MAURY USCG vessel records Sign in
← All vessels

DRAKE

DRAKE is a passenger vessel (inspected). The Coast Guard has recorded 2 inspections since 2003, most recently in May 2004, along with 25 deficiencies — 25 with no resolution recorded —.

Records from 2003 to 2004. Most recent: inspection, 11 May 2004.

Built
Not recorded
Last inspected
11 May 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

608299
Flag
UNITED STATES
—
Maury page id
psix-608299

Inspections, by type

Years with a record 2 calendar years (2003–2004)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

11 May 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2064956
15 January 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1738040

Deficiency record · 25

Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 15 January 2003 No resolution recorded
Provide approved drawings for intended modifications, arrangements, capacities for the foreward and aft accommodation spaces that meet recognized standards as listed in T Boat Plan Review Compliance Checklist Including two means of escape from each accommodation space operable from both sides.
Action required: 705 - Other - as specified
Stability › Watertight Integrity › General
Issued 15 January 2003 No resolution recorded
Make bulkheadsbetween accommodation spaces engineroon vaportight IAW 46 CFR 177.405(c)
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 15 January 2003 No resolution recorded
Submit plans for A/C installed ventilation IAW 46 CFR 177.600 for approval .
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 15 January 2003 No resolution recorded
Install deck/hand rails as per approved drawing # 2001-70-02 and IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Stability › Watertight Integrity › General
Issued 15 January 2003 No resolution recorded
Ensure all watertight doors, hatches and companion way openings comply with 46 CFR 177.330 and 177.360.
Action required: 705 - Other - as specified
Stability › Watertight Integrity › General
Issued 15 January 2003 No resolution recorded
Ensure openings inside the vessel below the Load Water Line (LWL) have positive action valves installed IAW 46 CFR 179.360
Action required: 705 - Other - as specified
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 15 January 2003 No resolution recorded
Install lifesaving equipment for approved route and conditions IAW180.64 and 180.70-210
Action required: 705 - Other - as specified
Fire Fighting › Fire Pumps › Arrangement
Issued 15 January 2003 No resolution recorded
Submit plans for approval for fire fighting pump, piping and hose arrangement. IAW 46 CFR 181.300
Action required: 705 - Other - as specified
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 January 2003 No resolution recorded
Service installed CO2 Fire Fighting system in engineroom IAW 46 CFR 181.400.
Action required: 705 - Other - as specified
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 15 January 2003 No resolution recorded
Provide proof that engine room CO2 coverage is adequate as required for space serviced IAW 46 CFR 181.410 If nozzle arrangement needs modifying due to new generator install, submit plans for approval prior to installation.
Action required: 705 - Other - as specified
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 15 January 2003 No resolution recorded
Provide portable fire extinguishers as required IAW 46 CFR 181.500(a)
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 January 2003 No resolution recorded
Provide approved plan for electrical distribution and arrangement IAW 183.210 - 181.432
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Ventilators
Issued 15 January 2003 No resolution recorded
Provide approved drawing of new galley installation and arrangement for marine use IAW 46 CFR 184.200
Action required: 705 - Other - as specified
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 January 2003 No resolution recorded
Provide Radar for approved route and conditions IAW 46 CFR 184.404
Action required: 705 - Other - as specified
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 15 January 2003 No resolution recorded
Provide electronic positive fixed device for approved route IAW 46 CFR 184.410
Action required: 705 - Other - as specified
Communications › Internal Communications System › Portable Radios
Issued 15 January 2003 No resolution recorded
Provide internal communication system IAW 46 CFR 184.602 and Public Address system IAW 46 CFR 610
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System › Not Installed
Issued 15 January 2003 No resolution recorded
Provide a bilge system line drawing as required by 46 CFR 177.202(b) Include pump capacities, pipe sizes, strainers, valves and check valves.
Action required: 705 - Other - as specified
Engineering › Electric Propulsion System › Switch
Issued 15 January 2003 No resolution recorded
Relocate battery and battery chargers, spark producing devices must be mounted above bilges, IAW 46 CFR 182.410(a) LEGACY COMPONENT DESC: Batteries
Action required: 705 - Other - as specified
Engineering › Fuel Oil Service System › Piping
Issued 15 January 2003 No resolution recorded
Provide fuel system drawing, to include tank, valves, hoses and piping IAW 46 CFR 177.202, 182.720 and SAE J1942
Action required: 705 - Other - as specified
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 January 2003 No resolution recorded
Provide steering gear system drawing including hose types, as required by 46 CFR 177.202 and 182.610
Action required: 705 - Other - as specified
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 15 January 2003 No resolution recorded
Install fuel tank vent closures IAW 46 CFR 182.465
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Door
Issued 15 January 2003 No resolution recorded
Provide 6" coaming on all weathertight doors IAW 46 CFR 179.360(d)(1)
Action required: 705 - Other - as specified
Stability
Issued 15 January 2003 No resolution recorded
Conduct stability test after modifications to vessel are complete.
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 15 January 2003 No resolution recorded
Show proof that mattress meets standard IAW 46 CFR 177.405(g)
Action required: 705 - Other - as specified
Fire Fighting › Ventilation Systems › Ducts
Issued 15 January 2003 No resolution recorded
Ensure lazarette ventilation is IAW 46 CFR 182.470
Action required: 705 - Other - as specified

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.