MAURY USCG vessel records Sign in
← All vessels

INNISFAIL

INNISFAIL is a 1939 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1988, most recently in January 2026, along with 121 deficiencies, 1 operational control and 1 casualty investigation in 2022.

Records from 1988 to 2026. Most recent: inspection, 20 January 2026.

Built
1939
Last inspected
20 January 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL5400
Flag
UNITED STATES
367431280
Maury page id
psix-60675

Inspections, by type

…with no type recorded7
Years with a record 36 calendar years (1988–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.1 ft × 18.0 ft × 8.8 ft
Registered tonnagegross 89 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMATHIS YACHT BUILDING CO. · CAMDEN, NJ, UNITED STATES · built 1939
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCAMDEN, NJ
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationCase Pending · issued 12 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL5400MMSI 367431280 · active · compulsorily equipped · granted 9 April 2020, expires 9 April 2030
WDF2733MMSI 367431280 · expired · compulsorily equipped · granted 13 November 2009, cancelled 18 January 2020
WDC7111MMSI 367066330 · expired · compulsorily equipped · granted 10 September 2005, cancelled 14 November 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCS2550MMSI not assigned · expired · voluntarily equipped · granted 7 September 1995, cancelled 13 August 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

20 January 2026 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8298723
22 April 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8091696
18 March 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7880878
8 January 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7845517
17 May 2023 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7690786
17 March 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7652411
13 June 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7476147
10 June 2022 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7474413
23 May 2022 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7452204
14 March 2021 Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7155839
28 August 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7043871
13 April 2020 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6935195
25 July 2019 Administrative Inspection · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6755251
13 June 2019 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6712465
9 April 2019 Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6658654
20 June 2018 Excursion Permit · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6450430
18 June 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6441407
11 October 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6285578
12 January 2017 Drydock Exam · Annual Inspection · Deficiency Check · DAPI Audit · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6072313
13 December 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6057219
28 June 2016 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5922638
18 November 2015 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5766050
4 September 2015 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5234826
25 January 2012 Inclining Experiment
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4231969
1 September 2011 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4132859
4 January 2011 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3919711
30 November 2010 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3900977
9 March 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3430578
21 April 2008 Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3188715
4 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3158229
16 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3080911
18 April 2007 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2910259
11 October 2006 Drydock Extension
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2799010
12 September 2006 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2775870
13 December 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2550875
25 October 2005 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2522033
25 August 2005 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2474187
24 November 2004 Hull Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2247311
20 October 2004 Periodic Inspection · Administrative Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2220021
6 October 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1905366
19 September 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1673486
6 September 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1366557
16 October 2000 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1417142
13 September 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1454852
28 April 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1047364
5 November 1999 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1437629
13 September 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1120244
12 August 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1456727
19 April 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 789386
15 October 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1408193
31 July 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1388349
30 October 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1164851
20 August 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1407738
11 June 1996 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360340
11 September 1995 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1185152
11 September 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1193514
1 September 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1390113
8 May 1995 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1044768
8 September 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173333
18 March 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1326437
16 February 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1163374
24 September 1993 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1163055
8 September 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 848276
8 September 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1359446
22 August 1992 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1262631
30 July 1992 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 962085
29 April 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134358
17 December 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 953367
19 November 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252885
3 October 1991 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1462290
23 July 1991 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441947
2 May 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 899293
2 March 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1029091

