MAURY USCG vessel records Sign in
← All vessels

CHINOOK

CHINOOK is a 2001 tank ship. The Coast Guard has recorded 14 inspections since 2003, most recently in October 2008, along with 4 deficiencies and 3 operational controls.

Records from 2003 to 2008. Most recent: inspection, 5 October 2008.

Built
2001
Last inspected
5 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9037147 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
606734
Flag
MARSHALL ISLANDS
—
Maury page id
psix-606734

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (2003–2008)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it24252 - Convention (Subpart B), Gross Ton
24252 - Simplified, Gross Ton
11704 - Simplified, Net Ton
11704 - Convention (Subpart B), Net Ton
50225 - Displacement, Ton
38782 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

5 October 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3338935
29 September 2008 ISPS II Exam · PII Safety Exam · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3334611
1 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3070568
18 May 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2934238
18 May 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2946579
13 May 2007 ISPS II Exam · COC-TVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2929989
12 May 2007 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2928777
25 February 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2877211
14 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2778285
12 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2776391
9 September 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2773939
19 April 2006 COC-TVE Renew · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2628008
6 July 2004 PII Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2122934
8 January 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1727677

Deficiency record · 4

Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 October 2008 Resolved
Chief engineer had a heart attack and was transported to hospital. Vessel was given permission to move to Port Everglades anchorage to await arrival of new chief engineer. Vessel issued a deficiency to meet minimum safe manning rrequirements prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2008
Lifesaving › Launching Appliances › Winch
Issued 19 April 2006 Resolved
Limit switch for starboard lifeboat operates when tested but does not stop winch motor prior to lifeboat impacting physical stops. Adjust limit switch to stop winch before lifeboat reaches physical stops.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 September 2006
Resolution: Limit switch is working properly
Fire Fighting › Fire Pumps › Arrangement
Issued 8 January 2003 Resolved
No.1 fire pump inoperative.Provide class report to attest satisfactory repair and testing of the pump not later than 10Feb03.
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 6 July 2004
Resolution: Viewed satisfactory this date.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 8 January 2003 Resolved
Various Fuel oil leaks around service tank valves for emergency diesel generator. Provide class report to attest to the satisfactory repair and testing of the EDG Fuel Oil lines.
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 6 July 2004
Resolution: Viewed satisfactory this date.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.