MAURY USCG vessel records Sign in
← All vessels

DAUNTLESS

DAUNTLESS is a 2001 freight ship. The Coast Guard has recorded 9 inspections since 2003, most recently in August 2015, along with 21 deficiencies.

Records from 2003 to 2015. Most recent: inspection, 25 August 2015.

Built
2001
Last inspected
25 August 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9263760 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
606621
Flag
PANAMA
—
Maury page id
psix-606621

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2003–2015)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16978 - Convention (Subpart B), Gross Ton
10498 - Convention (Subpart B), Net Ton
28473 - Dead Weight, Ton
34589 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

25 August 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5210452
9 August 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5221951
30 August 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4126761
4 September 2007 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3047632
23 May 2007 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2938210
24 August 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2758314
27 September 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2206334
13 January 2004 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1982933
17 January 2003 Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1733132

Deficiency record · 21

Fire Fighting › Firemans Outfit › Protective Clothing
Issued 25 August 2015 Resolved
0720 - Ships equipped with helidecks shall comply with the requirements of this regulation. In close proximity to the helideck, the following fire fighting appliances shall be provided and stored near the means of access to that helideck. the 01 additional fire fighting outfit is not onboard. The fire fighting outfits protective layers are wasted. 74 SOLAS (01) Cons. II-2/18.8. 30 abc See form B.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to attest to the receipt of fire fighting outfits onboard the vessel. All was found to be satisfactory and IAW the attending Classification Surveyor''s report.
Operations/Management › Drills/Instruction › Fire
Issued 25 August 2015 Resolved
2020 - Master and crew shall be familiar with essential shipboard procedures relating to the safety of the ship. Crew members failed 02 consecutive fire drills. During both drills crew members did not follow proper SMS procedures. Communications were not established, crew was unfamiliar with fire equip, additionally crew members were entering the same space of the fire with no PPE.30abc See Form B
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to observe fire drills. 01 successful fire drill was conducted, all was satisfactory.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 August 2015 Resolved
2199: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The marine sanitation device has leaks from 02 valves on the underside of the unit. Treated sewage is visibly seen dripping into containment. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to attest to the repairs/ modifications made to the vessel. All was found to be satisfactory and IAW the attending Classification Surveyor''s report.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 25 August 2015 Resolved
1499: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects remain fit to proceed to sea without danger to ship or persons on board. The A/C drain line to overboard has an unidentified modification to the system. Continued in narrative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to attest to the repairs/ modifications made to the vessel. All was found to be satisfactory and IAW the attending Classification Surveyor''s report.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 August 2015 Resolved
1400:The machinery,boilers,other pressure systems and associated piping and fittings shall be of a design and construction adequate for the service for which they were inteded. There are multiple steam line leaks coming from flanges and valves by the HFO settling tank. 74SOLAS(II-I/26) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to attest to the repairs/ modifications made to the vessel. All was found to be satisfactory and IAW the attending Classification Surveyor''s report.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 25 August 2015 Resolved
0330:The condition of the ship and its equipment shall be maintained and no changes shall be made in the structural arrangements,machinery,equipment and other items covered by the survey without sanction of the administration. Ship’s crew is using the top side #5 starboard tank as a sewage holding tank which has not been approved by class. 74SOLAS(01)II-2/20.. 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to attest to the repairs/ modifications made to the vessel. All was found to be satisfactory and IAW the attending Classification Surveyor''s report.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 August 2015 Resolved
2035: Gerneral arragnements fire plan shall be permanently exhibited for the guidance of the ships officers. showing fire detection and fire extinguishing appliances. Vessels fire control plan does not reflect the correctr number of fire fighting outfits. 74SOLAS(2001)II-2/20. 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 September 2015
Resolution: PSC members attended the vessel at Anchorage #9 SF Bay, CA to attest to the repairs/ modifications made to the vessel. All was found to be satisfactory and IAW the attending Classification Surveyor''s report.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 25 August 2015 Resolved
