Records from 2003 to 2007. Most recent: inspection, 24 January 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 14 June 2006
Resolved
Prove charts are corrected utilizing local notice to mariners.
Due 14 July 2006
Resolved 14 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2006
Resolved
Prove operation of stern light.
Due 14 July 2006
Resolved 14 July 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2006
Resolved
Provide 2005 List of Lights.
Due 14 July 2006
Resolved 14 July 2006
Engineering › Steering Gear System › Rudder Stock
Issued 14 June 2006
Resolved
Provide satisfactory rudder stops as per 46 CFR 182.610 (e)
Due 14 July 2006
Resolved 14 July 2006
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2004
Resolved
Demonstrate proper operation of generator overspeed shut downs IAW 46 CFR 183.320
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 16 August 2004
Resolution: Overspeed tests, completed.
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S1, Rev D, Midship Sectoin, approved by ABS Americas on Sep. 18, 2001.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide copy of ABS approval letter dated Sep 18, 2001 for the structural drawing submittals: 305-S1, 305-S3, 305-S10, 305-S11, & 305-S14.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S3, Rev D, Frames B, A, O, 1, approved by ABS Americas on Sep. 18, 2001.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S5, Rev D, Frames 6, 7, 8, & 9, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S6, Rev B, Frames 10, 11, 12, & 13, approved by ABS Americas on Apri 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S8, Rev B, Frames 18 thru 22, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S9, Rev B, Frames 23, 24, 25, & 26, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S12, Rev B, Frames 35, 36, & Transom, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide copy of ABS approval letter dated Apr 22, 2002 for the structural drawing submittals: 305-S5, 305-S6, 305-S18, 305-S9, 305-S12, 305-S21, & 305-S23.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No 305-S17, Rev-, Shell Expansion, approved by ABS Americas on Feb 13, 2001.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S20, Rev C, Main Deck House bulkheads, approved by ABS Americas on Jul 9, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide copy of ABs approval letter dated Jul 9, 2002 for Dwg. No 305-S20.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No 305-S21, Rev A, Deck house Top Plating, approved by ABS Americas on April 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S23, Rev B, Pilot [name withheld], approved by ABS Americas on April 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S24, Rev D, Pilot [name withheld], approved by ABS Americas on Oct. 30, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide copy of ABS approval letter dated Oct 30, 3003 for Dwg No. 305-S24.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No. 305-S25, Rev A, Bulwark Details approved by ABS Americas on Sep 10, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide copy of ABS approval letter dated march 26, 2003 for Dwg. No. 305-S25.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No. 305-S26, Rev A, Seachests, approved by ABS Americas on Sep 10, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide copy of ABS approval letter dated Sep 10, 2002 for Dwg No. 305-S26.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No 305-P11, Rev C, Air Intake diagram, approved by ABS Americas on mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. Sketch, Rev -, Bow Thruster COmpartment Hatch, approved by ABS Americas on Mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No Sketch, Rev. -, Longitudinal Bulkhead 11 ft off centerline, approved by ABS Americas on Mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No. Sketch, Rev -, Emergency Escape Hatch, approved by ABS Americas on Mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of Diamond/Sea Glaze Dwg. No. 400 F & 106 F, Rev. -, approved by ABS Americas on Mar 10, 2003 with applicable approval letter.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of Freeman Marine Equipment Dwg. No. 2433-0002 & 2424-002, Rev - , approved by ABS Americas on mar 10, 2003 along with applicable approval letter.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of EACCO Dwg No. D-001, Rev -, Quick Acting Watertight Door, approved by ABS Americas on Mar 10, 2003 along with applicable approval letter.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 April 2003
Resolved
Provide Coast Guard approved plans with approval letter for fixed fire supproession system as required by 46 CFR 177.202(b)(6)(ii).
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 April 2003
Resolved
Provide Coast Guard approved propulsion control system drawing and approval letter as required by 46 CFR 177.202(b)(6)(iii).
