← All vessels
SEA DREAMS II
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Oceania District (CGD-O) · Other hulls named SEA DREAMS II
SEA DREAMS II is a 2003 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2003, most recently in September 2025, along with 138 deficiencies and 1 operational control.
Records from 2003 to 2025. Most recent: inspection, 12 September 2025.
- Built
- 2003
- Last inspected
- 12 September 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 138 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1137898
WDD8858
608989
Flag
UNITED STATES
367303660
Maury page id
psix-608989
Inspections, by type
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)37.8 ft × 14.8 ft × 5.6 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ5223MMSI 367303660 · active · compulsorily equipped · granted 25 July 2025, expires 25 July 2035 · licensed under a name not among this hull’s recorded names (not shown)
WDD8858MMSI 367303660 · cancelled · compulsorily equipped · granted 16 May 2017, cancelled 23 July 2025
WDB3546MMSI 366888380 · expired · compulsorily equipped · granted 9 April 2003, cancelled 15 June 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 34
12 September 2025
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8242002
23 July 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8188203
23 October 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855617
10 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855603
27 February 2023
Deficiency Check · Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7620000
18 October 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7579845
16 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7452048
25 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7207033
27 October 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7085569
21 October 2020
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082001
11 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6977880
22 May 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6676329
30 October 2018
Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6571610
15 March 2018
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6369142
23 January 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6342510
20 April 2017
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6128565
11 October 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6020210
7 April 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5849533
19 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4819102
16 July 2012
Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4380850
12 June 2012
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4341963
15 April 2009
Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3453511
17 April 2008
COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3184974
24 September 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3065785
29 June 2007
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2977937
29 June 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2989558
21 August 2006
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2750195
11 June 2006
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2678949
16 June 2005
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2548989
8 April 2005
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2548962
17 May 2004
Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2070799
19 February 2004
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2009518
27 May 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1825777
2 April 2003
Construction Oversight · Simplified Stability Test · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1767062
Deficiency record · 138
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 July 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station, (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines. The port engine discharge alarm did not indicate power or produce a visible and audible indicator of discharge. Repair and prove proper operation in the presence of the attending marine inspector.
46 CFR 181.420(b)
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 July 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Man overboard drill not conducted. Conduct man overboard drill prior to carrying passengers to the satisfaction of the attending marine inspector.
46 CFR 176.808(g)
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 July 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Fire drill not conducted. Conduct fire drill prior to carrying passengers to the satisfaction of the attending marine inspector.
46 CFR 176.810(d)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 July 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry, (1) Six hand red flare; and (2) Six hand orange smoke distress signals; or substitutions as per 46 CFR 180.68(c). Vessel had three hand red flares and three hand orange smoke. Provide the correct number of distress signals in accordance with the regulations to the satisfaction of the attending marine inspector.
46 CFR 180.60(a)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2025
Resolved
The platform must be suspended from the body of the float by a net or an equivalent arrangement, which when fully extended, holds the top of the platform approximately 36 in. below the center of the float body. Life float stainless steel platform frame broken. Repair to the satisfaction of the attending marine inspector.
46 CFR 160.027-3(f)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. One paddle broke. Replace with a paddle of at least 4 feet in length to the satisfaction of the attending marine inspector.
46 CFR 180.175(f)(2)
46 CFR 180.175(f)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2025
Resolved
Pendants must be fitted approximately 18 in. apart around the outside of each buoyant apparatus. Each pendant must be made up in a hank, and the hank secured by not more than two turns of light twine. Life float pendants were not made up in a hank or secured by twine. Make pendants as described by the regulation to the satisfaction of the attending marine inspector.
46 CFR 160.010-4(g)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. No emergency instructions onboard or posted at the operating station. Provide emergency instructions with the recommended format as prescribed by 46 CFR 185.512, to the satisfaction of the attending marine inspector.
46 CFR 185.510(a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a highwater level in each of the following normally unmanned spaces, a space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. The port side tank space high water visual alarm illuminates when the port engine space high water alarm is activated and the engine space high water visual alarm does not illuminate when activated. Make so the highwater alarm activated for that space illuminates to the satisfaction of the attending marine inspector.
