MAURY USCG vessel records Sign in
← All vessels

HOS HOTSHOT

HOS HOTSHOT is a 2003 offshore supply vessel. The Coast Guard has recorded 13 inspections since 2003, most recently in January 2007, along with 48 deficiencies.

Records from 2003 to 2007. Most recent: inspection, 24 January 2007.

Built
2003
Last inspected
24 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8986183 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB3394
608066
Flag
UNITED STATES
338040000, 369252000 (licence lapsed)
Maury page id
psix-608066

Inspections, by type

Years with a record 5 calendar years (2003–2007)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
338 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
101 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC3667MMSI 338040000 · cancelled · compulsorily equipped · granted 19 January 2005, cancelled 11 June 2007
WDB3394MMSI 369252000 · expired · compulsorily equipped · granted 26 March 2003, cancelled 1 June 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

24 January 2007 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862077
14 July 2006 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2731849
30 May 2006 Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2664267
31 January 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576524
31 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2576536
27 January 2005 Hull Examination · MTSA/ISPS Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2276437
13 September 2004 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2194940
16 August 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2167445
12 July 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2130917
20 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048410
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979390
2 April 2003 Hull Examination · Initial Certification · Construction Oversight · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1758973
10 February 2003 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1809563

Deficiency record · 48

Navigation › Piloting/Steering › Local Notices to Mariners
Issued 14 June 2006 Resolved
Prove charts are corrected utilizing local notice to mariners.
Due 14 July 2006
Resolved 14 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2006 Resolved
Prove operation of stern light.
Due 14 July 2006
Resolved 14 July 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2006 Resolved
Provide 2005 List of Lights.
Due 14 July 2006
Resolved 14 July 2006
Engineering › Steering Gear System › Rudder Stock
Issued 14 June 2006 Resolved
Provide satisfactory rudder stops as per 46 CFR 182.610 (e)
Due 14 July 2006
Resolved 14 July 2006
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2004 Resolved
Demonstrate proper operation of generator overspeed shut downs IAW 46 CFR 183.320
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 16 August 2004
Resolution: Overspeed tests, completed.
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S1, Rev D, Midship Sectoin, approved by ABS Americas on Sep. 18, 2001.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide copy of ABS approval letter dated Sep 18, 2001 for the structural drawing submittals: 305-S1, 305-S3, 305-S10, 305-S11, & 305-S14.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S3, Rev D, Frames B, A, O, 1, approved by ABS Americas on Sep. 18, 2001.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S5, Rev D, Frames 6, 7, 8, & 9, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S6, Rev B, Frames 10, 11, 12, & 13, approved by ABS Americas on Apri 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S8, Rev B, Frames 18 thru 22, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S9, Rev B, Frames 23, 24, 25, & 26, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S12, Rev B, Frames 35, 36, & Transom, approved by ABS Americas on Apr 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide copy of ABS approval letter dated Apr 22, 2002 for the structural drawing submittals: 305-S5, 305-S6, 305-S18, 305-S9, 305-S12, 305-S21, & 305-S23.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No 305-S17, Rev-, Shell Expansion, approved by ABS Americas on Feb 13, 2001.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S20, Rev C, Main Deck House bulkheads, approved by ABS Americas on Jul 9, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide copy of ABs approval letter dated Jul 9, 2002 for Dwg. No 305-S20.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No 305-S21, Rev A, Deck house Top Plating, approved by ABS Americas on April 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S23, Rev B, Pilot [name withheld], approved by ABS Americas on April 22, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-S24, Rev D, Pilot [name withheld], approved by ABS Americas on Oct. 30, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide copy of ABS approval letter dated Oct 30, 3003 for Dwg No. 305-S24.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No. 305-S25, Rev A, Bulwark Details approved by ABS Americas on Sep 10, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide copy of ABS approval letter dated march 26, 2003 for Dwg. No. 305-S25.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No. 305-S26, Rev A, Seachests, approved by ABS Americas on Sep 10, 2002.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide copy of ABS approval letter dated Sep 10, 2002 for Dwg No. 305-S26.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No 305-P11, Rev C, Air Intake diagram, approved by ABS Americas on mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. Sketch, Rev -, Bow Thruster COmpartment Hatch, approved by ABS Americas on Mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No Sketch, Rev. -, Longitudinal Bulkhead 11 ft off centerline, approved by ABS Americas on Mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg. No. Sketch, Rev -, Emergency Escape Hatch, approved by ABS Americas on Mar 26, 2003.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of Diamond/Sea Glaze Dwg. No. 400 F & 106 F, Rev. -, approved by ABS Americas on Mar 10, 2003 with applicable approval letter.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of Freeman Marine Equipment Dwg. No. 2433-0002 & 2424-002, Rev - , approved by ABS Americas on mar 10, 2003 along with applicable approval letter.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Construction/Loadline › Hull
