MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 27

STRETCH DUCK 27 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2003, most recently in August 2019, along with 26 deficiencies — 2 with no resolution recorded —.

Records from 2003 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

607145
Flag
UNITED STATES
—
Maury page id
psix-607145

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 13 calendar years (2003–2019)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788077
9 May 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6680357
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622665
29 October 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6570353
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519682
21 March 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6388131
9 February 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6352629
9 January 2017 COI Inspection · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6068153
24 March 2016 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5840111
5 January 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5791445
7 February 2012 COI Inspection · Damage Survey · Hull Examination · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4236256
21 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4162273
1 September 2010 Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3835245
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653021
26 January 2009 Examination of Repairs · Internal Structural Exam · Initial Certification · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3400184
2 February 2007 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2865854
2 March 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2594459
21 February 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2296453
2 August 2004 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2153676
24 July 2004 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2143563
24 July 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2156639
1 December 2003 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1956837
24 March 2003 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1779052
27 February 2003 Construction Oversight · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1740647
27 January 2003 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1730611

Deficiency record · 26

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Demonstrate compliance with new Conditions of Operation listed on amended COI.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Bilge Water Management System › Piping
Issued 21 March 2018 No resolution recorded
Bilge piping and GPM rate is not in compliance with MSC Letter E1-0504811. Vessel to operate with 2 total hand bilge pumps and will require manning as appropriate. This is to be corrected by 2019 operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 21 February 2018 Resolved
Prove repair of water leak at steering box penetration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2018
Resolution: Steering box removed and seal replaced. Float test all sat.
Construction/Loadline › Hull › Stiffener
Issued 24 January 2017 Resolved
Identified external structural member, starboard side, in way of prop tunnel that appeared to have a leak allowing water into the external structural member.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 26 January 2017
Resolution: Recieved email identifying repair of pinhole discovered in the external structural member.
Electrical › Electric Supply System (service) › Cable
Issued 7 February 2012 Resolved
Dead end cable left in midbody section of vessel below passenger accomadation area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2012
Resolution: Operator removed unused cable.
Communications › Public Address System › Loudspeaker
Issued 7 February 2012 Resolved
PA system inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2012
Resolution: Operator proved proper operation.
Engineering › Bilge Water Management System › Not Operational
Issued 7 February 2012 Resolved
Three bilge pumps failed to operate at required capacity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2012
Resolution: Three new, Rule pumps installed and operator proved proper operation.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 September 2010 Resolved
Emergency procedures for fighting fires did not include closure of floor vents prior to discharging fixed CO2 system.
Action required: 705 - Other - as specified
Resolved 2 September 2010
Resolution: Procedures updated.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 September 2010 Resolved
Only one battery operated lantern found during inspection.
Action required: 705 - Other - as specified
Resolved 2 September 2010
Resolution: Second battery operated lanterned found on board vessel.
Engineering › Fuel Oil Service System › Valve, Control
Issued 1 September 2010 Resolved
Position of fuel shutoff valve handle located on vessel fire wall near operating station was not self indicating (i.e. unable to determine if valve was in the open or closed position).
Action required: 705 - Other - as specified
Resolved 2 September 2010
Resolution: Valve labeled with open and closed positions.
Engineering › Bilge Water Management System › Piping
Issued 1 September 2010 Resolved
Starboard side rear bilge pipe restricted flow during test of bilge system.
Action required: 705 - Other - as specified
Resolved 2 September 2010
Resolution: Operator cleared pipe of debris and proved proper operation of bilge discharge system.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 21 September 2011
Resolution: System modified to reduce maximum pressure to 15 psi or less excluding unfired pressure vessel from requirement.
Construction/Loadline › Hull › Bottom Plating
Issued 2 March 2006 Resolved
Address rust pockets located at the right front wheel well as well as other areas identified by inspector.
Due 2 April 2006
Resolved 3 April 2006
Resolution: Rust removed and recoated.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 March 2006 Resolved
Show proper operation of the starboard side curtian.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2006
Resolved 3 April 2006
Resolution: satisfactory test of side curtain.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 21 February 2005 Resolved
SHOW PROOF OF PROPER OPERATION OF VAPOR DETECTOR IN EWNGINE COMPT..
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2005
Resolved 28 March 2005
Resolution: Proper operation demonstrated.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 2 August 2004 Resolved
Make repairs to the power take-off for the propulsion shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2004
Resolved 2 August 2004
Resolution: Repairs made.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 July 2004 Resolved
Prior to carrying passengers, conduct satisfactory underway test of propeller and propulsion systrems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 2 August 2004
Construction/Loadline › Penetrations
Issued 1 December 2003 Resolved
Provide double hose clamps on each end of stuffing box. LEGACY COMPONENT DESC: Pipe Flange
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 1 April 2004
Resolution: Double hose clamps installed.
Lifesaving › Lifebuoys
Issued 1 December 2003 Resolved
Install non corrosive clip on waterlight lanyard. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 1 April 2004
Resolution: Clip installed.
Lifesaving › Hand Flares
Issued 1 December 2003 Resolved
Provide watertight box, labeled, for flares. LEGACY COMPONENT DESC: Storage
Due 2 January 2004
Resolved 1 April 2004
Resolution: Watertight box provided.
Lifesaving › Lifebuoys
Issued 1 December 2003 Resolved
Provide retro tape for ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 1 April 2004
Resolution: Retro tape on ring.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 March 2003 Resolved
Ensure all life jackets and ring buoys have been marked with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003
Communications › Radio Communications
Issued 24 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 24 April 2003
Resolved 21 April 2003
Resolution: Vsl is rqd by local BALMS policy to have a VHF radio O/B but is not required by regulation to have an FCC Station License, Safety Certificate or Marine Operators Permit.
Navigation › Emergency Steering
Issued 27 February 2003 Resolved
Install functional emergency tiller.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2003
Construction/Loadline › Hull
Issued 27 February 2003 Resolved
Properly repair leaks in hull by steering box and emergency tiller. LEGACY COMPONENT DESC: Side Shell
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2003
Resolved 12 March 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 February 2003 Resolved
Label all PFD's and Life rings with vessel name.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.