BROUSSARD TIDE

BROUSSARD TIDE is a 2003 offshore supply vessel. The Coast Guard has recorded 5 inspections since 2016, most recently in May 2018, along with 18 deficiencies and 2 casualty investigations between 2012 and 2016.

Records from 2012 to 2018. Most recent: inspection, 9 May 2018.

Built
2003
Last inspected
9 May 2018
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 May 2018
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9273519
WDE9877
607977
Flag
UNITED STATES
Maury page id
psix-607977

Documentation record

Registered dimensions (L × B × D)203.1 ft × 46.0 ft × 17.0 ft
Registered tonnagegross 1,235 / net 473
ITC dimensions (L × B × D)203.1 ft × 46.0 ft × 17.0 ft
ITC tonnagegross 1,235 / net 473
BuilderQUALITY SHIPYARDS LLC · HOUMA, LA, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGIBSON, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1235 - Convention (Subpart B), Gross Ton
2220 - Displacement, Gross Ton
473 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OIL RIG DAGDA Mobile Offshore Drilling Unit · MISLE 1430018 · 2 December 2016 · activity 6056169

Inspection history · 5

9 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6409781
23 May 2017 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6133465
8 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6075818
2 December 2016 Type not recorded
No type recorded · Activities Europe · Activity 6056169
25 July 2016 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 5952094

Deficiency record · 18

Lifesaving › Rescue Boat Equipment › Repair Kit (inflated rescue boat)
Issued 25 August 2016 Resolved
Provide proper repair kit. Ensure proper operation of fuel guage and battery charger.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 30 August 2016
Resolution: Completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 August 2016 Resolved
Properly test and stencil all F/O transfer hoses.
Action required: 703 - Prior to bunkering operations
Due 25 September 2016
Resolved 30 August 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 25 August 2016 Resolved
Properly mark F/O and ballast emergency stops on main deck.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 August 2016 Resolved
E-Lights located in E-Generator room, and both staircase not working.
Due 25 September 2016
Resolved 25 August 2016
Resolution: Corrected.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 August 2016 Resolved
Provide for proper closure of both Flam Lockers on main deck. Doors do not seal properly and CO2 would escape if CO2 System was deployed.
Due 25 September 2016
Resolved 1 September 2016
Resolution: Closures provided.
Communications › Alarms/Indicators › Fire Alarm
Issued 25 August 2016 Resolved
Fire alarm signage was painted over. Remove paint or provide new signage. Located in thruster room.
Due 25 September 2016
Resolved 31 August 2016
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 25 August 2016 Resolved
Replace the following guages. Sewage pump, bow thruster engine J/W temp, and hydro pump for fresh water.
Due 25 September 2016
Resolved 2 September 2016
Resolution: Completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 August 2016 Resolved
Provide portable light at entrance to engine room.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed
Communications › Alarms/Indicators › High Water Alarm
Issued 25 August 2016 Resolved
Audible alarm do not sound on the bridge when activated from the fwd thruster room.
Due 25 September 2016
Resolved 25 August 2016
Resolution: Fixed before the end of our inspection.
Engineering › Pressure Vessel › Relief Valve
Issued 25 August 2016 Resolved
Properly test all pressure relief valves on all dry-bulk tanks.
Due 25 September 2016
Resolved 27 August 2016
Resolution: Provide 3rd party certs for all PRV's.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 25 August 2016 Resolved
Provide approved fuel transfer procedures at transfer station.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Posted.
Engineering › Pressure Vessel › Relief Valve
Issued 25 August 2016 Resolved
Provide for proper operation of pressure relief valves on both PV's located in the engine room.
Due 25 August 2016
Resolved 31 August 2016
Resolution: Provided 3rd party certs.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 August 2016 Resolved
Alarm panel next to #3 stbd dry-bulk tank does not sound and needs proper label.
Due 25 September 2016
Resolved 31 August 2016
Resolution: completed
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 25 August 2016 Resolved
High level indicators in the #3 port and #4 center tank not working properly.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 7 September 2016
Resolution: Received email with pictures attached showing alarms indicating lights working properly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 August 2016 Resolved
Remove all boxes and supplies from port side walkway in dry-bulk tank space.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 August 2016 Resolved
Provide light at emergency control station.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed
Communications › Alarms/Indicators › General Alarm
Issued 25 August 2016 Resolved
GA bell located on bridge does not sound while on emergency power.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 5 September 2016
Resolution: Corrected
Communications › Radio Communications › VHF Radiotelephone
Issued 25 August 2016 Resolved
Provide 01 VHF radio to work on emergency power.
Due 25 September 2016
Resolved 5 September 2016
Resolution: Corrected

Casualty record · 2

8 February 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4243218
2 December 2016Routine · role: Involved in a Marine Casualty · activity 6056169
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.