MAURY USCG vessel records
← All vessels

HONORABLE WILLIAM WALL

Built
2002
Last inspected
8 January 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 8 January 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 21 calendar years (2003–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH8424
607717
Flag
UNITED STATES
Tonnage
94 - Regulatory (Subpart C or D), Gross Ton 94 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-607717
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 40

8 January 2026 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8291923
21 July 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8191068
9 May 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7908445
4 December 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7833449
18 January 2023 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7611916
14 November 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7577406
13 January 2022 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7379740
26 August 2020 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7041481
9 June 2020 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6972351
24 February 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6914506
31 October 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6846619
25 September 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6547083
29 November 2017 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6314029
31 August 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6255583
12 September 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5998436
14 September 2015 COI Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5718700
22 April 2015 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5109069
7 October 2014 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5000493
16 October 2013 Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4735427
15 July 2013 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4653794
18 April 2012 Annual Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4290496
27 October 2011 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4177250
7 July 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4072660
14 September 2010 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3865138
10 May 2010 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3734827
25 February 2010 Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3687667
26 August 2009 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3576467
25 March 2009 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3439955
21 April 2008 Deadweight Survey · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3176040
21 April 2008 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3189169
15 August 2007 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3031004
26 February 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2877585
26 December 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2846223
14 November 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2820521
23 June 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2688948
5 June 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2670434
29 March 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2611755
17 February 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2587443
15 February 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2585867
27 February 2003 Administrative Inspection · COI Inspection · MARPOL Annex V Examination · Plan Review "T" Boat · Plan Review (Other than "T")
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1750347

Deficiency record · 117

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2025 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2025 — due date passed with no resolution recorded
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 21 July 2025 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. MIs observed no locking mechanism for the sewage discharge pipe. Install a locking mechanism within the allotted time.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2025
Resolved 8 January 2026
Resolution: Observed lock on discharge line end
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2025 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. Vessel only had 2 serviceable ring life buoys, replace the final ring life buoy within the allotted time.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2025
Resolved 8 January 2026
Resolution: Replaced all ring buoys
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 May 2024 Resolved
Any vsl of at least five net tons which engages in..coastwise trade must have a valid certificate of documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel does not currently have a valid COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Vessel was issued a valid COD
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2023 Resolved
An adult life jacket must be provided for each person carried on board. The COI requires 160 adult life jackets and the vessel only has 158.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2025
Resolution: Checked lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The adult and child life jackets were stowed in a manner that allowed for them to become combined and misidentified.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2024
Resolved 21 July 2025
Resolution: Checked lifejacket stowage
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2023 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. The vessel currently only has one life buoy in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2025
Resolution: Check lifebuoy arrangements
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel had a fuel leak in the generator at the fuel injector port.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 21 July 2025
Resolution: Checked generator fuel system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2023 Resolved
Connections must be made to battery terminals with permanent type connectors The connections on the battery were not of a permanent type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 21 July 2025
Resolution: Checked battery arrangements
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 November 2022 Resolved
A Certificate of Inspection may be suspended and withdrawn or revoked by the cognizant OCMI at any time for noncompliance with the requirements of this subchapter. Vessel did not complete their annual inspection within required timeline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: COI Completed on this date.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 November 2022 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: A paint locker; and a storeroom containing flammable liquids. Additionally, Paint and flammable liquid lockers must be constructed of steel or equivalent material, or wholly lined with steel or equivalent material. Vessel improperly stowed flammable and combustible materials within a space below the main deck without an approved type paint locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: Paint Removed from the space. Space in question does not meet the criteria necessary to require fixed suppression or alternate arrangements.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 November 2022 Resolved
On a vessel of more than 65 feet in length, each hose must be a lined commercial fire hose that conforms to UL 19, be 50 feet in length and 1.5 inches in diameter; and have fittings of brass or material that comply with NFPA 1963. Observed multiple holes in south side fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: South fire station hose renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 November 2022 Resolved
A hatch cover must have securing devices; and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Vessel’s North and South watertight hatches were not operable due to rolled gaskets and seized dogs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: Tested all watertight hatch opens as appropriate. All opened satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 November 2022 Resolved
A hatch cover that provides access to accommodation spaces must be operable from either side. Vessel’s emergency escape hatch was blocked from use and did not operate from one side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: Vessel's emergency escape was operated and was deemed operable from both directions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel had a fuel leak in the generator at the fuel injector port.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2025
Resolution: Check generator fuel system
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 November 2022 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. Vessel could not produce records of completed fire fighting, man overboard, and abandon ship drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2023
Resolution: Sufficient records supplied.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 November 2022 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 and Three hand orange smoke distress signals approved in accordance with § 160.037. Vessel’s distress signals were expired.
