Records from 2003 to 2018. Most recent: inspection, 9 May 2018.
Documentation record
Registered dimensions (L × B × D)203.1 ft × 46.0 ft × 17.0 ft
Registered tonnagegross 1,235 / net 473
ITC dimensions (L × B × D)203.1 ft × 46.0 ft × 17.0 ft
ITC tonnagegross 1,235 / net 473
BuilderQUALITY SHIPYARDS LLC · HOUMA, LA, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGIBSON, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1235 - Convention (Subpart B), Gross Ton
2220 - Displacement, Gross Ton
473 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
9 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6409781
23 May 2017
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6133465
8 December 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6075818
2 December 2016
Type not recorded
No type recorded · Activities Europe · Activity 6056169
25 July 2016
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 5952094
20 May 2014
Administrative Inspection
Administrative · Activities Europe · Activity 4864919
8 February 2012
Type not recorded
No type recorded · Activities Europe · Activity 4243218
26 January 2009
Annual Inspection
Physical examination · Activities Europe · Activity 3402594
11 March 2008
Administrative Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3162049
31 January 2007
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2864684
27 May 2006
Re-Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2664612
29 June 2005
ACP Annual Oversight
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2407937
16 February 2005
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2293511
6 December 2004
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2300957
4 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2257043
29 September 2004
ACP Annual Oversight
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2208391
7 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066550
28 February 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2014722
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971499
2 June 2003
ACP COI Oversight · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1808076
Lifesaving › Rescue Boat Equipment › Repair Kit (inflated rescue boat)
Issued 25 August 2016
Resolved
Provide proper repair kit. Ensure proper operation of fuel guage and battery charger.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 30 August 2016
Resolution: Completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 August 2016
Resolved
Properly test and stencil all F/O transfer hoses.
Action required: 703 - Prior to bunkering operations
Due 25 September 2016
Resolved 30 August 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 25 August 2016
Resolved
Properly mark F/O and ballast emergency stops on main deck.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 August 2016
Resolved
E-Lights located in E-Generator room, and both staircase not working.
Due 25 September 2016
Resolved 25 August 2016
Resolution: Corrected.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 August 2016
Resolved
Provide for proper closure of both Flam Lockers on main deck. Doors do not seal properly and CO2 would escape if CO2 System was deployed.
Due 25 September 2016
Resolved 1 September 2016
Resolution: Closures provided.
Communications › Alarms/Indicators › Fire Alarm
Issued 25 August 2016
Resolved
Fire alarm signage was painted over. Remove paint or provide new signage. Located in thruster room.
Due 25 September 2016
Resolved 31 August 2016
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 25 August 2016
Resolved
Replace the following guages. Sewage pump, bow thruster engine J/W temp, and hydro pump for fresh water.
Due 25 September 2016
Resolved 2 September 2016
Resolution: Completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 August 2016
Resolved
Provide portable light at entrance to engine room.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed
Communications › Alarms/Indicators › High Water Alarm
Issued 25 August 2016
Resolved
Audible alarm do not sound on the bridge when activated from the fwd thruster room.
Due 25 September 2016
Resolved 25 August 2016
Resolution: Fixed before the end of our inspection.
Engineering › Pressure Vessel › Relief Valve
Issued 25 August 2016
Resolved
Properly test all pressure relief valves on all dry-bulk tanks.
Due 25 September 2016
Resolved 27 August 2016
Resolution: Provide 3rd party certs for all PRV's.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 25 August 2016
Resolved
Provide approved fuel transfer procedures at transfer station.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Posted.
Engineering › Pressure Vessel › Relief Valve
Issued 25 August 2016
Resolved
Provide for proper operation of pressure relief valves on both PV's located in the engine room.
Due 25 August 2016
Resolved 31 August 2016
Resolution: Provided 3rd party certs.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 August 2016
Resolved
Alarm panel next to #3 stbd dry-bulk tank does not sound and needs proper label.
Due 25 September 2016
Resolved 31 August 2016
Resolution: completed
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 25 August 2016
Resolved
High level indicators in the #3 port and #4 center tank not working properly.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 7 September 2016
Resolution: Received email with pictures attached showing alarms indicating lights working properly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 August 2016
Resolved
Remove all boxes and supplies from port side walkway in dry-bulk tank space.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 August 2016
Resolved
Provide light at emergency control station.
Due 25 September 2016
Resolved 31 August 2016
Resolution: Completed
Communications › Alarms/Indicators › General Alarm
Issued 25 August 2016
Resolved
GA bell located on bridge does not sound while on emergency power.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 5 September 2016
Resolution: Corrected
Communications › Radio Communications › VHF Radiotelephone
Issued 25 August 2016
Resolved
Provide 01 VHF radio to work on emergency power.
Due 25 September 2016
Resolved 5 September 2016
Resolution: Corrected
Electrical › Electric Generation Source (service) › Generator
Issued 13 February 2009
Resolved
Make proper repairs to the cooling lines on all SSG. Received e-mail 31May09 advising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Due 14 May 2010
Resolved 21 May 2010
Resolution: Inspected satisfactory.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 February 2009
Resolved
Properly install on the Port MDE the purple piece of wire with approve wire.
Condition: Unknown
Due 28 February 2009
Resolved 15 February 2009
Resolution: Corrected while onboard.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 13 February 2009
Resolved
Replace damaged Fireman suit. Received e-mail 31May09 advising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Due 14 May 2010
Resolved 21 May 2010
Resolution: Inspected satisfactorily.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 13 February 2009
Resolved
Make permanent repairs to the gyro repeater's bracket in the after steering flat. Received e-mail 31May09 advising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Due 14 May 2010
Resolved 21 May 2010
Resolution: Inspected satisfactorily.
Engineering › Thrusters › Motor
Issued 29 September 2004
Resolved
Drop down bow thruster damaged after grounding. ABS attending drydock.
Condition: Damaged By Earlier Event
Due 6 November 2004
Resolved 6 December 2004
Resolution: Attended vessel on drydock at Quality Ship YArd, Houma, LA all Repairs satisfactory.