Records from 2016 to 2026. Most recent: inspection, 2 March 2026.
Documentation record
Registered dimensions (L × B × D)33.8 ft × 10.9 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE YACHT SALES INC · BELLINGHAM, WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN SPRINGS, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
2 March 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8318745
15 January 2026
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8297016
31 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8102481
23 October 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8093536
2 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7888490
2 February 2024
Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859893
21 February 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7639305
29 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7420929
31 January 2022
Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7388182
3 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7149787
6 May 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949043
11 February 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6906965
8 January 2020
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6885591
5 February 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620154
5 February 2018
Administrative Inspection · DAPI Audit · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6350011
12 April 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6123175
7 February 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084186
2 September 2016
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5990500
14 March 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833984
18 February 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5822951
1 February 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5807652
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Marine Inspector found 14 degraded life jackets on board. Vessel's passenger count is reduced to 18 until a life jacket can be proved for each person on board.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 March 2026
Resolution: Vessel replaced worn lifejackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2026
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets, with an attached lanyard. Marine Inspector found 2 fire buckets with broken lanyards.
46 CFR 181.610
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 24 March 2026
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 April 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must:
Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessels pre-engineered system failed to shutdown engine.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 2 April 2024
Resolution: Vessel was able to figure out the problem and retest in the presence of [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2024
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels steering packing gland has a minor leak. Repairs have been deferred until next DD. Leak is to be monitored and if it gets worse the operator is to notify the CG and affect repairs immediately.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2026
Resolved 11 February 2026
Resolution: Confirmed leak rectified during engine repower. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2021
Resolved
Vessel is required to have hand bilge pump with suitable hoses for pumping discharge overboard. Vessel did not have portable bilge pump available.
46 CFR 182.25-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 8 April 2021
Resolution: Vessel submitted objective evidence clearing def.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 1 April 2021
Resolved
Vessel did not have valid radio-telephony certificate on-board. Renew certificate and provide copy to Marine Inspector.
46 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 6 May 2021
Resolution: Vessel submitted copy of renewed certificate
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 March 2020
Resolved
Fireboy in machinery space did not automatically shutdown the engines. A device must be provided to automatically shutdown the engines in the protected space. Provide satisfactory service report and demonstrate fully operable as designed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2020
Resolution: Witnessed satisfactory operation of engine shutdown and verified satisfactory servicing report from [name withheld] & Services, Inc.
Engineering › Fuel Oil Service System › Filter
Issued 14 March 2017
Resolved
Fuel filter in engine compartment installed without bowl on bottom for flame protection.
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 12 April 2017
Resolution: Verified that fuel filter in engine compartment was replaced with new fuel filter with flame screen.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 March 2017
Resolved
All around white light not operational.
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 12 April 2017
Resolution: Verified that all around white light was operational.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 23 February 2016
Resolved
First aid kit was missing required items and had outdated/damaged items.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Purchased required equipment needed for med kit.
Navigation › Piloting/Steering › Marine Charts
Issued 23 February 2016
Resolved
Charts onboard were outdated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Purchased required chart.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 February 2016
Resolved
Five lifejackets were not labeled with name of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: All life jackets were labeled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 February 2016
Resolved
The stowage location of four lifejackets was not marked.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Stowage changed to reflect proper number of life jackets in space.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 February 2016
Resolved
Life float light was not lashed to the life float without a means to remove.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Clasp was added to float light.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 23 February 2016
Resolved
Part of the exhaust piping was missing lagging.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Lagging installed on exhaust pipe.
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 February 2016
Resolved
STBD forward corner of engine compartment was not sealed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Sealed corner of E/R cover.
Engineering › Electric Propulsion System › Battery
Issued 23 February 2016
Resolved
Battery boxes were not secured and moved around.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Battery boxes secured.
Engineering › Gasoline Engine (propulsion) › Timing Belt (4 cycle)
Issued 23 February 2016
Resolved
There was no guard over rotating belt on engine.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Guard placed over alternator belt.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 February 2016
Resolved
EPIRB NOAA registration sticker was on EPIRB housing instead of EPIRB itself.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: NOAA sticker placed on epirb.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 23 February 2016
Resolved
Vessel had no firefighting certificates on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Provided fire protection service report.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 23 February 2016
Resolved
Vessel had no emergency instructions posted at operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Instructions were placed at operating station.
Engineering › Fuel Oil Service System › Gauge
Issued 23 February 2016
Resolved
Lube oil gauge at operating station was unreadable and seemed non-operational.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: New lube oil gauge installed and tested.