46 CFR 182.530(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2025
Resolved
Independent fuel tanks must be located and installed as described in this paragraph (b) All fuel tanks must be electrically bonded to a common ground. The port and starboard fuel tanks are not bonded. Bond the fuel tanks as described by the regulation to the satisfaction of the attending marine inspector.
46 CFR 182.440(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that, (1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. The port forward space, port tank space, and port engine room submersible electric bilge pumps are not UL 1113 approved. Provide UL 1113 approved bilge pumps for these spaces and prove proper operation to the satisfaction of the attending marine inspector.
46 CFR 182.520(e)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2025
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Fuse blocks and fuses are of the blade type. Replace fuse holder and fuses to UL approved cartridge type to the satisfaction of the attending marine inspector.
46 CFR 183.380(l)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2025
Resolved
Each circuit breaker must meet UL 489 or other standard specified by the Commandant and be of the manually reset type designed for; (1) Inverse time delay; (2) Instantaneous short circuit protection; and (3) Switching duty if the breaker is used as a switch. The Blue Seas surface mount circuit breakers in the port and starboard engine spaces are not UL 489 approved. Replace circuit breakers with UL 489 of the same amperage to the satisfaction of the attending marine inspector.
46 CFR 183.380(m)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either, (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Starboard tank space bilge cable connections made by twisting the cable through and around a ring connector inside the enclosure. Make connection using a method as described above to the satisfaction of the attending marine inspector.
46 CFR 183.340(g)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to, (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; and (c) Minimize accidental personnel contact with energized parts. Rocker switch wired tied on outboard amidship hull in tank space is designed to be in an enclosure resulting in the electrical terminals being exposed. Mount switch in the proper enclosure to the satisfaction of the attending marine inspector.
46 CFR 183.200(b)(c)
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 July 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date, U.S. Coast Pilot or similar publication. Coast Pilot expired. Provide adequate and up-to-date or extract of the Coast Pilot for the vessel’s operating area to the satisfaction of the attending marine inspector.
46 CFR 184.420(a)(2)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. (1) The starboard forward space bilge pump discharge hose is kinked potentially compromising the pump’s ability to dewater the space; (2) The port engine crankcase breather hose is almost cut in half permitting these vapors to escape into the engine space; (3) Port engine space automatic float is not mounted potentially preventing the pump from operating if the space is flooded; and (4) The sewage macerator discharge hose is kinked and burned. Repair or replace all the above to the satisfaction of the attending marine inspector.
46 CFR 176.830(a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2025
Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. No supervisory training conducted. Provide objective evidence to the satisfaction of the attending marine inspector that an additional 60 minutes of supervisory training was conducted.
46 CFR 16.401(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 October 2024
Resolved
A hatch exposed to the weather must be watertight. Gasket material for the forward port and forward starboard hatches were deteriorated.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 July 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for EPIRB expired. Install new hydrostatic release. Vessel restricted to Lakes, Bays, and Sounds route.
46 CFR 176.808(a)(5)
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 July 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for life float expired. Install new hydrostatic release.
46 CFR 176.808(a)(5)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2024
Resolved
Child size life jackets equal to 10% of the number of persons permitted on board must be provided. Vessel needs to provide required number of child size life jackets. Vessel restricted to carrying 4 persons weighing less than 90 pounds.
46 CFR 180.71
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 10 July 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel's alcohol testing strips were expired. Provide new alcohol testing strips.
46 CFR 4.06-15 (a)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 July 2024
Resolved
Each vessel must be equipment with at least two operable portable battery lights. Vessel did not have portable battery lights. Provide 2 portable battery lights.
46 CFR 183.430
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 July 2024
Resolved
Lifelines and pendants must be as furnished by the manufacturer. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 February 2023
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Vessel had approximately 2 gallons of diesel fuel in the port engine room bilge due to a previous leaky hose on the discharge end of the fuel filter. Remove standing fuel from port engine room bilge.