Action required: 705 - Other - as specified
Resolved 18 January 2023
Resolution: Distress Signals provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 November 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel and must have a sufficient number of urine-specimen collection and shipping kits meeting the requirements of 49 CFR part 40 that are readily accessible for use following SMIs. Vessel did not have testing kits required on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: Test Kits provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 November 2022 Resolved
A vessel must carry adequate and up-to-date Charts, U.S Coast Pilot [name withheld], Tide Tables, and Current Tables. All of the vessel’s charts and publications were outdated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2023
Resolution: Updated charts provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 November 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel’s first aid kit contents were expired and/or missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2023
Resolution: First Aid Kit Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2022 Resolved
Electrical equipment must be protected from the weather and be watertight, upper deck bar outlet must meet this.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2023
Resolution: GFI outlet installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 November 2022 Resolved
Vessel must be in compliance with 46CFR 16 Chemical Testing Compliance; vessel does not have a policy statement, EAP hot-line number displayed, supervisor 1hr EAP training, copy of last MIS report and all current employees are on compliance list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: Associated DAPI program requirments met.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 14 November 2022 Resolved
Vessels manning and recommended crew training is the responsibility of the Coast Guard and marine employer; vessels crew was not familiar with all operations of the vessels safety equipment during emergency situations and none of the crew are current in CPR or first aid.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2023
Resolution: All members of the crew currently certified CPR.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 August 2020 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher. Fire extinguishers are past due for annual servicing. 46 CFR 176.810 (a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2020
Resolved 27 August 2020
Resolution: Received documentation of fire extinguisher servicing.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 August 2020 Resolved
Licensees of radio stations are required to have current station documents as indicated in the following table: FCC Safety Radiotelephony Certificate. Current certificate is expired. 47 CFR 80.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 27 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2020 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Both floating water light bateeries are expired and the wrong model number of the batteries are being used IAW manufacturer. 46 CFR 185.726 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 16 September 2020
Resolution: Received photos of new light with new batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Several electrical enclosures are missing covers (void #1 and aft stbd void). 46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 16 September 2020
Resolution: Received photos of all enclosures with proper covers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2020 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q. Aft ring life buoy has deteriorated grab lines and needs to be replaced. 46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 16 September 2020
Resolution: Received photos of new life ring with appropriate markings.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 August 2020 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required. Both fire stations are missing spanner wrenches. 46 CFR 181.310 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 16 September 2020
Resolution: Received photos of both spanner wrenches installed at fire stations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2020 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Battery charger in machinery space did not have an ammeter. Install ammeter in battery charging circuit in machinery space within 07 days - 02MAR2020.
Action required: 705 - Other - as specified
Due 2 March 2020
Resolved 29 June 2020
Resolution: Received emails of pictures. Satsfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2020 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. High bilge alarm wiring connectoins in voids #1, #2, and #3 were not in an enclosure, high bilge alarm switches were not secured to the vessel. Secure high bilge alarm switches in voids #1, #2, and #3 and put wiring connections in enclosures within 07 days - 02MAR2020.
Action required: 705 - Other - as specified
Due 2 March 2020
Resolved 29 June 2020
Resolution: Received emails of pictures. Satsfactory repairs.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 31 October 2019 Resolved
Update emergency instructions to reflect practical operations for this vessel. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: Vessel submitted photo of revised and posted instructions.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 31 October 2019 Resolved
Make avaialable onboard a written waste management plan for garbage. 33 CFR 151.57
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: Vessel submitted photo of revised and posted instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2019 Resolved
02 liferings were no longer servicable. Replace at least 01 ring to meet COI. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: Vessel submitted photo of new life rings on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2019 Resolved
01 of 02 lights for ring buoy does not have metalic clip. provide clip for light. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: vessel submitted photo of new clip properly affixed to light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2019 Resolved
Portable fire extinguishers msut be installed in required marine brackets as indicated on the extinguisher. Install required brackets fo all portable extinguishers. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: Vessel submitted pictures of 3 fire extinguisher brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 October 2019 Resolved
Repair leak of fuel oil to generator near base of generator. 46 CFR 182.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: operator cleaned piping and could not locate leak; monitoring will continue.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 31 October 2019 Resolved
Penetration near overhead between Norht and South storage must be made watertight. Also between generator room and N. Store.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 3 December 2019
Resolution: operator submitted photo of repaired wire run.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2018 Resolved
The fram or support of each semi-portable fire extinguisher must be welded or otherwise attached to a bulkhead or deck. Passenger barge had portable fire extinguisher not attched to bulkhead with correct bracket. 46CFR181.500(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 16 October 2018
Resolution: Recieved picture of fire extinguisher in correct mounting bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018 Resolved
Each life buoy on a vessel must be approved in accordance with 160.150 Subchapter Q. 3 lifebuoys were deteriated and need replaced. 46CFR180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 16 October 2018
Resolution: ALl life buoys were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018 Resolved
Each floating waterlight must be approved in accordance with 161.010 Subchapter Q. Barges waterlight was cracked and needs replaced. 46CFR180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 16 October 2018
Resolution: Replaced broken water light with new one.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2018 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Barge had 4 navigation/mooring lights that were not secured properly and had loose cables. 46CFR183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 16 October 2018
Resolution: Lights were properly secured.