Deficiency record · 121

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Replace expired contents of first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 30 April 2025
Resolution: New med kit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2025 Resolved
Chemical testing equipment expired. Provide satisfactory drug and alcohol screening procedures. replace expired alcohol screening kits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 30 April 2025
Resolution: Received new alocohol test swabs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2025 Resolved
A vessel must comply with the applicable Federal Communications Commission requirements for any radio installation. Obtain radio safety certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 30 April 2025
Resolution: received new certs from radio hollad.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2023 Resolved
Each life buoy on a vessel must be approved in accordance with 46 CFR 160.050 in subchapter Q; must have a breaking strength of at least 5 kilonewtons (1,124 pounds). Line on buoy was found frayed and broke upon pull test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 17 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Missing labeling for child life jackets on aft storage door.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 17 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2020 Resolved
Non-rechargable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel missing 2 tags and 1 expired. Have extinguishers serviced. Aft stateroom, crew lounge and engine room.
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 15 April 2020
Resolution: Vessel provided documentation of annual servicing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2020 Resolved
The frame or support of each semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead. Forward crew stateroom and guest quarters bottom of stairs, mount brackets.
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 15 April 2020
Resolution: Brackets mounted for both fire extinguishers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2020 Resolved
Flexible tubing may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump. Discharge line of forward deck overboard discharge is leaking.
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 15 April 2020
Resolution: Both flexible hose clamps at thru-hull fitting were tightened to stop the leak.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 13 April 2020 Resolved
A vessel with installed toilet facilities must have a marine sanitation device. Holding tank has a hole in the top corner and is also leaking at the overboard discharge into the bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 3 November 2020
Resolution: New MSD installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2020 Resolved
A vessel must comply with the applicable requirement for any radio installation including the requirement for a station license and installation certificate. Update call sign on FCC safety license and Bridge to Bridge certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 28 August 2020
Resolution: Call Sign corrected on FCC Licenses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2019 Resolved
Vessels remote fuel shut off valve did not indicating purpose of the valve as described in 46CFR185.608. Provide a means of indicating purpose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2019 Resolved
Engine room ventilation closure for starboard duct was not working as described in 46CFR182.465(h). Repair closure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2019 Resolved
Vessel has a fresh water pipe leak through a watertight bulkhead that needs to be repaired. Ensure that the repair complies with Penetrations of required watertight decks and bulkheads by any rigid plastic pipe as described by 46CFR182.720(d).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2019 Resolved
Vessels bilge piping system in the forward bilge was corroded and needed to be replaced as described in 46CFR 182.510. Replace piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC junction box for electrical submersible pump exposed in the forward bilge and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must install a face plate or remove the outlet and all associated wiring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 April 2019 Resolved
Vessels starboard side outboard shaft bearing support has wood decay and does not meet the structural design requirements as described in 46CFR177.300. Provide a repair proposal for review and approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC dead end wires in the center of the bilge aft engine room and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must remove wire from the source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC dead end wires above port side muffler engine room and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must remove wire from the source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 9 April 2019 Resolved
Vessel has excessive accumulation of oil in the engine room bilges and must be removed as required by 46CFR176.830(b). Remove oil from Bilges
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC dead end wires in the Lazaret starboard side above high level alarm and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must remove wire from the source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 June 2018 Resolved