46CFR176.830(b)
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 February 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Both ventilation duct closures in the starboard engine room, and the aft ventilation duct closure in the port engine room did not close completely. Make arrangements to ensure complete closure of vents.
46CFR 182.465(h)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 February 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Starboard engine room high water level alarm light at operating station is not operational. Fix light.
46CFR182.530
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 February 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket had a broken buckle. Provide additional life jacket in serviceable condition. Reduce passenger count by one. Total passenger count is 41 persons until rectified.
46CFR180.71
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023
Resolved
A portable hand bilge pump must be capable of pumping water. Vessel did not have portable hand bilge pump. Acquire new portable hand bilge pump.
46CFR182.520(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. No separation between adult and child life jackets. Provide proper stowage of life jackets.
46CFR180.78(a)(5)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 27 February 2023
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Neither the crew member nor the master onboard had a valid radio operator permit. Provide marine radio operator permit.
47CFR80.158(e)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 27 February 2023
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have company’s policy regarding drug and alcohol use onboard. Place company’s policy onboard vessel.
46CFR16.401(a)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 May 2022
Resolved
Port forward compartment hull wasted IWO the bilge pump through hole valve. Provide repair proposal for approval to the attending Marine Inspector.
46 CFR 176.802(a)(2)
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 May 2022
Resolved
Port and STBD aft manual exhaust vent closure devices fail to seal the vent opening. Prove proper operation to the attending Marine inspector.
46 CFR 182.465(h)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 May 2022
Resolved
Missing required distress flares for a LBS + LC route. Provide required number and type of distress flares to the satisfaction of the attending Marine Inspector.
46 CFR 180.68
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 May 2022
Resolved
Stern navigation light inoperable and required for to comply with rules concerning lights and shapes (daylight/restricted visibility; other circumstances). Prove proper operation of the stern navigation light to the satisfaction of the attending Marine Inspector.
33 CFR 83.23
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 May 2022
Resolved
No means of making an efficient sound signal for a vessel of less than 12 meters in length. Provide efficient sound signal to the satisfaction of the attending Marine Inspector.
33 CFR 83.33(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2022
Resolved
Life jacket storage containers on upper deck not marked with number and identification of the items stowed inside and their size. Properly mark adult and child size life jacket stowage.
46 CFR 185.604(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present to prevent the passage of vapors. The starboard aft bulkhead penetration freely communicates between the engine room and fuel tank space. Provide a proper seal to prevent the passage of vapors.
46 CFR 177.405(e)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 May 2022
Resolved
Port mid space flush deck QAWTS missing gasket. Install gasket.
46 CFR 179.360
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. STBD engine room battery positive bus missing protective cover. Provide cover.
46 CFR 183.200(c)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 May 2022
Resolved
Each buoyant apparatus must have Type II retroreflective material that extends from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. Life float had worn retroreflective material. Renew.
46 CFR 160.010-4(p)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022
Resolved
Where a flexible vent pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Port fuel tank vent hose application for wet exhaust and STBD fuel tank vent house application for water. Replace with correct SAE J1942 qualified hoses for marine application or SAE J1527 marine fuel hoses.
46 CFR 182.450(g)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 May 2022
Resolved
Each vessel must be equipment with at least two operable portable battery lights. Vessels missing required portable lights. Provide.
46 CFR 183.430
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 May 2022
Resolved
Missing Coast Guard Light List. Provide.
46 CFR 184.420(a)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2022
Resolved
A positive shutoff valve is installed at the hull penetration. Electrical submersible bilge pump for the port mid space positive shutoff valve is not installed at the hull penetration. Relocate valve as close as possible to the hull penetration.
46 CFR 182.520(e)(7)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2022
Resolved
Rigid nonmetallic materials (plastic) are not authorized in vital systems which are vital to a vessel's survivability and safety, i.e. Bilge system. Replace PVC elbow in port mid space bilge piping.