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of EACCO Dwg No. D-001, Rev -, Quick Acting Watertight Door, approved by ABS Americas on Mar 10, 2003 along with applicable approval letter.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 April 2003 Resolved
Provide Coast Guard approved plans with approval letter for fixed fire supproession system as required by 46 CFR 177.202(b)(6)(ii).
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 April 2003 Resolved
Provide Coast Guard approved propulsion control system drawing and approval letter as required by 46 CFR 177.202(b)(6)(iii).
Action required: 705 - Other - as specified
Resolved 1 May 2003
Resolution: Resolved through MSC via e-mail from [name withheld].
Accommodation/Occupational Safety › Ventilation › General
Issued 2 April 2003 Resolved
Provide Coast Guard approved plans and review letters for ventilation arrangement demonstrating compliance with 46 CFR 177.600, 46 CFR 177.620, and other applicable section of 46 CFR Subchapter "T" as required by 46 CFR 177.202(b)(3)(iii).
Action required: 705 - Other - as specified
Resolved 12 July 2004
Resolution: Provided copy of review letters that plans had been approved.
Engineering › Steering Gear System
Issued 2 April 2003 Resolved
Provide Coast Guard approved steering control system drawing and approval letter as required by 46 CFR 177.202(b)(3)(ii).
Action required: 705 - Other - as specified
Resolved 14 April 2003
Resolution: Reviewed and approved by MSC as identified in MSC letter E1-0304692/P006976.
Fire Fighting › Fixed Fire Detection System
Issued 2 April 2003 Resolved
Provide Coast Guard approved plans with approval letter for fire detecting & smoke detecting system as required by 46 CFR 177.202(b)(6)(iii).
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Bilge Water Management System
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-P1, Rev -, Bilge/Ballast Piping as noted on MSC Letter 16710/P006976, Serial:E1-0200394, dtd 2/21/2002.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Steering Gear System
Issued 2 April 2003 Resolved
Provide Coast Guard approved plans with approval letter for hydraulic piping installation as rquired by 46 CFR 177.202(b)(8) and MSC letter 16710/P006976 Serial: E1-0300746 dated Mar 6, 2003.
Action required: 705 - Other - as specified
Resolved 14 April 2003
Resolution: Reviewed and approved by MSC as identified in MSC letter E1-0304692.
Operations/Management › Pollution
Issued 2 April 2003 Resolved
Provide for review a copy of transfer procedures as required by 33 CFR 155.720. LEGACY COMPONENT DESC: Compliance with Transfer Procedures
Action required: 705 - Other - as specified
Resolved 17 April 2003
Lifesaving › Rocket Parachute Flares
Issued 2 April 2003 Resolved
Distress flares and smoke signals shall be stowed in a portable watertight container carried at the operating station or in a pyrotechnic locker secured above the freeboard deck in the vicinity of the operating statoin as required by 46 CFR 180.68.
Action required: 705 - Other - as specified
Resolved 3 April 2003
Electrical › Electric Generation Source (service)
Issued 2 April 2003 Resolved
Provide the OCMI with an identical paper copy of A.K. Suda Dwg No 305-E1, Rev B, Electrical One-Line.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Navigation › Piloting/Steering
Issued 2 April 2003 Resolved
Provide for review current and updated charts and publications as required by 46 CFR 1884.420. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Resolved 3 April 2003
Documentation › Certificates/Documents
Issued 2 April 2003 Resolved
Provide for review radio statoin license and installatoin certificates issued by the FCC, as set for in 47 CFR 80 as required by 46 CFR 184.502. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Resolved 3 April 2003
Engineering › Compressed Air System (start air)
Issued 2 April 2003 Resolved
Provide Coast Guard's copy of A.K. Suda Dwg No. 305-P8, Rev A, Compressed Air, approved by MSC-2 letter 16710/P006976, Serial: E1-0300745 on 3/24/03.
Action required: 705 - Other - as specified
Resolved 7 April 2003
Engineering › Compressed Air System (start air)
Issued 2 April 2003 Resolved
Provide bill of material specification for compressed air system as noted in MSC-2 Letter 16710/P006976, Serial: E1-0300745 dated 3/24/03, comment.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003 Resolved
Provide material spec. documentation of all non-metallic flexible hsoes installed throughout the vessel demonstrating the material meets SAE J-1942 with end fittings meeting SAE J-1475 as required by 46 CFR 182.720.
Action required: 705 - Other - as specified
Resolved 8 April 2003
Documentation › Certificates/Documents
Issued 2 April 2003 Resolved
Provide evidence that ll crewmembers have passed a chemical test for dangerous drugs as required by 46 CFR 16.210, pre-employment testing requirements.
Action required: 705 - Other - as specified
Resolved 14 April 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.