11117 - Replace expired life ring light battery prior to operating at night 705(c)
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Master provided image of new battery installed.
Engineering › Bilge Water Management System › Not Operational
Issued 18 June 2018 Resolved
04113 - Prove proper operation of bilge high level alarm in lazarette - 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2018
Resolution: Master provided video of proper operation of bilge high level alarm.
Engineering › Bilge Water Management System › Not Installed
Issued 18 June 2018 Resolved
04113 - Properly mount bilge pump float switch in lazarette - 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2018
Resolution: Master provided image of properly mounted bilge pump float switch.
Lifesaving › Hand Flares › Quantity
Issued 18 June 2018 Resolved
10124 - Provide a total of 6 red flares and 6 orange smokes prior to operating on a coastwise or oceans route. 705(c)
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Master provided proof of newly purchased flares.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 June 2018 Resolved
10116 - Provide coast pilot for excursion permit route prior to operating north of Virginia. 705(c)
Action required: 705 - Other - as specified
Resolved 20 June 2018
Resolution: Master provided evidence of electronic Coast Pilots onboard for entire excursion permit route.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 June 2018 Resolved
09112 - Replace expired first aid kit components. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of newly purchased first aid kit approved by 160.041.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 June 2018 Resolved
07114 - Prove proper operation of STBD engine room air intake remote closure. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of proper operation.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 June 2018 Resolved
11199 - Replace kinked life ring line. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of new life ring line.
Fire Fighting › Firemans Outfit › Axe
Issued 18 June 2018 Resolved
07199 - Mount fire axe in vicinity of operating station. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of fire axe mounted.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 June 2018 Resolved
04103 - Mount portable light in vicinity of engine room entrance. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 25 June 2018
Resolution: Master mounted portable light outside of engine room.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 June 2018 Resolved
07106 - Replace modular smoke detector in galley. Detector must meet UL217 rating. 46 CFR 181.405(c). 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 25 June 2018
Resolution: Master replaced smoke detector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2018 Resolved
09209 - Review heat shrink and secure cover on security system box in crew space locker. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 25 June 2018
Resolution: Master proved repairs were made.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 June 2018 Resolved
01350 - Passenger count is not being reported ashore. Provide means to record passenger count ashore. 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2019
Resolution: 185.504 Passenger count: Vessel keeps a correct, written count of all passengers that embark on and disembark from the vessel in writing, in a mailbox at its primary mooring location and available ashore at the vessel’s normal berthing location. The pa
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2018 Resolved
04109 - Provide documentation that monthly drills are being conducted. 10(c)
Action required: 10 - Deficiency Rectified
Due 18 June 2018
Resolved 18 June 2018
Resolution: Master will begin documenting monthly drills.
Fire Fighting › Nozzles › Approval
Issued 18 June 2018 Resolved
07110 - Provide fire hose nozzles meeting type approval series 162.027. 16(c). Nozzles to be provided as soon as practicable after arriving in Nantucket.
Action required: 705 - Other - as specified
Resolved 1 July 2018
Resolution: Master proved installation of correct firefighting nozzle.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 July 2017 Resolved
COD expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 1 August 2017
Resolution: COD was paid for and will recieve in two to three weeks, for hard copy.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 July 2017 Resolved
Alcohol testing strips were expired.
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 1 August 2017
Resolution: New alcohol strips were found onboard.
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 2 March 2011 Resolved
Provide proof to USCG that the vessel's ballast is IAW stability letter. Once ballast is in required location provide ballast plan to USCG. See copy of deficiency letter in vessel documents
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2011
Resolved 21 April 2015
Resolution: See new stability letter issued 24 October 12.
Construction/Loadline › Hull › Hull Plating
Issued 4 January 2011 Resolved
Make repairs to exterior hull as identified by USCG and vessel rep IAW NVIC 7-95.
Due 10 January 2011
Resolved 14 February 2011
Construction/Loadline › Hull › Transverse Frame
Issued 4 January 2011 Resolved