46 CFR 182.710
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the starboard forward anchor locker electric bilge pump. Prove proper operation of the bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery. The port PSS bellow was not compressed allowing water to enter the vessel. Compress PSS bellows IAW the manufacturers bellow compression chart.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 May 2021
Resolved
The identification tag for the life float indicating the proper strength of the link was missing. Replace float-free link with one with an identification tag IAW 46 CFR 187.137(b)(2).
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 May 2021
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Three hand orange smoke distress signals are expired and three red hand held distress signals are expired. Vessel restricted to a Lakes/Bays/Sounds route or 30 min runs until correct number of distress flares for limited coastwise route are provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 May 2021
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The EPIRB bracket is incorrect for the 2830 Globalfix V4 Gps EPIRB. Install correct bracket for the above EPIRB to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Provide a divider to separate the adult life jackets from the child life jackets in the port flying bridge storage container.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Submersible electric bilge pumps are not UL1113 approved. Replace and install IAW manufacture instructions UL1113 approved submersible electric bilge pumps to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The Starboard forward, port engine room, and starboard amidship visual indicators for the automatic bilge pumps are inoperable. Prove proper operation to the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 May 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first-aid kit burn treatment gel, and anti-septic swabs are expired. the aspirin and eyewash are missing. Replace/add expired and missing contents to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 May 2021
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Mark life float paddles with vessel name to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 May 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible, U.S. Coast Pilot or similar publication; Coast Guard Light List; and Tide tables. Provide extracts from the publications listed above for the areas to be transited to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that a positive shutoff valve is installed at the hull penetration. The bilge overboard discharge valve at the hull penetration for the port forepeak compartment is inoperable. Replace and prove proper operation to the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2021
Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. There are two wires under the helm on the starboard side and a power terminal at the junction box in the amidships compartment that have exposed, unsecured, leads. All three power cables shall be properly terminated or secured to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 May 2021
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A light to indicate discharge and an audible alarm that sounds upon discharge. The audible and visual alarms for the port engine room FireBoy is inoperable. Correct to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2021
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of vessels fire buckets had a capacity of 5 gallons and missing lanyard. Drill holes to 2 1/2 gallons and attach lanyard that reaches water when on bow.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 25 May 2021
Resolved
EAP training program: An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide proof of training program and documentation of training given to crewmembers and supervisory personal to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 May 2021
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No record of recent abandon ship, man overboard drills or training available. Conduct the above training and document for review by the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2021
Resolved
The following tests and inspections must be carried out weekly on a vessel: each survival craft must be visually inspected to ensure its readiness for use. No record of life float weekly inspections documented. Perform life float weekly inspection and document for review by the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2021
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented, as applicable. No record of monthly EPIRB test documented.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. While conducting sea trials following drydock the vessels starboard engine overheated causing the Fireboy system to activate. Demonstrate proper operation of starboard engine to the satisfaction of the attending USCG marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 October 2020
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing propulsion machinery. Fireboy for the starboard engine has been energized and shall be replaced. Provide a certified technician service report & demonstrate all shutdowns, alarms, and overrides to the attending USCG marine inspector.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 June 2020
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing LAT/LONG for DSC operation.
47 CFR 80.905
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Vessel has audible alarm but no visual indicator for high level alarms.
46 CFR 182.530 (a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2020
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel must provide separate indicator for port forward void.
46 CFR 182.530 (c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2020
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing systems is installed must have the following equipment at the operating station: A light to indicate discharge. Vessels discharge lights inoperable.
