MAURY USCG vessel records
← All vessels

DUBLIN EXPRESS

Built
2002
Last inspected
3 December 2021
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 December 2021
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9232577
606634
Flag
BERMUDA
Maury page id
psix-606634

Documentation record

Tonnage as PSIX records it46009 - Convention (Subpart B), Gross Ton
25880 - Convention (Subpart B), Net Ton
54155 - Dead Weight, Metric Ton
74112 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

3 December 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7361704
30 November 2021 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7361664
29 November 2021 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7358587
12 October 2021 PSC B · MARPOL Annex VI Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7329949
1 April 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7167086
10 March 2021 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7153459
1 March 2020 Damage Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6918608
29 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6917996
26 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6916354
17 January 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6891504
14 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6855344
30 July 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6767489
26 July 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6762751
3 May 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6675878
31 March 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6653150
28 March 2019 Ballast Water Examination · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6651660
28 March 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6651669
11 February 2019 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623578
24 August 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6521593
13 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6371016
29 January 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6345170
23 February 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6093139
15 January 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6071220

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021 Resolved
After any survey of the ship no changes shall be made in structural arrangements machinery, equipment and oher items covered by the survey without sanction of the administration. PSCO observed that the crew placed a portable fan by the #1 SSDG to help with cooling for the control panel to prevent overheating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2021
Resolved 2 December 2021
Resolution: Received class report attesting to fix.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 March 2019 Resolved
Satisfactory means (in the form of guard rails, lifelines, gangways, or underdeck passages, etc) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. Outboard guard rail on port side of bay 22 is missing. Additionally, safety railings on catwalks around cargo hold 6 are damaged. ICLL 66/ Reg 25(4)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 April 2019
Resolved 3 May 2019
Resolution: Main deck handrails have been replaced and repaired with welded pipe(s). Repairs are considered permanent and complete. Class Report Attached in documents.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 January 2018 Resolved
74 SOLAS (01) II-2/ 21 - Fire Extinguishing Appliances shall be kept in good order and available for immediate use at all times. The CO2 release control cabinet located in the CO2 room broke free from its mount and was held in place by CO2 activation lines. Mechanincal condition of CO2 activation system unknown.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 13 March 2018
Resolution: PSC Miami recieved DNV-GL Class survey stating The CO2 system for the E/R was function tested succesfully on 2018-03-12.The newly installed CO2 release cabinet box (original by CO2 system Maker) is acceptable. See attached survey in documents.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 January 2017 Resolved
The ship and its equipment shall be maintained to ensure the ship remains fit to proceed to sea without danger to the ship or persons onboard. Pipe lagging in fuel purifier room is soaked with fuel. 16ac
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 19 January 2017
Resolution: Received class survey attesting to renewed pipe lagging.
Lifesaving › Lifeboat › Hull
Issued 16 January 2017 Resolved
The ship and its equipment shall be maintained to ensure the ship remains fit to proceed to sea without danger to the ship or persons onboard. Port side lifeboat has a hole in the gel coat on the port stern of the boat. 16ac
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 19 January 2017
Resolution: Received class survey report attesting to repair of hole in gel coat of port side lifeboat.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 January 2017 Resolved
Hold back hooks are not permitted on self closing A or B class doors without central control station release. Manual hold back hooks are installed on numerous A and B class doors. 16ac
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 19 January 2017
Resolution: Received class survey report attesting to removal of hold back hooks.

Ownership record