MAURY USCG vessel records
← All vessels

AEC DILIGENCE

AEC DILIGENCE is a 2002 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in August 2019, along with 2 deficiencies and 2 operational controls.

Records from 2016 to 2019. Most recent: inspection, 18 August 2019.

Built
2002
Last inspected
18 August 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 August 2019
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9249025
608754
Flag
BAHAMAS, THE
Maury page id
psix-608754

Documentation record

Tonnage as PSIX records it19882 - Convention (Subpart B), Gross Ton
10780 - Convention (Subpart B), Net Ton
39650 - Displacement, Metric Ton
32258 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

18 August 2019 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6779431
11 February 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6353184
2 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6348296
31 January 2018 COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6344023
26 January 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6344570
1 June 2016 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5884315

Deficiency record · 2

Fire Fighting › Firemans Outfit › Lifeline
Issued 2 February 2018 Resolved
0735-FIREMANS OUTFITS- FOR EACH APPARATUS A FIRE PROOF LIFELINE OF SUFFICIENT LEANGTH AND STRENGTH SHALL BE PROVIDED. THE LIFELINES ON BOARD WERE NOT FIREPROOF.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 March 2018
Resolved 7 February 2018
Resolution: New fireproof lifelines were procured and delivered to the vessel.
Construction/Loadline › Structures › Door
Issued 1 June 2016 Resolved
1270 - Doors - PSCO observed on the bridge an A-0 fire door to the "Elect Equip Room" which was missing its handle and lock. In this condition, the fire door was not able to be latched shut and there were clear openings where the handle and lock were missing. Crew installed new handle and lock prior to the end of the exam. SOLAS II-2/14.2.1.1. 10c.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: On the spot correction prior to the end of the exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.