46 CFR 181.420 (b) (1)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 May 2019
Resolved
46 CFR 160.010-4(g)(i):
Pendants on Buoyant Apparatus shall be synthetic line or webbing type approved by its manufacturer as ultra-violet light resistant, or it is pigmented in a dark color in length of at least 12 ft long and 1/4 inches in diameter. Pendants were brittle and falling apart.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 May 2019
Resolved
46 CFR 160.050-3(c):
Grab line shall be 3/8 inch diameter suitable buoyant type synthetic material having a minimum breaking strength of 1350 pounds and resistant to deterioration from ultraviolet light. Grab lines were brittle and falling apart.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2019
Resolved
46 CFR 182.530(a):
On a vessel of at least 26 ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each compartment. No visual alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 May 2019
Resolved
46 CFR 183.430:
Each vessel must be equipped with at least two operable portable battery lights. Two lights were not working.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 May 2019
Resolved
46 CFR 176.802(a):
Vessel ready for inspections of the hull structures. Fractured weld in transverse deck support frame below in
port fwd compartment.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 15 March 2018
Resolved
Provide label for lifejacket stowage container that meets the requirements of 46 CFR 185.604(f)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 March 2018
Resolved
Get fire extinguishers located at entrances to part and starboard engine rooms serviced IAW 46 CFR 176.810 (b)(1)
Communications › Radio Communications › EPIRB
Issued 20 April 2017
Resolved
EPIRB battery expired January 2017. Replace battery or provide new EPIRB. Vessel prohibited from operating more than 3 miles from shore until EPIRB battery is replaced or new EPIRB is provided. 46CFR180.64
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 20 April 2017
Resolved
STBD fireboy bottle is corroded/wasted. Replace fireboy bottle and prove proper operation in the presence of CG inspector 46 CFR 147.65
Engineering › Bilge Water Management System › Pump
Issued 20 April 2017
Resolved
Provide visual indicators for all bilge pumps at the operating station and prove proper operation in the presence of a CG inspector 46CFR 182.530(c)
Lifesaving › Hand Flares › Quantity
Issued 20 April 2017
Resolved
Provide 6 red and 6 orange distress signal flares 46CFR180.68
Fire Fighting › Fire Bucket › Quantity
Issued 20 April 2017
Resolved
Provide 3 fire buckets. 46CFR181.610 (corrected on the spot)
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 20 April 2017
Resolved
Provide log for monthly maintenance and inspection of survival craft. 46CFR185.722
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 20 April 2017
Resolved
Provide FCC Radio Operator Permit 46CFR184.502 - 47CFR 80
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2017
Resolved
Provide current navigation chart, current tide tables/currents and coast pilot. 46CFR184.420
Navigation › Piloting/Steering › Marine Charts
Issued 7 April 2016
Resolved
Provide updated navigation charts.
Documentation › Logs/Records › Logbook (official)
Issued 7 April 2016
Resolved
Add an entry for survival craft maintenance/service into inspection log.
Documentation › Markings/Placards › Warning Signs
Issued 7 April 2016
Resolved
Provide an emergency broadcast placard.
Lifesaving › Lifefloat › Pendant
Issued 7 April 2016
Resolved
Replace lifesaving pendant line found deteriorated in life float.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 April 2016
Resolved
Replace retroreflective tape on 02 adult life jackets.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2016
Resolved
Provide specific indicators for bilge alarms in order to distinguish the alarms coming from aft and forward voids. Properly label them at the pilot house.
Communications › Radio Communications › EPIRB
Issued 19 March 2014
Resolved
EPIRB registration with NOAA was out of date
Engineering › Bilge Water Management System › Pump
Issued 19 March 2014
Resolved
Bilge pumps in forward spaces of both hulls were not mounted. Bilge pump in forward space of port hull did not operate.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 March 2014
Resolved
Could not provide servicing certificate for 4 fire extinguishers and 2 Fireboy fixed fire extinguishing systems.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 March 2014
Resolved
retroreflective material was weathered and not reflective
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 March 2014
Resolved
weathered retroreflective material on extra ring lifebuoy, attached line did not float
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 March 2014
Resolved
aspirin was expired
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 July 2012
Resolved
Not onboard
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 July 2012
Resolved
Not onboard
Fire Fighting › Fire Bucket › Quantity
Issued 16 July 2012
Resolved
Not Onboard
Fire Fighting › Fire Bucket › Stenciling
Issued 16 July 2012
Resolved
No buckets stenciled
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 16 July 2012
Resolved
Both Port and Starboard Engine Room intake louvers do not close when activated.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 July 2012
Resolved
Starboard aft fire extinguisher was discharged for no reason.