Construction/Loadline › Hull › Side Shell
Issued 29 November 2017 Resolved
MW01: Submit repair proposal to address bolt holes in hull filled with 5200 for holes within 1 foot of deepest load waterline.
Action required: 705 - Other - as specified
Resolved 1 December 2017
Resolution: Received photos.
Documentation › Logs/Records › Logbook (official)
Issued 12 September 2016 Resolved
The vessel's monthly rescue boat log was missing. Corrected during the inspection. Inspector provided training and the crew began monthly logs.
Due 12 September 2016
Resolved 12 September 2016
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 September 2016 Resolved
Lifejacket instructions werer missing at the station.
Due 12 September 2016
Resolved 12 September 2016
Resolution: Crew members replaced the missing life jacket instructions during the inspection.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 September 2016 Resolved
The vessel was missing the emergency broadcast radio placard.
Due 12 September 2016
Resolved 12 September 2016
Resolution: Operator provided a laminated emergency radio call plaque at the operating station prior to the completion of the inspection.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 15 September 2015 Resolved
1) Replace cracked inspection hatch on sea chest for emergency fire pump. (To be replaced at drydock OCT-NOV 2015)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 14 December 2015
Electrical › Electric Generation Source (service) › Generator
Issued 15 September 2015 Resolved
2) Provide technical report addressing coolant leak and repair on generator.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 14 December 2015
Construction/Loadline › Hull › Hull Plating
Issued 15 September 2015 Resolved
3) Repair identified hull inset on "West" side hull plating prior to credit drydock. (To be repaired at drydock OCT-NOV 2015)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 December 2015
Electrical › Electric Generation Source (service) › Ground Detection
Issued 15 September 2015 Resolved
4) Provide ground detection for dual voltage generator.
Condition: Invalid
Due 30 November 2017
Resolved 18 October 2018
Resolution: MI verified ground detection installation during vessels 3rd annual inspection.
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 October 2014 Resolved
AF01- Post lifejacket placards near lifejacket stowage areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2014
Resolution: Posted lifejacket placards near the lifejacket stowage area prior to completion of inspection.
Documentation › Certificates/Documents › FCC SSL
Issued 7 October 2014 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 7 November 2014
Resolved 12 September 2016
Resolution: MI's corrected def during 1st annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 October 2014 Resolved
AF03- Replace expired medication in First Aid Kit.
Action required: 705 - Other - as specified
Due 14 October 2014
Resolved 14 October 2014
Resolution: Required items in First Aid Kit procured.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 October 2014 Resolved
Vessel operated from 09Aug14 through 07OCT14 without a valid Certificate of Inspection (COI) onboard.
Due 7 October 2014
Resolved 7 October 2014
Resolution: Vessel completed satisfactory COI.
Documentation › Markings/Placards › Warning Signs
Issued 15 July 2013 Resolved
DS01 - Label emergency escape hatch from generator room.
Action required: 705 - Other - as specified
Due 22 July 2013
Resolved 25 July 2013
Resolution: Permanent labeling installed on escape hatch.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 July 2013 Resolved
DS02 - Remove installed extension cords and ungrounded space heaters.
Action required: 705 - Other - as specified
Due 22 July 2013
Resolved 25 July 2013
Resolution: Extension cords uninstalled from bulkheads.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 July 2013 Resolved
DS03 - Remove or cap dead end wires.
Action required: 705 - Other - as specified
Due 22 July 2013
Resolved 25 July 2013
Resolution: Dead end wires removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 April 2012 Resolved
Connections to battery terminals must be permanent type. Remove all alligator clips from battery terminals.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2012
Resolved 11 May 2012
Resolution: Connections for battery charger made permanent.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2012 Resolved
Place cover over light outside machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2012
Resolved 11 May 2012
Resolution: Cover placed over light.