Action required: 705 - Other - as specified
Resolved 1 May 2003
Resolution: Resolved through MSC via e-mail from [name withheld].
Accommodation/Occupational Safety › Ventilation › General
Issued 2 April 2003
Resolved
Provide Coast Guard approved plans and review letters for ventilation arrangement demonstrating compliance with 46 CFR 177.600, 46 CFR 177.620, and other applicable section of 46 CFR Subchapter "T" as required by 46 CFR 177.202(b)(3)(iii).
Action required: 705 - Other - as specified
Resolved 12 July 2004
Resolution: Provided copy of review letters that plans had been approved.
Engineering › Steering Gear System
Issued 2 April 2003
Resolved
Provide Coast Guard approved steering control system drawing and approval letter as required by 46 CFR 177.202(b)(3)(ii).
Action required: 705 - Other - as specified
Resolved 14 April 2003
Resolution: Reviewed and approved by MSC as identified in MSC letter E1-0304692/P006976.
Fire Fighting › Fixed Fire Detection System
Issued 2 April 2003
Resolved
Provide Coast Guard approved plans with approval letter for fire detecting & smoke detecting system as required by 46 CFR 177.202(b)(6)(iii).
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Bilge Water Management System
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-P1, Rev -, Bilge/Ballast Piping as noted on MSC Letter 16710/P006976, Serial:E1-0200394, dtd 2/21/2002.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Steering Gear System
Issued 2 April 2003
Resolved
Provide Coast Guard approved plans with approval letter for hydraulic piping installation as rquired by 46 CFR 177.202(b)(8) and MSC letter 16710/P006976 Serial: E1-0300746 dated Mar 6, 2003.
Action required: 705 - Other - as specified
Resolved 14 April 2003
Resolution: Reviewed and approved by MSC as identified in MSC letter E1-0304692.
Operations/Management › Pollution
Issued 2 April 2003
Resolved
Provide for review a copy of transfer procedures as required by 33 CFR 155.720. LEGACY COMPONENT DESC: Compliance with Transfer Procedures
Action required: 705 - Other - as specified
Resolved 17 April 2003
Lifesaving › Rocket Parachute Flares
Issued 2 April 2003
Resolved
Distress flares and smoke signals shall be stowed in a portable watertight container carried at the operating station or in a pyrotechnic locker secured above the freeboard deck in the vicinity of the operating statoin as required by 46 CFR 180.68.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Electrical › Electric Generation Source (service)
Issued 2 April 2003
Resolved
Provide the OCMI with an identical paper copy of A.K. Suda Dwg No 305-E1, Rev B, Electrical One-Line.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Navigation › Piloting/Steering
Issued 2 April 2003
Resolved
Provide for review current and updated charts and publications as required by 46 CFR 1884.420. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Resolved 3 April 2003
Documentation › Certificates/Documents
Issued 2 April 2003
Resolved
Provide for review radio statoin license and installatoin certificates issued by the FCC, as set for in 47 CFR 80 as required by 46 CFR 184.502. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Resolved 3 April 2003
Engineering › Compressed Air System (start air)
Issued 2 April 2003
Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-P8, Rev A, Compressed Air, approved by MSC-2 letter 16710/P006976, Serial: E1-0300745 on 3/24/03.
Action required: 705 - Other - as specified
Resolved 7 April 2003
Engineering › Compressed Air System (start air)
Issued 2 April 2003
Resolved
Provide bill of material specification for compressed air system as noted in MSC-2 Letter 16710/P006976, Serial: E1-0300745 dated 3/24/03, comment.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Provide material spec. documentation of all non-metallic flexible hsoes installed throughout the vessel demonstrating the material meets SAE J-1942 with end fittings meeting SAE J-1475 as required by 46 CFR 182.720.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Documentation › Certificates/Documents
Issued 2 April 2003
Resolved
Provide evidence that ll crewmembers have passed a chemical test for dangerous drugs as required by 46 CFR 16.210, pre-employment testing requirements.
Action required: 705 - Other - as specified
Resolved 14 April 2003