1510: Navigation systems and equipment shall conform to approptiate performance standards not inferior to those adopted by the orginazation. Vessels AIS is six degrees off. 74SOLAS(14)V/18.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2015
Resolution: Vessl AIS has been fixed and code 17 has been lifted.
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 4 September 2007 Resolved
C/O is using a non-approved ballast water handling log. The recording of sediment has not been done as per plan. Rectify to the satisfaction of the Admin.
Action required: 705 - Other - as specified
Due 4 October 2007
Resolved 19 September 2007
Resolution: Ballast plan was corrected to the satisfaction of Class.
Fire Fighting › Fire Hoses › Condition
Issued 4 September 2007 Resolved
During test of the ship's fire hoses, 8 65mm hoses failed. They had excessive leaks throughout. Replace 8 hoses.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2007
Resolution: Received class report from NKK. Class confirmed the 8pcs of new certified fire hoses were replaced.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 4 September 2007 Resolved
The crew connected their sewage discharge to #5(S)TST without approval by class.
Action required: 705 - Other - as specified
Resolved 4 October 2007
Resolution: Received class report with following statement. The drawing was approved by NK Head Office as of 5 Sept 2007 and verified the modification at this time. Refer to attach the approved drawing.
Documentation › Logs/Records › Oil Record Book
Issued 4 September 2007 Resolved
Oil record book not maintained as per MARPOL requirements. Recordings for weekly collection and disposal of sludge Code"C" 11.1-11.3 is not being done. Transfer of oily waste from bilge wells to bilge hold tank not correctly recorded. Code"D" 13,14&15.3 must be used. Rectify to satisfaction of class and admin.
Action required: 705 - Other - as specified
Due 4 October 2007
Resolved 19 September 2007
Resolution: Ballast plan was corrected to the satisfaction of Class.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 September 2007 Resolved
First aid kit in the engine control room was not ready for use. 95% of equipment was missing/used. ILO-147
Due 4 September 2007
Resolved 4 September 2007
Resolution: Corrected on the spot.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 4 September 2007 Resolved
SOLAS training manual is not ship specific. Items that are specific in nature and directly related to the vessel haven't been added. Rectify to satisfaction of class and admin.
Action required: 705 - Other - as specified
Due 4 October 2007
Resolved 19 September 2007
Resolution: Ballast plan was corrected to the satisfaction of Class.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 September 2007 Resolved
Lifejackets in forward bosun store are blocked by hoses and not readily available. Rectify to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2007
Resolution: Received class report from master to confirm hoses were moved and the area around lifejackets clear.
Lifesaving › Lifebuoys › Immediately Available
Issued 3 September 2007 Resolved
Bridge wing lifebuoys were not ready for immediate use. Buoy/smoke and light would not have deployed due to excessive paint. Rectify to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2007
Resolution: Received class report from master. Confirmed/freed up the cause of stuck paint and available for immediate use.
Lifesaving › Inflatable Liferafts › Float Free
Issued 3 September 2007 Resolved
Float free arrangement for the life rafts is not correct. The present arrangement would cause damage to the raft. Rectify to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2007
Resolution: Received class report from master. Corrected the assembly of the weak link and painter line.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 3 September 2007 Resolved
A bottle of red wine was found in the engine room refrigerator. Recommend a review of the company policy regarding drinking with the crew by the master.
Due 4 September 2007
Resolved 4 September 2007
Resolution: Corrected on the spot.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 3 September 2007 Resolved
Crew not following garbage management plan. Expired medical waste/pyrotechnics are stored in 2nd/3rd officers lockers in boxes, not in red cans as per the SMS Doc. No MK-MN-07-07A. Oily rags found in crew laundry room in black can, not red can as per plan. C/O not using above SMS Doc as primary guidance. Section 5.7 regarding incinerator use while in port should be removed. Rectify w/ admin/class
Action required: 705 - Other - as specified
Due 4 October 2007
Resolved 19 September 2007
Resolution: Ballast plan was corrected to the satisfaction of Class.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 August 2006 Resolved
A boundries fire doors to engine room and stairwell are not self-closing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2007
Resolution: Verified the class report for the deficiency regarding A boundaries fire doors to engine room and stairwell.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 24 August 2006 Resolved
Emergency lighting at the 6-man forward liferaft boat lowing station non-operational.
Condition: Improper/Lack of Maintenance
Due 24 August 2006
Resolved 24 August 2006
Resolution: Changed light bulb.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.