← All vessels
MULTAN
Freight Ship · Bulk Carrier class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named MULTAN
MULTAN is a 2002 freight ship. The Coast Guard has recorded 15 inspections since 2003, most recently in September 2010, along with 4 deficiencies and 6 operational controls.
Records from 2003 to 2010. Most recent: operational control imposed, 27 September 2010.
- Built
- 2002
- Last inspected
- 27 September 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9241671 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
AQQI
607979
Flag
SINGAPORE
—
Maury page id
psix-607979
Inspections, by type
…with no type recorded5
Years with a record
7 calendar years (2003–2010)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it27986 - Convention (Subpart B), Gross Ton
17077 - Convention (Subpart B), Net Ton
50244 - Dead Weight, Ton
59136 - Displacement, Ton
17077 - Convention (Subpart B), Net Ton
50244 - Dead Weight, Ton
59136 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
27 September 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3857803
27 September 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3858861
20 April 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3456805
2 April 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3440924
9 September 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3053483
16 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2872970
16 February 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2873167
10 February 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2870186
7 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2706515
30 October 2005
NPV Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2524475
8 February 2005
Ballast Water Examination · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2289222
25 November 2004
ILO-147 Exam · STCW 95 Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2246597
11 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2004961
30 January 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1737687
29 January 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1737323
Deficiency record · 4
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 April 2009
Resolved
No record for a hydrostatic pressure test for bunkering lines.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 April 2009
Resolved
Temporary patch found on seawater cooling pipe for the jacket water cooler servicing the General Service Generators.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 February 2007
Resolved
Vessel was granted Deviation to Enter with one inop radar.
Engineering › Lubricating Oil Service System › Pump
Issued 10 February 2007
Resolved
Vessel has two main engine lube oil pumps one is currently inoperable. Repair main lube oil pump to the satisfaction of class on behalf of flag. Prior to departure class is to provide a survey report detailing the nature of deficiency, corrective action taken, and vessel's ability to operate and sail.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.