MAURY USCG vessel records
← All vessels

LSL-F1

LSL-F1 is a 1943 tank barge. The Coast Guard has recorded 23 inspections since 2003, most recently in December 2014, along with 10 deficiencies.

Records from 2003 to 2014. Most recent: inspection, 5 December 2014.

Built
1943
Last inspected
5 December 2014
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 5 December 2014
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2003–2014)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

607234
Flag
UNITED STATES
Maury page id
psix-607234

Documentation record

Tonnage as PSIX records it685 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

5 December 2014 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5034730
8 April 2014 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4831485
24 May 2012 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4320692
22 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4318679
15 June 2011 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4045819
15 June 2011 COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4060209
10 June 2011 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4045571
3 December 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3373631
15 October 2008 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3345977
16 April 2008 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3185453
17 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3081833
20 September 2007 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3075402
16 August 2007 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3057748
28 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2879184
18 October 2006 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2803812
2 March 2006 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2594485
28 February 2006 Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2593447
28 February 2006 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2594476
11 January 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2272758
11 January 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2272781
27 February 2004 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2013452
24 September 2003 Initial Certification · Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1912044
16 January 2003 Deadweight Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1731276

Deficiency record · 10

Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 June 2011 Resolved
During CG inspectors discovered tank barge LSL-F1 failed to complete a USCG annual inspection within the time frame specified by regulation. Issued CG-835 requiring vessel to complete a full COI exam prior to any cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2012
Resolution: New COI issued on 15JUN2011.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008 Resolved
-The VRP must be amended to state that training regimens apply to the qualified and alternate qualified individuals, and members of the spill management team per Reg 33 CFR 155.1055 -The geographic-specific appendices in the VRP must be amended to align with the 33 CFR Part 3 technical amendments to reflect the introduction of Sector Commands.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008 Resolved
-Per Reg 33 CFR 155.1040(k), the barge-specific appendix must be amended to include the individual capacities of all ballast tanks.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 20 September 2007 Resolved
Install emergency shutdown signs for each pump system on board.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 17 October 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 October 2006 Resolved
Submit plans for electrical systems in use in hazardous locations on the barge to the Marine Safety Center for approval.
Due 21 March 2007
Resolved 16 August 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 October 2006 Resolved
Ensure electrical installations on the barge are compliant with requirements for hazardous locations.
Due 1 May 2007
Resolved 16 August 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 28 February 2006 Resolved
REPAIR LOOSE ELECTRICAL WIRING AT THE BASE OF BOTH THE PORT AND STBD FORWARD RUNNING LIGHTS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 20 March 2006
Resolution: CORRECTED.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 28 February 2006 Resolved
REPLACE THE FLAME SCREEN ON THE ON DECK TANK (MARKED "MOBILE") WHICH HAS BEEN PAINTED OVER.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 20 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 February 2006 Resolved
PROVIDE PROPER MOUNTING BRACKET FOR FIRE EXTINGUISHERS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 20 March 2006
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 28 February 2006 Resolved
Failure to conduct required annual and periodic inspections (missed two inspections, one in 2004 and one in 2005).
Due 28 February 2006
Resolved 20 March 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.