Make repairs to cracked frame port side in lazarette.
Due 10 January 2011
Resolved 3 February 2011
Electrical › Electric Generation Source (service) › Conductor
Issued 4 January 2011 Resolved
Remove dead-end cable under rack in master stateroom in way of port centerline.
Due 10 January 2011
Resolved 3 February 2011
Engineering › Bilge Water Management System › Pump
Issued 4 January 2011 Resolved
Remove water from bilge in all spaces.
Due 10 January 2011
Resolved 3 February 2011
Stability › Watertight Integrity › General
Issued 4 January 2011 Resolved
Show proper operation of through hull ball valve in master stateroom.
Due 10 January 2011
Resolved 10 January 2011
Stability › Watertight Integrity › General
Issued 4 January 2011 Resolved
Provide dogs on stbd port light in master stateroom under stairs.
Due 10 January 2011
Resolved 14 February 2011
Stability › Watertight Integrity › General
Issued 4 January 2011 Resolved
Reposition raw water a/c valve in engine room to allow the handle to close all the way.
Due 10 January 2011
Resolved 3 February 2011
Stability › Watertight Integrity › General
Issued 4 January 2011 Resolved
Show operation of through hull valve stbd side in crew cabin space.
Due 10 January 2011
Resolved 10 January 2011
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 4 January 2011 Resolved
Provide proof to USCG of accounted for ballast IAW the vessel's stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Construction/Loadline › Markings › Load Line Mark
Issued 4 January 2011 Resolved
Provide draft markings or permanent loading marks IAW 46CFR185.30-3 and the vessel's stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 November 2010 Resolved
Provide valid Certificate of Documentation with a Coastwise Endorsement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2010
Resolved 10 January 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 November 2010 Resolved
Provide valid Bridge to Bridge and FCC Safety Radio certificates.
Due 11 December 2010
Resolved 10 January 2011
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 November 2010 Resolved
Provide current and corrected copies of Light List and US Coast Pilot.
Due 11 December 2010
Resolved 10 January 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 30 November 2010 Resolved
Provide portable fire extinguishers as required by 46 CFR 181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2010
Resolved 10 January 2011
Construction/Loadline › Hull › Transverse Frame
Issued 27 October 2006 Resolved
Perform permanent repairs to two adjacent transverse floor frames, aft, below stateroom, iwo forward struts, where severely rotted around fasteners.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 8 May 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 11 October 2006 Resolved
Mechanically plug or remove unused through-hull valve, port side fwd, beneath crews quarters.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 4 May 2007
Construction/Loadline › Hull › Bottom Plating
Issued 11 October 2006 Resolved
Determine cause of weeping iwo butt-blocks as marked beneath tool space, iwo wash machine and refrigerator, and beneath liquor stowage closet in master stateroom.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 14 May 2007
Construction/Loadline › Hull › Stringer
Issued 11 October 2006 Resolved
Permanently repair localized rot iwo forward, lower inboard engine beds, port and starboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 7 May 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 October 2006 Resolved
Permanently repair lower bilge clamp where rotted iwo starboard generator, main engine space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 7 May 2007
Electrical › Electric Supply System (service) › Cable
Issued 12 September 2006 Resolved
Secure circuit breaker and permanently connect wiring in approved manner to aft watercloset transformer. Currently breaker is hanging loose on deck and wiring is connected via splice and electric tape.
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 12 October 2006
Resolution: breaker secured to bulkhead via brace and crimp fitting used in wiring- digital pic of repair sent to inspector
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 September 2006 Resolved
Secure CO2 cylinders (charging system for soft drink dispenser) in aft stateroom, starboard closet. Cylinders currently standing in upright condition and readily moveable. Temporarily layed down and wedged in place.
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 13 September 2006
Resolution: Cradles/permanent tie-downs installed.
Stability › Watertight Integrity › General
Issued 12 September 2006 Resolved
Replace glass in fractured port lights, starboard side, master stateroom head and liquor closet.
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 4 May 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 12 September 2006 Resolved
Replace existing intake/exhaust ventillation ducts (natural) with ones made from fire proof material. Current vent ducts are made from PVC.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 4 May 2007
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 25 October 2005 Resolved
Repair or replace GFI outlet in galley. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2005 Resolved
Provide updated first aid kit in accordance with 46 CFR 184.710
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 25 October 2005 Resolved
