February 2009
Resolved
Gasket material in way of entrances, port and stbd side, found wasted/missing. Lifeboats are no longer air tight as required. Make proper repairs to the satisfaction of Class prior to next U.S. port. 74SOLAS 2004 Cons. III/20.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2009
Resolution: Class report clearing this discrepancy was received.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 18 March 2008
Resolved
IGS temperature indication and high temp alarm/shutdown is not operational. correct to the satisfaction of the administration and prior to next U.S. port. PRIOR TO CARGO OPERATIONS IN THE U.S., Provide temporary alternative arrangement/procedures addressing IGS temperature monitoring that are to satisfaction of the administration and the U.S Coast Guard Officer in charge of Marine Inspections.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 5 May 2008
Resolution: Recieved a Class Report from Lloyds setting a condition of class of class until repair was completed. Recieved a second report that removed the condition of class after the system had been repaired, surveyed and found sat.