MAURY USCG vessel records
← All vessels

INNISFAIL

INNISFAIL is a 1939 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in January 2026, along with 37 deficiencies, 1 operational control and 1 casualty investigation in 2022.

Records from 2016 to 2026. Most recent: inspection, 20 January 2026.

Built
1939
Last inspected
20 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL5400
Flag
UNITED STATES
Maury page id
psix-60675

Documentation record

Registered dimensions (L × B × D)80.1 ft × 18.0 ft × 8.8 ft
Registered tonnagegross 89 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMATHIS YACHT BUILDING CO. · CAMDEN, NJ, UNITED STATES · built 1939
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCAMDEN, NJ
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 12 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

20 January 2026 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8298723
22 April 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8091696
18 March 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7880878
8 January 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7845517
17 May 2023 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7690786
17 March 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7652411
13 June 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7476147
10 June 2022 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7474413
23 May 2022 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7452204
14 March 2021 Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7155839
28 August 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7043871
13 April 2020 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6935195
25 July 2019 Administrative Inspection · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6755251
13 June 2019 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6712465
9 April 2019 Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6658654
20 June 2018 Excursion Permit · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6450430
18 June 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6441407
11 October 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6285578
12 January 2017 Drydock Exam · Annual Inspection · Deficiency Check · DAPI Audit · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6072313
13 December 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6057219
28 June 2016 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5922638