Documentation › Markings/Placards › Warning Signs
Issued 18 April 2012 Resolved
Label emergency escape hatch in machinery space as per 46 CFR 185.600.
Action required: 705 - Other - as specified
Due 2 May 2012
Resolved 2 May 2012
Resolution: Emergency escape hatch labeled.
Construction/Loadline › Hull › Side Shell
Issued 10 May 2010 Resolved
Fill in three pin holes located in the aft voids space.
Action required: 705 - Other - as specified
Due 10 June 2010
Resolved 7 July 2011
Resolution: All three pin holes filled with 5200.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 May 2010 Resolved
Provide proof of enrollment into DAPI consortium for Dmitry Ilyutovich, the vessel Captain.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2010
Resolution: Received proof of enrollment into a DAPI consortium. Deficiency cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 August 2009 Resolved
Failure to complete 3rd annual inspection.
Action required: 705 - Other - as specified
Due 26 August 2009
Resolved 26 August 2009
Resolution: Inspection conducted.
Engineering › Bilge Water Management System › Pump
Issued 25 August 2009 Resolved
Ensure visual indicator on bilge alarm for engine room operates properly IAW 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 26 September 2009
Resolved 30 September 2009
Resolution: Visual indicator on bilge alarm properly functioning. Deficiency cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 August 2009 Resolved
Properly mount three portable fire extinguishers with manufacturer's approved brackets.
Action required: 705 - Other - as specified
Due 26 October 2009
Resolved 27 October 2009
Resolution: Received email from vessel representative attesting to installation of fire extinguisher brackets. Deficiency cleared.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 August 2009 Resolved
Provide proof of current Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2009
Resolution: Certificate of Documentation was viewed by the attending Marine Inspector.
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 April 2008 Resolved
Cap old sea chest valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: Old sea chest valves were capped off.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 April 2008 Resolved
Complete refit of new railing located near the new landing deck for passenger main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: All railing is re-installed near new landing area.
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2008 Resolved
Complete wiring harness into generator space from main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: Wiring harness to generator was installed to the satifaction of attending MI.
Engineering › Bilge Water Management System › Pump
Issued 21 April 2008 Resolved
Re install bilbe pump in storabe space.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: Bilge pump in engine room was re-installed and operational.
Accommodation/Occupational Safety › Potable Water System › General
Issued 21 April 2008 Resolved
Complete refit of all drainabe and wash down PVC Piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: All PVC piping was refiited or capped off to complete the system.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2008 Resolved
Cap off old wet exhaust pipe located in storage room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: Old wet exhaust pipe was capped off to the satifaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 21 April 2008 Resolved
Install rails at stairwell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Rails installed on both sides of stairwell.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 April 2008 Resolved
Install proper ventilation system in machinery space IAW 46 CFR 182.465.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Ventilation system installed IAW 46 CFR 182.465.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 April 2008 Resolved
Relocate door in way of stairwell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Door removed from joiner bulkhead IWO stairwell.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 April 2008 Resolved
Provide restricted access to stairwell area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Rails installed around stairwell entrance to restrict access.
Engineering › Gasoline Engine (auxiliary) › Exhaust Piping (4 cycle)
Issued 21 April 2008 Resolved
Test generator exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: Tested generator exhaust saisfactorily.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 April 2008 Resolved
Make machinery space vapor tight IAW 46 CFR 177.405(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2008
Resolution: Machinery space made vapor tight with steel plates and watertight door installed on longitudinal bulkead IWO generator/fuel tank room.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 15 August 2007 Resolved
-All vessels portable fire extinguishers are due for annual servicing (all due 6/07). Fax copy of servicing report to USCG. 46CFR 176.810 (b) (2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 16 August 2007
Resolution: Received servicing report.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 15 August 2007 Resolved
Mount BII fire extinguisher IWO captains station. (found noted mounted) 46CFR 176.810 MACHINERY
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 18 October 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 August 2007 Resolved
Provide for training logbook, and show evidence of training conducted every 3 months. 46CFR185.420 (a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 18 October 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 August 2007 Resolved
Renew wasted lifebuoys line (grab) 02 total 46CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 18 October 2007
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 August 2007 Resolved
Mark vessels hull with name/hailing port as per 46CFR67.123
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 18 October 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2007 Resolved
Provide plate covers for electrical outlets IWO bar area, upperdeck. 46CFR183.340.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 18 October 2007
Lifesaving › Rescue Boat › Markings
Issued 15 August 2007 Resolved
Mark rescue boat as per 46CFR 185.604. (i.e. Name, # persons capacity on bow , retro tape).
