VICTORY is a 2002 freight ship. The Coast Guard has recorded 7 inspections since 2003, most recently in November 2007, along with 7 deficiencies — 4 with no resolution recorded — and 1 operational control.
Records from 2003 to 2007. Most recent: inspection, 14 November 2007.
- Built
- 2002
- Last inspected
- 14 November 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 4 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9238325 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6S2072
606613
Flag
BAHAMAS, THE
—
Maury page id
psix-606613
Inspections, by type
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22072 - Convention (Subpart B), Gross Ton
22072 - Regulatory (Subpart C or D), Gross Ton
11132 - Convention (Subpart B), Net Ton
11132 - Regulatory (Subpart C or D), Net Ton
34676 - Dead Weight, Ton
43735 - Displacement, Ton
22072 - Regulatory (Subpart C or D), Gross Ton
11132 - Convention (Subpart B), Net Ton
11132 - Regulatory (Subpart C or D), Net Ton
34676 - Dead Weight, Ton
43735 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
14 November 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3097846
12 September 2006
NPV Safety Exam · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2776184
15 March 2006
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2602835
7 July 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2116451
28 June 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2113422
7 January 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1727009
3 January 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1726907
Deficiency record · 7
Engineering › Compressed Air System (control) › Compressor
Issued 14 November 2007
No resolution recorded
Ship deck Service Air compressor is inoperable. VSL is using Main Enigine Start Air compressor for all ships service air. Provide class survey report attesting to repairs.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 November 2007
Resolved
Self closing fire doors for stair wells going to Main, A, B, + C decks will not self close and need adjusted. Additionally, self closing Fire door on the main deck from the machinery space to the changing room is inoperable due to broken /worn hangers and broken self closing mechanism. Inoperable fire doors create a potential hazard for fire growth.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 November 2007
Resolved
Self Closing fire door for fuel oil purifier room found wired open. Had C/E remove wire and close
Engineering › Fuel Oil Service System › Valve
Issued 14 November 2007
No resolution recorded
DeAirator relief valve in aft section of fuel oil purifier room is leaking. Ships crew has rigged a Funnel to catch the leak and channel into drain. Provide Class Report attesting to repairs.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 14 November 2007
No resolution recorded
Two wahing machines have been istalled in the engine room. the electrical wiring has splices and the power receptacle is moved from another location. Both Washing machines drain to the bilge and were recently installed by the ships crew. Provide class report attesting to the approval of the istallation
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 November 2007
No resolution recorded
No. 6 GSP Foreship fans breaker located on the mian switchboard in engine control room is tripped and will not reset creating a safety hazard.
Engineering › Fuel Oil Storage/Transfer System
Issued 7 January 2003
Resolved
Emergency generator remote fuel shutdown cablesystem was inoperative. When the cable was tested, an overhead fair lead for th ecable ripped out of the over head rendering it ineffective. The fairlead was originally connected to a false overhead that did not provide adequate support for the cable. LEGACY COMPONENT DESC: Valve