Deficiency record · 37

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Replace expired contents of first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 30 April 2025
Resolution: New med kit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2025 Resolved
Chemical testing equipment expired. Provide satisfactory drug and alcohol screening procedures. replace expired alcohol screening kits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 30 April 2025
Resolution: Received new alocohol test swabs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2025 Resolved
A vessel must comply with the applicable Federal Communications Commission requirements for any radio installation. Obtain radio safety certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 30 April 2025
Resolution: received new certs from radio hollad.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2023 Resolved
Each life buoy on a vessel must be approved in accordance with 46 CFR 160.050 in subchapter Q; must have a breaking strength of at least 5 kilonewtons (1,124 pounds). Line on buoy was found frayed and broke upon pull test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 17 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Missing labeling for child life jackets on aft storage door.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 17 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2020 Resolved
Non-rechargable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel missing 2 tags and 1 expired. Have extinguishers serviced. Aft stateroom, crew lounge and engine room.
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 15 April 2020
Resolution: Vessel provided documentation of annual servicing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2020 Resolved
The frame or support of each semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead. Forward crew stateroom and guest quarters bottom of stairs, mount brackets.
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 15 April 2020
Resolution: Brackets mounted for both fire extinguishers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2020 Resolved
Flexible tubing may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump. Discharge line of forward deck overboard discharge is leaking.
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 15 April 2020
Resolution: Both flexible hose clamps at thru-hull fitting were tightened to stop the leak.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 13 April 2020 Resolved
A vessel with installed toilet facilities must have a marine sanitation device. Holding tank has a hole in the top corner and is also leaking at the overboard discharge into the bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 3 November 2020
Resolution: New MSD installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2020 Resolved
A vessel must comply with the applicable requirement for any radio installation including the requirement for a station license and installation certificate. Update call sign on FCC safety license and Bridge to Bridge certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2020
Resolved 28 August 2020
Resolution: Call Sign corrected on FCC Licenses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2019 Resolved
Vessels remote fuel shut off valve did not indicating purpose of the valve as described in 46CFR185.608. Provide a means of indicating purpose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2019 Resolved
Engine room ventilation closure for starboard duct was not working as described in 46CFR182.465(h). Repair closure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2019 Resolved
Vessel has a fresh water pipe leak through a watertight bulkhead that needs to be repaired. Ensure that the repair complies with Penetrations of required watertight decks and bulkheads by any rigid plastic pipe as described by 46CFR182.720(d).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2019 Resolved
Vessels bilge piping system in the forward bilge was corroded and needed to be replaced as described in 46CFR 182.510. Replace piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC junction box for electrical submersible pump exposed in the forward bilge and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must install a face plate or remove the outlet and all associated wiring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 April 2019 Resolved
Vessels starboard side outboard shaft bearing support has wood decay and does not meet the structural design requirements as described in 46CFR177.300. Provide a repair proposal for review and approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC dead end wires in the center of the bilge aft engine room and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must remove wire from the source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC dead end wires above port side muffler engine room and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must remove wire from the source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 9 April 2019 Resolved
Vessel has excessive accumulation of oil in the engine room bilges and must be removed as required by 46CFR176.830(b). Remove oil from Bilges
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2019 Resolved
Vessel has DC dead end wires in the Lazaret starboard side above high level alarm and does not meet minimum standard of electrical installations being reasonably safe from shock of personnel as required by 46CFR183.01-5(a). Owner must remove wire from the source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Sat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 June 2018 Resolved
11117 - Replace expired life ring light battery prior to operating at night 705(c)
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Master provided image of new battery installed.
Engineering › Bilge Water Management System › Not Operational
Issued 18 June 2018 Resolved
04113 - Prove proper operation of bilge high level alarm in lazarette - 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2018
Resolution: Master provided video of proper operation of bilge high level alarm.
Engineering › Bilge Water Management System › Not Installed
Issued 18 June 2018 Resolved
04113 - Properly mount bilge pump float switch in lazarette - 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2018
Resolution: Master provided image of properly mounted bilge pump float switch.
Lifesaving › Hand Flares › Quantity
Issued 18 June 2018 Resolved
10124 - Provide a total of 6 red flares and 6 orange smokes prior to operating on a coastwise or oceans route. 705(c)
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Master provided proof of newly purchased flares.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 June 2018 Resolved
10116 - Provide coast pilot for excursion permit route prior to operating north of Virginia. 705(c)
Action required: 705 - Other - as specified
Resolved 20 June 2018
Resolution: Master provided evidence of electronic Coast Pilots onboard for entire excursion permit route.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 June 2018 Resolved
09112 - Replace expired first aid kit components. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of newly purchased first aid kit approved by 160.041.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 June 2018 Resolved
07114 - Prove proper operation of STBD engine room air intake remote closure. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of proper operation.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 June 2018 Resolved
11199 - Replace kinked life ring line. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of new life ring line.
Fire Fighting › Firemans Outfit › Axe
Issued 18 June 2018 Resolved
07199 - Mount fire axe in vicinity of operating station. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 19 June 2018
Resolution: Master provided proof of fire axe mounted.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 June 2018 Resolved
04103 - Mount portable light in vicinity of engine room entrance. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 25 June 2018
Resolution: Master mounted portable light outside of engine room.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 June 2018 Resolved
07106 - Replace modular smoke detector in galley. Detector must meet UL217 rating. 46 CFR 181.405(c). 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 25 June 2018
Resolution: Master replaced smoke detector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2018 Resolved
09209 - Review heat shrink and secure cover on security system box in crew space locker. 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 25 June 2018
Resolution: Master proved repairs were made.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 June 2018 Resolved
01350 - Passenger count is not being reported ashore. Provide means to record passenger count ashore. 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2019
Resolution: 185.504 Passenger count: Vessel keeps a correct, written count of all passengers that embark on and disembark from the vessel in writing, in a mailbox at its primary mooring location and available ashore at the vessel’s normal berthing location. The pa
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2018 Resolved
04109 - Provide documentation that monthly drills are being conducted. 10(c)
Action required: 10 - Deficiency Rectified
Due 18 June 2018
Resolved 18 June 2018
Resolution: Master will begin documenting monthly drills.
Fire Fighting › Nozzles › Approval
Issued 18 June 2018 Resolved
07110 - Provide fire hose nozzles meeting type approval series 162.027. 16(c). Nozzles to be provided as soon as practicable after arriving in Nantucket.
Action required: 705 - Other - as specified
Resolved 1 July 2018
Resolution: Master proved installation of correct firefighting nozzle.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 July 2017 Resolved
COD expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 1 August 2017
Resolution: COD was paid for and will recieve in two to three weeks, for hard copy.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 July 2017 Resolved
Alcohol testing strips were expired.
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 1 August 2017
Resolution: New alcohol strips were found onboard.

Casualty record · 1

13 June 2022Routine · role: Involved in a Marine Casualty · activity 7476147
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record