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 18 October 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 August 2007 Resolved
Provide for evidence of Masters License. (Fax to USCG)
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 16 August 2007
Resolution: Received faxed copy of Masters License.
Engineering › Bilge Water Management System › Piping
Issued 26 February 2007 Resolved
Prior to completion of credit drydock make permanent repairs to rigid non-metallic bilge piping in way of #2 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2007
Engineering › Freshwater Generation System › Piping
Issued 26 February 2007 Resolved
Prior to completion of credit drydock, make permanent repairs to rigid non-metallic piping (PVC) in way of rain water collection system, #2 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 June 2006 Resolved
Provide copy of renewed COD via fax upon receipt.
Condition: Improper/Lack of Maintenance
Due 5 June 2006
Resolved 23 June 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 June 2006 Resolved
Conduct housekeeping on upper deck, bar aread radio wires. Properly terminate loose wires.
Condition: Improper/Lack of Maintenance
Due 5 June 2006
Resolved 23 June 2006
Lifesaving › Emergency Outfit › Fire ax
Issued 5 June 2006 Resolved
Provide fire ax at operating station.
Condition: Improper/Lack of Maintenance
Due 5 June 2006
Resolved 23 June 2006
Fire Fighting › Fire Main › Condition
Issued 19 May 2005 Resolved
Repair minor leaks in firemain.
Action required: 705 - Other - as specified
Resolved 11 August 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 April 2005 Resolved
New certificate of documentation reflecting new gross tonnage was not available.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Documentation › Certificates/Documents › FCC SSL
Issued 15 April 2005 Resolved
Provide FCC Safety Certificate.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Documentation › Certificates/Documents › FCC SSL
Issued 15 April 2005 Resolved
Provide Marine Radio Operators Permit.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Documentation › Certificates/Documents › Stability Letter
Issued 15 April 2005 Resolved
Post stability letter.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 15 April 2005 Resolved
Post Small Passenger Vessel decal.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 April 2005 Resolved
Conduct First Aid training.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 15 April 2005 Resolved
Provide proof of D&A Program IAW 46 CFR 16
Action required: 705 - Other - as specified
Resolved 19 May 2005
Operations/Management › Drills/Instruction › Fire
Issued 15 April 2005 Resolved
Provide bridge and training log and log all training.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 15 April 2005 Resolved
Prove proper operation of VHF radio.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 15 April 2005 Resolved
Post Emergency Broadcast Placard
Action required: 705 - Other - as specified
Resolved 19 May 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 April 2005 Resolved
Provide passenger safety orientation.
Action required: 705 - Other - as specified
Resolved 11 August 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 April 2005 Resolved
Properly attach waterlight to lifering.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 April 2005 Resolved
Provide First Aid kit.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 April 2005 Resolved
Provide proof of annual servicing of all portable fire extingushers.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Fire Fighting › Fire Main › Condition
Issued 15 April 2005 Resolved
Submit plans to Coast Guard for the installation of a firemain system.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Fire Fighting › Fire Main › Material
Issued 15 April 2005 Resolved
Install approved firemain system.
Action required: 705 - Other - as specified
Resolved 11 August 2005
Engineering › Bilge Water Management System › Hose
Issued 15 April 2005 Resolved
Provide longer hose for portable bilge pump.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 April 2005 Resolved
Post signs at the entrance to all voids warning personnel of the dangers because of limited oxygen.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Fire Fighting › Fire Hoses › Condition
Issued 15 April 2005 Resolved
Provide proof that fire hoses meet UL 19.
Action required: 705 - Other - as specified
Resolved 11 August 2005
Lifesaving › Rescue Boat › Propulsion Engine
Issued 15 April 2005 Resolved
Vsl is required to have alongside while passengers are onboard a small boat with motor to recover a MOB.
Action required: 705 - Other - as specified
Resolved 11 August 2005
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 February 2003 Resolved
Provide current operators license.
Action required: 705 - Other - as specified
Resolved 19 May 2005
Fire Fighting › Fire Pumps › Pressure
Issued 27 February 2003 Resolved
Prove proper operation of fire pump at 60 psi.
Due 27 May 2005
Resolved 11 August 2005
Electrical › Electric Generation Source (service) › Generator
Issued 27 February 2003 Resolved
Prove proper operation of AC generator.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 11 August 2005
Electrical › Electric Generation Source (service) › Generator
Issued 27 February 2003 Resolved
Make permanent repairs to wet exhaust water leak.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 31 August 2005
Fire Fighting › Fire Pumps › Casing
Issued 27 February 2003 Resolved
Make permanent repairs to fire pump water leaks.
Action required: 705 - Other - as specified
Due 19 August 2005
Resolved 31 August 2005

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.