Repair or replace stair light leading to aft lower cabin. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 25 October 2005 Resolved
Place donning placard for childs KAPOK lifejacket or replace with similar adult life jackets. 46 CFR 185.516
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 25 October 2005 Resolved
Replace retro reflective tape on child lifejackets or replace 46 CFR 185.604
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 October 2005 Resolved
Provide proof of proper first aid training and documentation. NVIC 1-91
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2005 Resolved
Provide proof of proper servicing of vessels oxygen bottles. 46 CFR 184.710
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 2 December 2005
Stability › Watertight Integrity › General
Issued 25 August 2005 Resolved
Provide onboard a correct stability letter which addresses the location of the watertight door and the removable watertight bulkhead at aft stateroom.
Due 31 January 2006
Resolved 30 May 2006
Stability › Watertight Integrity › General
Issued 6 December 2004 Resolved
Provide onboard a correct stability letter which addresses the location of the watertight door and the removable watertight bulkhead at aft stateroom.
Due 6 January 2005
Resolved 5 October 2005
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 24 November 2004 Resolved
Renew starboard generator fuel line where temporary splice installed.
Due 24 December 2004
Resolved 6 December 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 24 November 2004 Resolved
All non-metallic piping penatrations watertight bulkheads must be installed in accordance with 46 CFR 182.720 (d)
Due 24 December 2004
Resolved 6 December 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 24 November 2004 Resolved
All openings in watertight bulkheads must be made watertight in accordance with 46 CFR 179.320
Due 24 December 2004
Resolved 6 December 2004
Engineering › Bilge Water Management System › Not Operational
Issued 24 November 2004 Resolved
Prior to carriage of passengers prove proper operation of fixed bilge system form each compartment served.
Due 24 December 2004
Resolved 6 December 2004
Stability › Watertight Integrity › General
Issued 24 November 2004 Resolved
Provide current stability letter indicating currently installed main transverse watertight bulkheads.
Due 24 December 2004
Resolved 6 December 2004
Documentation › Markings/Placards › Warning Signs
Issued 24 November 2004 Resolved
Mark emergency escape hatches in accordance with 46 CFR 185.606
Due 24 December 2004
Resolved 6 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2004 Resolved
Obtain or outfit first aid kit IAW 46 CFR 187.710 and 160.41
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 6 December 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 October 2004 Resolved
Repair loose receptacle and cover main deck ladder well starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 October 2004 Resolved
Remove all plastic waste receptacles and replace with non-combustible type IAW 46 CFR 177.405f
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 20 October 2004 Resolved
Remove all outlet multipliers in receptacles in aft and forward crew berthing and in main deck TV cabinet, or submit plans to modify circuits to handle additional loads
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Stability › Watertight Integrity › General
Issued 20 October 2004 Resolved
Properly mark WTD in engine room as required by 46 CFR 185.610.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Blower, Centrifugal
Issued 20 October 2004 Resolved
Provide double nuts or lock nuts for Air box damper. Remove pull cable (Morse cable) at both main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2004 Resolved
Ensure all wire runs are secured by metal fasteners every 24 inches IAW IEEE 45-20.5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2004 Resolved
Remove dead end wires in TV console cabinet or properly terminate in junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 24 November 2004
Documentation › Logs/Records › MIS Form
Issued 20 October 2004 Resolved
Provide proof of MIS report in IAW 46 CFR 16.500
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 6 December 2004
Engineering › Thrusters › Pump
Issued 20 October 2004 Resolved
Prove proper operation of bow thruster hydraulic pump clutch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2004
Resolved 6 December 2004
Construction/Loadline
Issued 12 August 1999 Resolved
Install caps on four 3/4" pipes penetrating engine room bulkheads.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Electrical
Issued 12 August 1999 Resolved
Install metallic wiring supports throughout vessel.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Documentation
Issued 12 August 1999 Resolved
Provide up to date stability letter. Existing letter does not address lead pigs being used as ballast.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Engineering
Issued 12 August 1999 Resolved
Provide screen with 30 x 30 mesh in fuel tank vent.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Electrical
Issued 20 August 1996 Resolved
Install cover on junction box located in lazarette.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Electrical
Issued 20 August 1996 Resolved
Cover openings on front of main switch board.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Documentation