Engineering › Bilge Water Management System › Piping
Issued 16 July 2012
Resolved
Forward port void bilge piping broke at the overboard piping. Unknown as to specific reason why piping broke.
Engineering › Bilge Water Management System › Not Operational
Issued 16 July 2012
Resolved
Both forward port and starboard voids as well as both port and starboard engine room compartments bilge high alarms did not work.
Engineering › Bilge Water Management System › Not Operational
Issued 16 July 2012
Resolved
Forward staboard void as well as both port and starboard engine room compartments bilge pumps did not work.
Lifesaving › Launching Appliances › Release Mechanism
Issued 16 July 2012
Resolved
Hydrostatic release for EPIRB needs replacing
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 July 2012
Resolved
Approximately 30 feet of line instead of 60 feet installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 July 2012
Resolved
Battery for Life float is present, but out of date.
Lifesaving › Hand Flares › Quantity
Issued 16 July 2012
Resolved
Ship has 8 flares but within one month of expiration.
Operations/Management › Drills/Instruction › Fire
Issued 16 July 2012
Resolved
No drills or epirb tests recorded in ships log.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 July 2012
Resolved
Service report is not provided to inspectors
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 July 2012
Resolved
Failure to be in full compliance with COI while carrying passengers
Stability › Incline Test › General
Issued 12 June 2012
Resolved
Vessel completed re-power and exceeded the maximum 2% lightship weight change. Vessel required to complete new stability test.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 April 2009
Resolved
Found all drive shaft water-bearings worn beyond 50%, renew same.
Documentation › Markings/Placards › Capacity Marking
Issued 15 April 2009
Resolved
Found upper-deck passenger label/placard missing. Properly label same prior to carrying passengers.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 9 July 2007
Resolved
Provide Emergency Instructions and Emergency Broadcast Placards. 46CFR185.510 & 46CFR184.506
Engineering › Bilge Water Management System › Pump
Issued 9 July 2007
Resolved
Provide a portable bilge pump (5gpm). 46CFR176.804
Lifesaving › Lifebuoys › Serviceable
Issued 29 June 2007
Resolved
Replace or repair both ring life buoys (only one with line and light required). Both are cracked, exposing the inside foam.
Lifesaving › Lifefloat › Float Free
Issued 29 June 2007
Resolved
The installed lifefloat is not float-free. Provide proper installation for the lifefloat.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 29 June 2007
Resolved
Provide a total of (6) orange smoke signals. Found (3) onboard.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 29 June 2007
Resolved
Replace the light cover missing over the light in the port aft engine compartment.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 June 2007
Resolved
Provide current tide table and light list for the vessel's area of operations. 46CFR 184.420.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2006
Resolved
Prove proper operation of anchor light
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 June 2006
Resolved
Provide copy of 2005 MIS report
Operations/Management › Drills/Instruction › Fire
Issued 11 June 2006
Resolved
Conduct drills in the presence of a CG Marine Inspector
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 June 2005
Resolved
Obtain valid copy of new COD and retain onboard
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 June 2005
Resolved
Prove 100% training of crew for every quarter.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2005
Resolved
Obtain new iodine, eyewash, and burn gel for first aid kit.
Construction/Loadline › Hull
Issued 17 May 2004
Resolved
Submit repair proposal to weld the two ¾ inch holes in the forward stbd compartment. LEGACY COMPONENT DESC: Side Shell
Documentation › Logs/Records › Drug Test Records
Issued 17 May 2004
Resolved
Provide documentation that the company is participating in a chemical testing program.
Operations/Management › Drills/Instruction
Issued 2 April 2003
Resolved
Conduct crew drills prior to operating in Hawaii
Operations/Management › Port and Waterways Safety
Issued 2 April 2003
Resolved
Conduct new to zone inspection prior to carrying passengers.
Documentation › Manuals/Policy Documentation
Issued 2 April 2003
Resolved
Obtain and carry tide tables for area of operations.