Records from 2016 to 2025. Most recent: inspection, 14 July 2025.
Documentation record
Registered dimensions (L × B × D)26.8 ft × 10.0 ft × 4.9 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS · SOMERSET, MA, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMANCHESTER, MA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
14 July 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8178196
16 July 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7938649
1 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7832248
17 July 2023
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7724188
15 June 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7455539
1 April 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7422233
24 May 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7212966
23 July 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7011950
16 July 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7005315
19 May 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6955828
1 May 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6673680
27 April 2018
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6402948
28 June 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6189296
12 July 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5939554
19 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859114
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Portable fire extinguishers were not being inspected monthly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 14 July 2025
Resolution: Started logging fire extinguisher inspections.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life ring buoy's grab line showed significant UV damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 16 July 2025
Resolution: Operator purchased new life ring buoy for the vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 May 2019
Resolved
Man overboard and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of drill and training and general description of the drill scenario and training topics. Drills shall be conducted at least once each month if reasonable or at least once with in a 3 month period before the vessel gets underway with passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2019
Resolved 1 May 2019
Resolution: Drill conducted during underway portion of inspection and logged.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 May 2019
Resolved
As appropriate for intended voyage a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible; tide tables and current tables, inland navigation rules. Unable to verify correction dates on charts kept onboard. Missing all other publications, provide updated charts and publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 17 May 2019
Resolution: Charts procured and stowed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 May 2019
Resolved
Alcohol testing must be conducted on each individual engaged or employed onboard the vessel who is directly involved in a serious marine incident (SMI). The alcohol testing of each individual must be conducted within 2 hours of a SMI. The means of testing are expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 17 May 2019
Resolution: New alchol test strips procured and made avalible as required.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 May 2018
Resolved
TJT02 Post life jacket donning placards b 18MAY2018; 46CFR185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 30 May 2018
Lifesaving › Lifebuoys › Stowage
Issued 8 May 2018
Resolved
TJT03 Mount life ring and water light by 18MAY2018; 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 30 May 2018
Engineering › Fuel Oil Service System › Hose
Issued 27 April 2018
Resolved
TJT01 replace fuel hoses and fittings with J-1942 by 08MAY2018; 46CFR182.720 (e).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 30 May 2018