PATTAROZZI TIDE is a 2003 offshore supply vessel. The Coast Guard has recorded 14 inspections since 2003, most recently in October 2020, along with 20 deficiencies and 1 operational control.
Records from 2003 to 2020. Most recent: inspection, 16 October 2020.
- Built
- 2003
- Last inspected
- 16 October 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1137027
9289661 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBEG
606928
Flag
VANUATU
369235000 (licence lapsed)
Maury page id
psix-606928
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2003–2020)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it1888 - Convention (Subpart B), Gross Ton
566 - Convention (Subpart B), Net Ton
566 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WBEGMMSI 369235000 · cancelled · compulsorily equipped · granted 21 January 2003, cancelled 22 August 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 14
16 October 2020
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7077372
4 October 2017
COE-Dockside · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6272508
4 October 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6281793
9 May 2007
Annual Inspection
Physical examination · Activities Europe · Activity 2895772
8 February 2006
Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2577542
13 May 2005
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2356719
9 May 2005
Administrative Inspection · MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2352977
24 March 2004
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2035311
10 March 2004
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2021861
20 February 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2009971
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971479
30 September 2003
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1917278
12 September 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1903643
10 March 2003
MARPOL Annex I Examination · Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1744285
Deficiency record · 20
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 October 2017
Resolved
The vessels safety management system shall be maintained in accordiance with the provision of International Safety Management Code. Vessel did not maintain safety management system by not properly maintaining required documentation.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 4 October 2017
Resolved
The master, owner, operator,agent, or person in charge of vessel equipped with ballast tanks that operated in waters in the United States shall employ one of the approved ballast management methods. The vessel did not meet any of the approved ballast management methods.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 4 October 2017
Resolved
Vessel must report the required information at least 24 hours prior to arrival to the National Ballast Information Clearinghouse. Vessel did not report any required information to the National Ballast Information Clearinghouse.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 4 October 2017
Resolved
While operating within the emission control area, the sulfur content of fuel oil on board a vessel shall not exceed 0.10% m/m. The vessel was unable to provide documentation that the fuel oil on board contained less than 0.10% sulfur content. MARPOL ANNEX VI is not listed under a drop down so I chose the option the was most closely related
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 October 2017
Resolved
Oil filtering equipment shall be a design approved by Administration and shall ensure that any oily mixture discharged into sea through a oil content not exceeding 15 ppm. Vessel could not provide evidence or demonstrate that the oily water separator operated.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 October 2017
Resolved
Doors in fire resisting divisions in cargo ships are required to be self closing and shall not be fitted hold-backs on doors. Vessels engine room doors did not self close and had rope hold-backs on engine room doors.
Electrical › Lighting (service) › Lighting Feeder
Issued 4 October 2017
Resolved
Vessels electrical installations shall be such that the safety of the passengers, crew, and ship from electrical hazards will be ensured. Vessel had extension cords connected to main electrical panel and loose electrical connections in the lighting in escape hatch inside engine room. 74 SOLAS(09) II-1/40
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 4 October 2017
Resolved
Fixed fire detection and alarm system installations shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. Vessel had broken inoperable heat detectors in engine room.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 4 October 2017
Resolved
The master,owner, operator, agent, or person in charge or a vessel bound for a port or place in the United States must ensure maintenance of written records that include all the required information. Vessel did not have written documents.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 4 October 2017
Resolved
Any vessel over 300 GT must have fixed containment or a enclosed deck area under or around each fuel oil or bulk lubricating vent. Vessel did not have suitable containment around each fuel oil or lubricating vent.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 9 May 2007
Resolved
Vessel to show proof of a SOLAS Radio Safety Certificate.
Electrical › Electric Supply System (service)
Issued 30 September 2003
Resolved
Prove proper operation of breaker P-403 in loadshedding, as described in approved automation test procedures.
Electrical
Issued 30 September 2003
Resolved
Prove proper operation of power failure alarm for Engine Order Telegraph as required by 46 CFR 113.35-5 (e) (1) and descibed in approved automation test procedure.
Electrical › Electric Generation Source (service)
Issued 30 September 2003
Resolved
Prove proper operation of KW meter, ground fault dector indicator light and generator open breaker indicator light on #3 switchboard as required by 46 CFR 111.30-25.
Electrical
Issued 30 September 2003
Resolved
Prove proper operation of Engine Order Telegraph in engineroom alarms when orders are received from pilothouse in accordance with 46 CFR 113.35-5 (c).
Engineering › Thrusters
Issued 30 September 2003
Resolved
Prove proper operation of bow thruster low lube oil alarm and shutdown as per 46 CFR 61.40-10 and the approved automation test procedures.
Fire Fighting › Fixed Fire Detection System
Issued 30 September 2003
Resolved
Prove bowthruster and tank farm (main machinery space) fire and smoke detectors are on seperate loops as required by SOLAS 74 II-2/13.1.10.
Operations/Management › Equipment Service/Testing
Issued 10 March 2003
Resolved
Provide for review a procedure for tests to be conducted on automated equipment by the operator and the Coast Guard to comply with 46 CFR 127.110 of Subchapter "L" as required by 46 CFR 130.480. LEGACY COMPONENT DESC: Automated Test Procedures
Operations/Management › Equipment Service/Testing
Issued 10 March 2003
Resolved
Provide for review a detailed operations manual that describes the operation and indicates the location of each system installed to comply with 46 CFR Subchapter "L" Part 130 as required by 46 CFR 130.480(e). LEGACY COMPONENT DESC: Operations Manual
Operations/Management › Equipment Service/Testing
Issued 10 March 2003
Resolved
As required by 46 CFR 127.110(f), where automated systems are provided to replace specific personnel in control and observation of the propulsion systems and machinery spaces, plans shall be submitted to the CG Marine Safety Center to demonstrate compliance with 46 CFR Part 130, Subpart "D". LEGACY COMPONENT DESC: Plans
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.