Records from 2008 to 2026. Most recent: inspection, 22 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 21
22 April 2026
Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8354119
20 May 2025
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8140247
21 April 2025
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8110267
10 January 2025
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8060745
22 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7899533
13 February 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7864907
15 February 2023
Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7637188
7 February 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7633478
25 February 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401858
11 March 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7155154
26 January 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7131195
21 February 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6912938
6 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637270
14 January 2019
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6609900
24 July 2018
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 6491478
23 February 2018
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6360600
30 March 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6115338
16 February 2017
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6089785
26 January 2017
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6077913
16 March 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5835031
18 February 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817897
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 March 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel's Radiotelephony certificate was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 20 March 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 March 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel's paper charts were were published in 2020 and do not have the up-to-date corrections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 20 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2021
Resolved
Ring life buoy shall be maintained in accordance with manufactures instructions. Life buoy was beyond the service life. Replace life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2021
Resolved 12 April 2021
Resolution: Owner purchased new life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2021
Resolved
Life ring floating light battery was expired. Replace light battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2021
Resolved 12 April 2021
Resolution: Vessel owner replaced life ring water light with new battery, with experation of 12/22
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 April 2021
Resolved
Alcohol test strips were expired. Replace alcohol test strips.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 14 April 2021
Resolution: Received documentary evidence of alcohol test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 March 2020
Resolved
Vessels distress signals were expired.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2020
Resolved 23 March 2020
Resolution: Vessel purchased new distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 March 2020
Resolved
Life floats had deteriorated lifeline/penant attachment straps. Vessel was told to reach out to the manufacturer to see if there is anything they can do to repair the life floats and if so, procedures on how to repair. If the manufacture does not allow repairs to be made the vessel will need to purchase new life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2020
Resolved 4 May 2020
Resolution: Vessel had both life floats repaired by the manufacturer.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 March 2018
Resolved
Installed fire fighting system auto shutdown for both main diesel engines inoperable
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2018
Resolution: Repaired installed fire fighting system auto shutdown; verified operation.
Engineering › Fuel Oil Service System › Valve, Control
Issued 5 March 2018
Resolved
STBD main engine fuel shut-off valve inoperable
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2018
Resolution: Repaired stbd main engine fuel shut off.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 March 2018
Resolved
No emergency radio broadcast placard near VHF radio
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 8 March 2018
Resolution: Installed emergency radio broadcast placard.
Communications › Radio Communications › EPIRB
Issued 5 March 2018
Resolved
Monthly EPIRB tests not conducted monthly
Condition: Improper/Lack of Maintenance
Due 5 March 2018
Resolved 5 March 2018
Resolution: Resolved on cite
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 March 2018
Resolved
ALCO testing strips are expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 8 March 2018
Resolution: Purchased new ALCO strips.
Communications › Radio Communications › EPIRB
Issued 16 March 2017
Resolved
EPIRB battery expired and did not operate when tested. EPIRB battery must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 16 March 2017
Resolution: Captain purchased a new EPIRB.
Communications › Radio Communications › EPIRB
Issued 16 March 2017
Resolved
Register EPIRB with NOAA before installation of new EPIRB. Provide proof of registration. Site 47 CFR 80.1061
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 16 March 2017
Resolution: Once Captain purchased new EPIRB he registered it in front of attending MI.
Lifesaving › Lifefloat › Painter
Issued 16 March 2017
Resolved
Two painter lines serving life floats are deteriorated. Painter lines shall be at least 100 feet in length and have a breaking strength of at least 1,500 lbs., be of a dark color if synthetic or a type certified to be resistant to deterioration from ultra violet light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 16 March 2017
Resolution: Captain replaced the wasted painter line with new.
Lifesaving › Lifefloat › Float-free Link
Issued 16 March 2017
Resolved
The float free links serving the life floats shall be secured to the painter at one end and the vessel on the other end. MI's observed both life float painters were attached to the float free links at the same end attached to the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 16 March 2017
Resolution: Captain attached the float free link correctly.
Lifesaving › Lifefloat › Lifeline
Issued 16 March 2017
Resolved
Lifelines serving the Stbd side life float are deteriorated, requiring lifelines and pendants to meet the requirements in subpart 160.010 of this chapter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 30 March 2017
Resolution: Replaced lifelines.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 March 2017
Resolved
The floating water lights serving the life floats must be attached around the body of the life float. The lanyard shall be at least 18 feet in length.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 30 March 2017
Resolution: Properly attached floating light to life float and lanyard is the required length.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 March 2016
Resolved
Fuel vent pipe terminated in space. Discharge end of fuel vent pipe must terminate on the exterior of the vessel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 16 March 2016
Resolution: New fuel vent piping was installed, to terminate through both sides of the vessel's hull.
Navigation › Piloting/Steering › Marine Charts
Issued 1 March 2016
Resolved
Charts onboard were outdated. Provide updated or corrected charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: New Charts were provided
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 March 2016
Resolved
Retro reflective tape was missing from outside of ring. Replace with approved tape
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: New Retro Reflective tape was applied
Lifesaving › Lifefloat › Markings
Issued 1 March 2016
Resolved
Life float's retro tape was damaged/missing in places. Replace with approved tape.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: New Retro reflective tape was applied
Lifesaving › Lifefloat › Paddle
Issued 1 March 2016
Resolved
The paddles on the port life float were damaged. Replace paddles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: New paddles were provided
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 March 2016
Resolved
Captain did not have his original MMC onboard. Provide original credentials while boat is operating.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: Credentials were placed onboard
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 March 2016
Resolved
Two dead ended wires found on STBD side of lazarette space. Remove dead ended wires or properly cap and enclose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: Dead end wires were removed
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 March 2016
Resolved
Electrical wires were not properly supported and laying in the bilge by rudder posts in lazarette. Properly secure cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: Wires were properly secured
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 March 2016
Resolved
A bundle of cables/wires in the forward part of the lazarette space are only supported by zip ties. Properly support wires/cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: Wires were found properly supported
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 March 2016
Resolved
A ground cable is not installed on the PORT side of the lazarette. Properly attach gound wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 16 March 2016
Resolution: Ground wires properly attached