Issued 20 August 1996 Resolved
Provide current FCC Great Lakes Agreement certificate.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Navigation
Issued 20 August 1996 Resolved
Provide a current copy of the NAVRULES.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Electrical
Issued 20 August 1996 Resolved
Install blanks in breaker panel located at bottom of aft stairway.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Construction/Loadline
Issued 1 September 1995 Resolved
Replace gasket to watertight door.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Electrical
Issued 1 September 1995 Resolved
Replace wiring on main engine solenoid shutdowns that has cracked sheathing; renew with marine type wiring.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Engineering
Issued 1 September 1995 Resolved
Provide adequate closure system for engine room air intakes.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 1 September 1995 Resolved
Provide one Category II/406 Mhz EPIRB for Great Lakes route in accordance_x001C_ with 46 CFR 180.40-1(c).
Condition: Unknown
Due 5 September 1995
Resolved 8 September 1995
Construction/Loadline
Issued 1 September 1995 Resolved
Replace in-kind frame on PORT side in way of keel two frames forward of tailshaft head log.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Navigation
Issued 1 September 1995 Resolved
Provide documentation that verifies non-fired pressure vessel meets ASME marine standards or replace with pressure vessel that does meet ASME marinestandards.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Construction/Loadline
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO THE MAIN ENGINE DRIVEN JABSCO FIRE PUMPS. (VESSEL NEEDS ONE MORE FIXED POWER PUMP)
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Lifesaving
Issued 8 September 1993 Resolved
CLEAN ALL OIL FROM THE VESSEL BILGES.
Condition: Unknown
Due 29 September 1993
Resolved 2 February 1994
Engineering
Issued 8 September 1993 Resolved
MAKE THE VESSEL'S FUEL OIL TANK VENTS AND FLAMESCREENS ACCESSIBLE FOR VISUAL INSPECTION.
Condition: Unknown
Due 29 September 1993
Resolved 2 February 1994
Construction/Loadline
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PLACE ON BOARD AN APPROPRIATE HOSE FOR THE HAND BILGE PUMP TO ALLOW ITS USE FROM THE MAIN DECK.
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Lifesaving
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW THE TWO LIFERING LINES.
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Engineering
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO THE STARBOARD MAIN DIESEL ENGINE FUEL PUMP.
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Navigation
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PLACE ON BOARD A CURRENT CHART OF THE AREA.
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Lifesaving
Issued 8 September 1993 Resolved
IMPLEMENT THE DRUG TESTING PROGRAM AS REQUIRED BY 46 CFR PARTS 4 AND 16.
Condition: Unknown
Due 29 September 1993
Resolved 2 February 1994
Lifesaving
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, REPAIR THE RETRO-REFLECTIVE TAPE ON ONE CHILDS PFD TO MAKE A TOTAL OF EIGHT.
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Fire Fighting
Issued 8 September 1993 Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO THE ENGINE ROOM HALON SYSTEM INDICATOR LIGHT WHICH IS MOUNTED IN THE PILOT HOUSE.
Condition: Unknown
Due 15 September 1993
Resolved 2 February 1994
Electrical
Issued 8 September 1992 Resolved
Demonstrate operation of port side generator.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Unknown
Issued 19 November 1991 Resolved
COMPLETE THE REMAINING ITEMS ON THE WORKLIST DTD 14NOV91, ITEMS NO'S 7,8,9, 10,13,17,AND 21.
Condition: Unknown
Due 13 December 1991
Resolved 8 January 1992
Lifesaving
Issued 3 October 1991 Resolved
PROVIDE MARKING FOR PFD STOWAGE BELOW DECKS
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Lifesaving
Issued 3 October 1991 Resolved
PROVIDE MARKING FOR NUMBER OF PERSONS ALLOWED FOR BOUYANT APPARATUS.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Construction/Loadline
Issued 3 October 1991 Resolved
MAKE REPAIRS TO VARIOUS PORT LIGHTS IN THE SIDE SHELL TO ELIMINATE LEAKAGE.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Lifesaving
Issued 3 October 1991 Resolved
PROVIDE MARKING FOR PADDLES ON BOUYANT APPARATUS
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Construction/Loadline
Issued 3 October 1991 Resolved
COMPLETE AFT WATERTIGHT BULKHEAD FORWARD OF AFT CABIN TO KEEL.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Construction/Loadline
Issued 3 October 1991 Resolved
REPAIR CRACKED FRAME IN BILGE AREA, CREWS QUARTERS, STARBOARD SIDE.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Construction/Loadline
Issued 3 October 1991 Resolved
MAKE PROPER REPAIRS TO FRAMES ON STARBOARD SIDE AFT. FRAMES HAD PREVIOUSLY BEEN REPAIRED IMPROPERLY.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Construction/Loadline
Issued 3 October 1991 Resolved
REPAIR BUTT BLOCK BETWEEN FRAMES 5 AND 6 AFT FROM WATERTIGHT BULKHEAD ON THE STARBOARD SIDE CREWS QUARTERS.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991

Casualty record · 1

13 June 2022Routine · role: Involved in a Marine Casualty · at CSX ORTEGA RIVER RAILROAD BRIDGE · activity 7476147
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.