MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 29

STRETCH DUCK 29 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2003, most recently in May 2017, along with 14 deficiencies.

Records from 2003 to 2017. Most recent: inspection, 10 May 2017.

Built
1945
Last inspected
10 May 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF7395
607111
Flag
UNITED STATES
—
Maury page id
psix-607111

Inspections, by type

Years with a record 9 calendar years (2003–2017)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

10 May 2017 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6142913
7 June 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5900144
14 May 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4850917
20 February 2009 COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3421116
27 May 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3218625
14 November 2007 Hull Examination · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3108527
26 March 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2900132
2 March 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2594462
23 February 2005 Simplified Stability Test
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2297790
21 February 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2296455
3 December 2003 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1958340
13 May 2003 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1791502
7 May 2003 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1769768
27 January 2003 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1730395

Deficiency record · 14

Documentation › Logs/Records › Drug Test Records
Issued 20 February 2009 Resolved
Provide copy of drug consortium enrollment of company Captains.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Resolution: Copy of drug consortium enrollment provided.
Engineering › Steering Gear System › Rudder
Issued 20 February 2009 Resolved
Multiple cracks found in rudder requiring replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Resolution: Cracks in rudder were repaired by grinding out the cracks and rewelding.
Engineering › Gasoline Engine (propulsion) › Carburetor (4 cycle)
Issued 20 February 2009 Resolved
Engine was backfiring the entire trip back to the garage. Timing needs to be advanced or the carb leaned out.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Resolution: Company Mechanic serviced engine on the vehicle.
Construction/Loadline › Hull › Hull Plating
Issued 14 November 2007 Resolved
Crop and renew wasted area on forward end of vessel as marked and discussed.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2007
Resolution: Damaged area was crop out and an insert was installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 26 March 2007 Resolved
Show proper operation of vapor detector
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2007
Resolved 28 March 2007
Resolution: proper operation demonstrated.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 26 March 2007 Resolved
Show proper operation of curtain drop for the port curtain.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2007
Resolved 28 March 2007
Resolution: Proper operation demonstrated.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 March 2006 Resolved
Install safety wire on shaft bushing cap.
Due 2 April 2006
Resolved 3 April 2006
Resolution: Wire installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 February 2005 Resolved
Post COI and stability letter
Due 21 March 2005
Resolved 28 February 2005
Resolution: Posted.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 21 February 2005 Resolved
Show proper operation of vapor detector in engine compt..
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2005
Resolved 28 February 2005
Resolution: Proper operation demonstrated.
Lifesaving › Hand Flares
Issued 3 December 2003 Resolved
Provide watertight box, labeled, for flares. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 1 April 2004
Resolution: Watertight box provided.
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 December 2003 Resolved
Label all child life jackets. LEGACY COMPONENT DESC: Marking
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 1 April 2004
Resolution: Jackets labeled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 3 December 2003 Resolved
Provide a means to secure the discharge safety pin. LEGACY COMPONENT DESC: Condition
Due 2 January 2004
Resolved 1 April 2004
Resolution: Portable fire bottles serviced.
Construction/Loadline › Penetrations
Issued 3 December 2003 Resolved
Install double hose clamps at each end of stuffing box. LEGACY COMPONENT DESC: Pipe Flange
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 1 April 2004
Resolution: Double hose clamps installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 May 2003 Resolved
Prior to carrying passengers properly mark all life jackets and life rings with the vessel name. LEGACY COMPONENT DESC: Marking
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 14 May 2003

Ownership record